Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000311/LER-1981-028-03, /03L-0:on 810603,feeder Breaker 2B4D Tripped When Fan Coil Unit 24 Was Started.Caused by Design Error. Overcurrent Protection Relay Accommodated Only One Fan Cooling Unit.Relay Reset + (ML20005B068)
- ML20005B070 + (ML20005B070)
- ML20005B072 + (ML20005B072)
- 05000272/LER-1981-055, Forwards LER 81-055/03L-0.Detailed Event Analysis Encl + (ML20005B074)
- ML20005B075 + (ML20005B075)
- ML20005B076 + (ML20005B076)
- 05000272/LER-1981-055-03, /03L-0:on 810521,power Lost at Station Power Transformers 12 & 22.Caused by Design Deficiency in Unit 3 Generator Breaker.Power Restored + (ML20005B078)
- ML20005B079 + (ML20005B079)
- ML20005B082 + (ML20005B082)
- IR 015000027/1980066 + (ML20005B083)
- ML20005B084 + (ML20005B084)
- ML20005B086 + (ML20005B086)
- ML20005B087 + (ML20005B087)
- ML20005B088 + (ML20005B088)
- 05000338/LER-1981-048, Forwards LER 81-048/03L-0 + (ML20005B089)
- ML20005B090 + (ML20005B090)
- IR 05000358/1981006 + (ML20005B091)
- IR 05000412/1981002 + (ML20005B093)
- 05000338/LER-1981-048-03, /03L-0:on 810603,visual Insp Revealed Snubber Reservoir Was Damaged & Empty of Fluid.Caused by Heat Damage to Oil Reservoir.Snubber Replaced & Modified by Moving Fluid Reservoir to Remote Location + (ML20005B094)
- ML20005B095 + (ML20005B095)
- 05000277/LER-1981-034, Forwards LER 81-034/01T-0.Detailed Event Analysis Also Submitted + (ML20005B096)
- ML20005B097 + (ML20005B097)
- ML20005B098 + (ML20005B098)
- ML20005B100 + (ML20005B100)
- ML20005B101 + (ML20005B101)
- 05000277/LER-1981-034-01, /01T-0:on 810612,four Cables Found to Be Designated Nonsafeguard & Routed Such That Partial Separation Provided.Caused by Incorrect Plant Design.Design Change Made + (ML20005B103)
- ML20005B104 + (ML20005B104)
- ML20005B105 + (ML20005B105)
- IR 05000546/1981008 + (ML20005B106)
- ML20005B107 + (ML20005B107)
- 05000272/LER-1981-056, Forwards LER 81-056/03L-0.Detailed Event Analysis Encl + (ML20005B108)
- ML20005B109 + (ML20005B109)
- ML20005B110 + (ML20005B110)
- ML20005B112 + (ML20005B112)
- 05000272/LER-1981-056-03, /03L-0:on 810521,power Partially Lost to Containment Sump Level Monitoring Sys.Caused by Design Deficiency in Unit Generator Breaker 3.Power Restored + (ML20005B113)
- ML20005B114 + (ML20005B114)
- ML20005B115 + (ML20005B115)
- 05000311/LER-1981-022, Forwards LER 81-022/03L-0.Detailed Event Analysis Encl + (ML20005B116)
- ML20005B117 + (ML20005B117)
- 05000311/LER-1981-022-03, /03L-0:on 810520,rod 2D4 Dropped.Caused by Corroded Connector Pins.Pins Replaced & Rod Tested Satisfactorily + (ML20005B118)
- AECM-81-222, First Interim Deficiency Rept,Initially Reported 810527 Re Nonconforming Valve Closure Times.Neither Cause Nor Corrective Actions Determined.Vendor Asked to Investigate. Final Rept to Be Submitted by Unit 1 Fuel Load + (ML20005B119)
- ML20005B120 + (ML20005B120)
- IR 05000483/1981011 + (ML20005B122)
- ML20005B123 + (ML20005B123)
- ML20005B124 + (ML20005B124)
- 05000296/LER-1981-030, Forwards LER 81-030/01T-0 + (ML20005B125)
- ML20005B126 + (ML20005B126)
- 05000296/LER-1981-030-01, /01T-0:on 810616,turbine First Stage Permissive Switches PS-1-81A & B & PS-1-91A & B Were Found Above Tech Spec Limit.Caused by Barksdale Model B2T-A12SS Setpoint Drift.Switches Reset + (ML20005B127)
- ML20005B128 + (ML20005B128)
- IR 05000346/1981004 + (ML20005B129)
- ML20005B131 + (ML20005B131)