- ML20004E704 + (ML20004E704)
- ML20004E705 + (ML20004E705)
- ML20004E706 + (ML20004E706)
- A01184, Submits Resolution of Cycle 4 Startup Commitments,Re Effect of Predicted Bundle Deformation on Heat Transfer from Fuel Rods During Reflooding Stage of LOCA + (ML20004E708)
- ML20004E709 + (ML20004E709)
- ML20004E710 + (ML20004E710)
- IR 05000461/1981007 + (ML20004E711)
- ML20004E712 + (ML20004E712)
- ML20004E713 + (ML20004E713)
- ML20004E714 + (ML20004E714)
- 05000272/LER-1981-054, Forwards LER 81-054/01T-0.Detailed Event Analysis Encl + (ML20004E715)
- ML20004E716 + (ML20004E716)
- ML20004E717 + (ML20004E717)
- 05000272/LER-1981-054-01, /01T-0:on 810521,vendor Advised That Regulatory Requirements Could Be Violated by Failure of Vol Control Tank Level Control Sys & Subsequent Loss of Suction to Centrifugal Charging Pump W/Failure of Remaining Pump + (ML20004E718)
- ML20004E719 + (ML20004E719)
- ML20004E721 + (ML20004E721)
- ML20004E722 + (ML20004E722)
- ML20004E724 + (ML20004E724)
- ML20004E725 + (ML20004E725)
- ML20004E726 + (ML20004E726)
- ML20004E727 + (ML20004E727)
- ML20004E729 + (ML20004E729)
- ML20004E730 + (ML20004E730)
- ML20004E732 + (ML20004E732)
- ML20004E733 + (ML20004E733)
- 05000331/LER-1981-019-01, /01T-0:on 810526,found Tech Spec Surveillance Requirements for Determining River Water Supply Sys Pump TDH Not Being Met.Caused by Limits on Nameplate Data Being Too Stringent for Normal Operation + (ML20004E734)
- IR 05000271/1980019 + (ML20004E735)
- 05000311/LER-1981-023, Forwards LER 81-023/01T-0.Detailed Event Analysis Encl + (ML20004E736)
- ML20004E737 + (ML20004E737)
- ML20004E738 + (ML20004E738)
- 05000311/LER-1981-023-01, /01T-0:on 810522,main Steam Isolation Valves Failed to Close within Required 5-s During Startup Test. Caused by Design Error.Design Change Developed to Allow for Proper Interaction of Hydraulic & Steam Closing Subsys + (ML20004E739)
- 05000261/LER-1981-013, Forwards Updated LER 81-013/03L-1 + (ML20004E740)
- ML20004E741 + (ML20004E741)
- ML20004E742 + (ML20004E742)
- 05000261/LER-1981-013-03, Determined Containment Isolation Valves Not Tested in Required Manner.Seven of Eight Valves Functioning as Designed.Eighth Valve Tested & Shown Operable.Test Undergoing Revision + (ML20004E744)
- ML20004E745 + (ML20004E745)
- 05000272/LER-1981-047, Forwards LER 81-047/03L-0.Detailed Event Analysis Encl + (ML20004E746)
- ML20004E747 + (ML20004E747)
- ML20004E748 + (ML20004E748)
- 05000272/LER-1981-047-03, /03L-0:on 810513,containment Air Lock Leak Rate Exceeded Design Pressure Tech Spec Limit During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested + (ML20004E749)
- ML20004E750 + (ML20004E750)
- 05000338/LER-1981-028, Forwards LER 81-028/03L-0 + (ML20004E751)
- ML20004E752 + (ML20004E752)
- IR 05000219/1981001 + (ML20004E753)
- 05000338/LER-1981-028-03, /03L-0:on 810511,component Cooling Pipe Support & Snubber Removed Per Design Change 80-S46.Caused by Snubber Listed in Both Units 1 & 2 Tech Specs Although Installed on Unit 2 Piping of Common Sys.Snubber Deleted from Tech S + (ML20004E754)
- 05000245/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20004E755)
- 05000245/LER-1981-009-03, /03L-0:on 810511,during Main Steam Line High Radiation Functional Test,Subchannel B Found to Trip Outside Acceptable Trip Setpoint Band.Caused by Instrument Setpoint Drift.Subchannel Recalibr & Tested + (ML20004E757)
- ML20004E758 + (ML20004E758)
- ML20004E759 + (ML20004E759)
- ML20004E760 + (ML20004E760)
- ML20004E761 + (ML20004E761)