NOV 171980 MEMORANDUM FOR:

R. O. Meyer, Leader, Reactor Fuels Section, CPB, DSI FROM D. A. Powers, Reactor Fuels Section, CBP, DSI

SUBJECT:

GUIDE TUBE WEAR INPUT FOR THE ANNUAL REPORT As requested for the next Fuel Performance Annual Report, I have prepared the attached material which discusses the licensing actions during 1979 that pertain to PWR guide tube wear.

b.

M

-D. A. Powers i

Reactor Fuels Section Core Performance Branch O

Division of Systems Integration

.a ~

Attachment:

1:". i

+

As stated b

. !;j

'~

s 2

o S

cc:

L. Rubenstein M. Tokar W. Johnston I

e

.g.

-80'l2090 2C 7

i ATTACHMENT As reported in last year's annual report (1), a fretting wear has been observed i

in irradiated fuel assemblies taken from operating PWR reactors.

These observa-tions' revealed an unexpected degradation of redded guide tubes.

It was subse-quently concluded that coolant turbulence was responsible for inducing vibratory motions in the normally fully withdrawn control rods and, when these vibrating rods were in contact with the inner surface of the guide tubes, a wearing of the guide tube wall has taken place.

Significant wear has been found to be limited to the relatively soft Zircaloy-4 guide tubes because the Inconel-625 cladding on the control rods provides a relatively hard wear surface. The j

extent of the observed wear has been observed to be both time and plant dependent and has in some cases extended completely through the tube wall.

4 Guide tubes function principally as the main structural members of the fuel assembly and as channels to guide and decelerate control rod motion.

Signifi-cant loss of mechanical integrity due to wear or hole formation could (a) result in the inability of the guide. tubes to withstand their, anticipated loadings for fuel handling accidents and condition 1-4 events and (b) hinder

.scramability.

Therefore in light of this significance, the NRC staff has continued to review the guide ~ tube wear issue on both a generic basis with vendors and owner's groups and on a case-by-case basis with applicants and licensees.

f i

.l

-g.

i i

f j

Combustion Engineering i

i During 1979 C-E continued ta rely mainly on chrome plated stainless-steel l

sleeves to mitigate control rod wear to guide tube walls.

In pursuit of a permanent solution, C-E now has/ flow modifying test assemblies inpile at four i

plants: Maine Yankee; Arkansas Nuclear One, Unit 2; Millstone, Unit 2; and Calvert Cliffs, Unit 2.

In 1979 reload outage surveillance on guide tube integrity was reported on five C-E NSSS plants:

Fort Calhoun (2); Millstone, Unit 2 (3); St. Lucie, Unit 1 (4); Calvert Cliffs, Unit 1 (5); and Calvert Cliffs, Unit 2 (G). The i

surveillance (5) at Calvert Cliffs, Unit 1 reveP ed a large number of sleeved guide tubes that failed confirmatory pull testing (non-destructive testing which is used to verify adequate motion resistance of the sleeve to axial drag

' force).

The affected guide tubes were found to be unique to the specific installation sequence procedure used only on previously irradiated fuel assem-blies at Calvert Cliffs, Unit 1.

Repairs were subsequently performed by recrimping the affected guide tube sleeves. With the exceptio'n of this anomaly, the C-E use of sleeves continues to be an acceptable means of alleviating guide tube wear.

Westinghouse In response to the NRC's attempt to assess the susceptibility and impact of guide t[ube wear.in Westinghouse plants, Westinghouse submitted informacion (7) on (a) guide tube wear measurements taken on irradiated 14x14 fuel assemblies e

.r.,

y-,,

. from Point Beach, Units 1 and 2, (b) a mechanistic wear model, and (c) the impact of the model's wear predictions on the safety analyses of plant designs.

Westinghouse believes that their fuel designs will experience less wear than that reported in some other NSSS designs because the Westinghouse designs use thinner, more flexible, control rods that have relatively more lateral support in the gui6a tube assembly of the upper core structure.

The staff concluded (for example see Reference 8) that the Westinghouse analysis probably accounts for all of the major variables that control this wear process, and that the wear in 15x15 fuel assemblies should be equivalent to that experi-enced and measured in 14x14 fuel assemblies, and therefore these designs are not likely to experience significant wear to the degree that the design capa-bilities will be impaired.

