ML20004E747

From kanterella
Jump to navigation Jump to search
Forwards LER 81-047/03L-0.Detailed Event Analysis Encl
Date released: 01/18/2020 Download: ML20004E747


LER 81-047/03L-0:on 810513,containment Air Lock Leak Rate Exceeded Design Pressure Tech Spec Limit During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested
ML20004E749
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/08/1981
From: Espey J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004E749 (1)
Forwards LER 81-047/03L-0.Detailed Event Analysis Encl
ML20004E746
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/08/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004E746 (2)