U.S. NUCLEAR REGULATORY COMilSSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No. 50-277/80-36 50-278/80-29 (15000027/80-66)
'
Docket No. 50-277 50-23 License No. OPR-44/DPR-56 Priori ty Category Licensee:
Philadelphia Electric Company 2301 Market Street Philadelphia, Pennsylvania 19101 Facility Name:
Peach Bottom Nuclear Power Plant Units 2 and 3 Inspection at: Beatty, Nevada Burial Site Inspection conducted:
November 5, 1980
,
Inspectors: See attached report cover sheet date signed
,
Approved by: See attached report cover sheet
.
date signed Inspection Summary:
See attached report cover sheet.
8107C60293 81060~
PDR # DOCK 050002 7 G
P, R
.-
-
.
. - -. -.
-
-
-.
-
--..
_.
-
- -. - -. - -
.
.
w
,
-
'
I.'. 3. ::tCI.~iR PIGULiTCRY CC ' MISSION CFFICC C7 II:S?ICT!:::.i :D I::FCRCE!E!"I'
2 I G I C:i V
.
Raporc-Mo. _80-66 l
Deckat No.
15000027 License No.
safeguards croup
_
Licensee:
,
,
Facility Na=e: Nuclear Engineering Company
-
Inspeccion at: Beattv, Nevada Inspection condue:ec:
November 5. 1980
.W bd'
$
" II Inspsetors:
-
F. R. Lurakowski, Radiation bpecialist
- ace signee l
-
ca:e signeo
- Approved By: R. D. "homas, Chjpf, Mtls. Radiological Prot. Sect 02:e signed Approved 7.y:
- I
-
6T'
kb
)
H. E. Book, Chief, Fuer Facility & Mtls. Safety Br.
v'
ca:e signed S u==a ry :
.
Inspection on November 5, 1980 (Report No. 15000027/80-66)
As part of the inspection conducted on November 5, 1980, the inspection of part of trailer 44578 is detailed in this report.
Because the shipment arrived the week prior to the inspector being on site and the final disposition of the shipment was made the week after the inspector left the site, the inspector
'
can only detail what he saw personally, mainly the two drums with the loose lids. Otner information in this report was obtained from the State of Nevada Inspector's report.
.
A representative from the Department of Transportation was not present during this inspection.
Burt Grey from the Nevada State Health Division was present during this inspection.
.
Results:
One apparent item of noncompliance with D0T/NRC regulations was observed. See paragraph 2.
It appears that the NRC Region I Office, the State of Nevada and the Department of Transp tation are the appropriate organizations to take enforcement actions.
RV Form 219 (2)
~
....
,
l
%--
..
..
- -, - - - - -
- -,., -, - - -.....
_
, _,,
.
s,.
.
.
,
'
.
Persons Contacted Steve Carpenter,' Site Manager, NEC0 Mark Poirier, Assistant Site Manager and Chenical Safety Officer, NEC0 Jim Cruickshank, Radiation Safety Officer, NECO Burt Grey, Nevada State Health Division Background As part of the low level waste inspection conducted during November 4-7, 1980 at Beatty, Nevada, a portion of the shipping papers and trailer number 444578 were inspected on November 5, 1980.
Because the truck arrived the week prior to the inspector being on site and the final disposition of the shipment was made the week after the inspector left the site, no surveys were made.
Surveys were made by the State of Nevada inspector.
Some information in this report was obtained from the State Inspector's report.
Inspection
'
Licensee - Shipper:
Philadelphia Electric Company 2301 Market Street Philadelphia, Pennsylvania 19101
.
Shipment Inspected (partial):
November 5, 1980 Docket Nos. 5000277/5000283 Carrier:
'iri-State Motor Transit Company
.
Trailer No:
444578 Shipment No.:
PB-270-80 1.
This shipment consisted of 66 drums of LSA radioactive material, no other packages were on this truck other than those shipped to the disposal site.
2.
(a) During the partial inspection of trailer number 444578 it was noted that drum number 107 had the lid raised approximately
3/4-inch and tne lock ring was not secure.
The bolt which was
'
to secure the lock ring and lid appeared to have been backed off, leaving the lid and lock ring loose.
i
,
l
'
l l
f
..
.
-
.:
.
.
.
,
-
'
.
,
-2-(b) The lock ring of drum number 69 was loose.
The above situations appear to be in noncompliance with 49 CFR 173.392 (c)(1) which requires that materials must be packaged in strong, tight packages so that there will be no leakage of radioactive material under conditions normally incident to transportation.
3.
All radiation surveys of the vehicle, and checks for removable contamination were conducted by the State of Nevada inspector. All results were acceptable.
.
.
De