Provides Corrections to Util Re Preliminary Human Factors Review of Facility Control Room.Item 2.9 Should Be Changed to Item 2.8
ML20033C893
Person / Time
Site: Clinton Constellation icon.png
Issue date: 11/25/1981
From: Wuller G
ILLINOIS POWER CO.
To: John Miller
Office of Nuclear Reactor Regulation
References
U-0334, U-334, NUDOCS 8112040471
Download: ML20033C893 (1)


Text

(3 ILLINOIS POWER COMPANY ffy z33_75y_g CLINTON POVvER STATION. R.R. 8:3. BOX 228. CLINTON, IL 61727 November 25, 1981 Mr. James R. Miller Chief, Standarization & Special Projects Branch Division of Licensing Office of Nuclear Reactor Regulation p

m 1

' 'O s A'Q [l; j U.

S. Nuclear Regulatory Commission f'

Washington, D. C.

20555 g4.

h -}g Ofgg

Dear Mr. Miller:

19gIA ~f is,N!'% j Clinton Power Station Unit 1

~ " '

Docket No. 50-461

.g j

EarlieryoureceivedmyletterdatedNovember1(Q1,9,81conceEning the Preliminary Human Factors Review of the Clinton Contrdl$ M om.

Based on a telephone conversation between Illincis Power Company and NRC representatives, we wish to make the following changes in the attachment to that letter.

1)

Item 2.9 should be item 2.8; there is no item 2.9.

2)

Under item 3.53 the correction should read:

"The recommendation should read:

All front row control room lamps shall be periodically tested or procedures should be modified to require the operator, once per shift, to review the lamps to replace burned out lamps.

This review will not require documentation."

3)

Under item 5.15 the correction section should read

" Permanent labels will be installed prior to licensing."

Sincerely, Fo&.

<G.E.Wuller Supervisor - Licensing Nuclear Station Engineering JGC/ajh vool v

Ms. Ann Ramey - Smith, USNRC Ma'.1 Stop 228 cc:

3 Mr. J. H. Williams, NRC Clinton Project Manager ffo Mr. H. H. Livermore, NRC Resident Inspector 811204o471 811125 DR ADOCK 05000461 PDR