- ML20002B003 + (ML20002B003)
- 05000301/LER-1980-009, Forwards LER 80-009/03L-0 + (ML20002B005)
- ML20002B006 + (ML20002B006)
- ML20002B007 + (ML20002B007)
- ML20002B008 + (ML20002B008)
- ML20002B009 + (ML20002B009)
- ML20002B010 + (ML20002B010)
- ML20002B011 + (ML20002B011)
- 05000301/LER-1980-009-03, /03L-0:on 801101,during Normal Operation, Performance of ICP 2.14 Found P8 Permissive Bistable from Channel N44 to Be Set at 50.5%.Caused by Instrument Drift. Bistable Adjusted & Tested Satisfactorily + (ML20002B012)
- 05000338/LER-1980-098, Forwards LER 80-098/03L-0 + (ML20002B013)
- ML20002B014 + (ML20002B014)
- 05000338/LER-1980-098-03, /03L-0:on 801123,while Operating in Mode 1,neutron Flux Distribution Exceeded Axial Flux Difference Target Band.Caused by Xenon Transient.Control Rods Inserted,Causing Flux Distribution to Shift Downward + (ML20002B015)
- ML20002B016 + (ML20002B016)
- ML20002B017 + (ML20002B017)
- ML20002B018 + (ML20002B018)
- ML20002B019 + (ML20002B019)
- ML20002B020 + (ML20002B020)
- ML20002B021 + (ML20002B021)
- 05000324/LER-1980-092, Forwards LER 80-092/03L-0 + (ML20002B022)
- ML20002B023 + (ML20002B023)
- 05000324/LER-1980-092-03, /03L-0:on 801106,08,12,15,18,22 & 23,containment Atmospheric Monitor 2-CAC-AT-1259,Beckman Model F3,tripped Due to Loss of Sample Flow.Caused by Water Accumulation in Torus Sample Line to Monitor.Water Removed + (ML20002B024)
- 05000213/LER-1980-016, Forwards LER 80-016/03L-0 + (ML20002B025)
- ML20002B027 + (ML20002B027)
- 05000213/LER-1980-016-03, /03L-0:on 801118,audible & Visual Alarms Indicated Two Dropped Rods & Initiation of Turbine Load Runback.Caused by Badly Burnt Arc Chute & Auxiliary Contacts on One Side of Type MM310 Contactor Rubbing & Impeding Operation + (ML20002B028)
- 05000409/LER-1980-016, Forwards LER 80-016/01T-0 + (ML20002B029)
- 05000409/LER-1980-016-01, /01T-0:on 801202,hourly Fire Watch Patrol Not Established within 1-h of Drilling Holes Through Turbine Bldg Barriers for Fire Protection & Sampling Sys.Job Coordinators Reminded of Fire Barrier Requirements + (ML20002B031)
- ML20002B032 + (ML20002B032)
- ML20002B034 + (ML20002B034)
- 05000282/LER-1980-036, Forwards LER 80-036/03L-0 + (ML20002B035)
- ML20002B036 + (ML20002B036)
- ML20002B038 + (ML20002B038)
- 05000321/LER-1980-117, Forwards LER 80-117/03L-0 + (ML20002B039)
- ML20002B040 + (ML20002B040)
- 05000346/LER-1980-080, Forwards LER 80-080/03L-0 + (ML20002B041)
- ML20002B042 + (ML20002B042)
- 05000282/LER-1980-036-03, /03L:on 801105,battery Charger 12 Failed to Provide Normal Output.Caused by Firing Card B Not Providing Pulses to Fire B Phase Scr.Card Replaced + (ML20002B043)
- 05000320/LER-1980-049, Forwards LER 80-049/01L-0 + (ML20002B044)
- 05000321/LER-1980-117-03, /03L-0:on 801104,no Transfer Authorizations Discovered for Receipt of Two Shipments of Low Power Range Monitors & One Shipment of Source Range & Radiation Monitors.Caused by Misinterpretation of Procedures + (ML20002B046)