However, because of the complexities and uncertainties in determining input variables for the new 17x17 fuel assembly design, the staff required (for example see Reference 8) several near-term OL applicants to submit to a sur-veillance program. For acceptability, the minimum objective of such program was to demonstrate that there is no occurrence of hole formation in rodded i

guide tubes. At present these applicants are forming an owner's group which is tentatively planning to submit a surveillance program during 1980.

~

w=

.g.

Babcock & Wilcox Responding to NRC inquiries, B&W has submitted information (9) on their assess-ment of the potential for guide tube wear in their plants.

The C&W submittal did not provide a means for predicting the rate of wear nor were wear measure-ments on irradiated fuel assemblies submitted, therefore the submittal was found to be deficient (10).

Consequently, NRC has required (for example see Reference 11) that B&W licensees and an applicant provide confirmatory measure-ments on spent fuel assemblics that verifies that the B&W designs will not experience through-the-wall wear in guide tubes.

On December 20, 1979, a B&W owner's group met with the NRC staff and presented the details of a preliminary 1980 surveillance program designed to verify the resistance of B&W NSSS plants to guide tube wear.

Exxon ENC will supply (12) the reload fuel for cycle 5 operation of " Maine Yankee.

To mitigate guide tube wear in this C-E designed plant, the ENC fuel will incorporate a sleeved guide tube design that is similar to that used in the residual fuel assemblies which were supplied by C-E.

In light of the lower wear rates in W designed plants, the ENC reload fuel for these NSSS plants do not employ design modifications to reduce guide tube i

wear.

In 1980 ENC plans (13) to perform surveillance on their spent fuel assemblies discharged from H. B. Robinson, Unit 2 to verify the adequacy of their guide tube design in W plants.

l

\\

e y-r--

. REFERENCES 1.

M. Dean Houston, " Fuel Performance Annual Report (Period Through December 1978)," USNRC Report NUREG-0633, December 1979.

2.

Letter from T. E. Short, Omaha Public Power District, to Director of I&E, USNRC, Docket No. 50-285, dated March 1,1979.

3.

Letter from W. G. Council, Northeast Utilities, to R. Reid, USNRC, Docket No. 50-336,

Subject:

" Sleeved CEA Guide Tube Inspection," dated May 23, 1979.

4.

Letter from R. E. Uhrig, Florida Power and Light Company, to R. W. Reid, USNRC, Docket No. E0-335,

Subject:

"CEA Guide Tube Inspection / Evaluation,"

dated May 23, 1979.

5.

Letter from W. J. Lippold, Baltimore Gas and Electric Company, to E. Conner, USNRC, Docket No. 50-317, dated May 24, 1979.

6.

Letter from R. C. L. Olson, Baltimore Gas and Electric Company, to R. W. Reid, USNRC, Docket No. 50-318,

Subject:

CEA Guide Tube Inspection Program," dated November 12, 1979.

7.

Letter from T. M. Anderson, Westinghouse Electric Corporation, to D. G. Eisenhut, USNRC, NS-TMA-2102, dated June 27, 1979.

8.

Letter from L. S. Rubenstein, USNRC, to H. G. Parris, Tennessee Valley Authority, Docket Nos. 50-327/328,

Subject:

" Degradation of Guide Thimble Tube Walls," dated Decemser 14, 1979.

9.

Letter from J. H. Taylor, Babcock & Wilcox, to B. K. Grimes, USNRC, dated January 12, 1979.

10.

Letter from B. K. Grimes, USNRC, to J. H. Taylor, Babcock & Wilcox, dated August 22, 1979.

11.

Letter from L. S. Rubenstein, USNP.C, to S. H. Howell, Consumers Power Company, Docket Nos. 50-329/330,

Subject:

" Request for Additional Information on Fuel Assembly Guide Tube Wear for Midland Plant, Units 1 and 2," dated November 15, 1979.

12.

Letter from R. H. Groce, Maine Yankee Atomic Power Company, to R. W. Reid, USNRC, Docket No. 50-309,

Subject:

" Questions Pertaining to Cycle 5 Reload Fuel," dated November 6,1979.

13.

Letter from G. F. Owsley, Exxon Nuclear Company, to T. A. Ippolito, USNRC, dated December 5, 1979.

e

- e

.gi, e=w

-e%

mg e, e ee es b

ei