- 05000316/LER-1981-061, Forwards LER 81-061/03L-0 + (ML20033C890)
- 05000316/LER-1981-061-03, /03L-0:on 811030,during Reactor Startup at 20% Power,Steam Generator Flow 3 Channel 1 Failed Low.Caused by Air Trapped in Sensing Lines Causing Incorrect Transmitter Output.Sensing Lines Blown Down + (ML20033C892)
- ML20033C893 + (ML20033C893)
- 05000285/LER-1981-010, Forwards LER 81-010/03L-0 + (ML20033C894)
- ML20033C896 + (ML20033C896)
- 05000285/LER-1981-010-03, /03L-0:on 811027,D/LC-383-1 Left & Right Switches & D/LC-383-2 Left & Right Switches Found Out of Setpoint Tolerances.Caused by D Channel Level Switches Drifting Out of Calibr for Unknown Reasons.Switches Recalibr + (ML20033C898)
- ML20033C901 + (ML20033C901)
- IR 05000245/1981013 + (ML20033C903)
- ML20033C905 + (ML20033C905)
- ML20033C906 + (ML20033C906)
- 05000316/LER-1981-060, Forwards LER 81-060/03L-0 + (ML20033C908)
- ML20033C910 + (ML20033C910)
- A02027, Responds to NRC Re Violations Noted in IE Insp Rept 50-245/81-13.Corrective Actions:Average Control Rod Insertion Times Will Be Deleted from Revised Sp 1051 (Control Rod Scram Time Test) + (ML20033C911)
- 05000316/LER-1981-060-03, /03L-0:on 811031,during Normal Operation,Failed Proximity Switches Noted for Stop Valves a & D for Trains B & A,Respectively.Cause Unknown Because Unit Cannot Be Disassembled.Switches Replaced + (ML20033C912)
- ML20033C913 + (ML20033C913)
- ML20033C914 + (ML20033C914)
- ML20033C915 + (ML20033C915)
- ML20033C916 + (ML20033C916)
- GO2-81-048, Interim Deficiency Rept Re out-of-calibr Torque Wrenches & Inability of Contractor Installation Procedure to Identify Which Safety or nonsafety-related Items Wrenches Used On. Final Rept & Corrective Action to Be Provided by 820205 + (ML20033C918)
- 05000277/LER-1981-042-03, /03L-0:on 811021,gland Seal Condenser Bottom Head Gasket Developed Leak & HPCI Sys Declared Inoperable.Caused by Displacement of Gasket on Sealing Surface Between Condenser Shell & Bonnet + (ML20033C921)
- ML20033C922 + (ML20033C922)
- ML20033C923 + (ML20033C923)
- ML20033C924 + (ML20033C924)
- ML20033C925 + (ML20033C925)
- ML20033C928 + (ML20033C928)
- 05000237/LER-1981-064, Forwards LER 81-064/03L-0 + (ML20033C930)
- ML20033C932 + (ML20033C932)
- ML20033C933 + (ML20033C933)
- 05000237/LER-1981-064-03, /03L-0:on 811029,during Pressure Suppression to Vacuum Breaker Dis 1600-3,pressure Switch Trip Point Exceeded Tech Spec.Caused by Setpoint Drift.Valve Readjusted + (ML20033C934)
- ML20033C935 + (ML20033C935)
- ML20033C937 + (ML20033C937)
- ML20033C938 + (ML20033C938)
- ML20033C939 + (ML20033C939)
- ML20033C940 + (ML20033C940)
- ML20033C941 + (ML20033C941)
- ML20033C942 + (ML20033C942)
- ML20033C945 + (ML20033C945)
- ML20033C946 + (ML20033C946)
- ML20033C947 + (ML20033C947)
- 05000286/LER-1981-008, Forwards LER 81-008/01T-0.Detailed Event Analysis Encl + (ML20033C948)
- ML20033C950 + (ML20033C950)
- ML20033C951 + (ML20033C951)
- ML20033C952 + (ML20033C952)
- 05000286/LER-1981-008-01, /01T-0:on 811109,at Hot Shutdown,Two Manual Isolation Vlaves in Weld Channel & Containment Penetration Pressurizaiton Sys Were Closed.Caused by Administrative Error.Valves Opened + (ML20033C953)
- 05000263/LER-1981-024, Forwards LER 81-024/01T-0 + (ML20033C954)
- ML20033C956 + (ML20033C956)
- ML20033C957 + (ML20033C957)
- ML20033C958 + (ML20033C958)
- 05000263/LER-1981-024-01, /01T-0:on 811112,during Maint Shutdown & PM on Hpci,Discovered Abnormal Wear in Woodwear Governor Bracket. Caused by Failed Components Due to Thrust Washer Failure Causing Bushings to Seize to Shaft & Distort Casing + (ML20033C961)
- ML20033C962 + (ML20033C962)
- ML20033C964 + (ML20033C964)