Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- A01517, Forwards Full Payment of Class II Amend Fee.Nrc 810223 Memo Advising of Applicability of Class II Fee Encl + (ML19351G551)
- 05000325/LER-1981-013, Forwards LER 81-013/03L-0 + (ML19351G552)
- ML19351G553 + (ML19351G553)
- 05000325/LER-1981-013-03, /03L-0:on 810122,rod Worth Minimizer Sys Rod Blocks Were Received W/Proper Adherence to Control Rod Pattern Pull Sheet.Caused by Inadequate Procedures.Rods Pulled to Correct Position + (ML19351G554)
- 05000325/LER-1981-012, Forwards LER 81-012/03L-0 + (ML19351G555)
- ML19351G556 + (ML19351G556)
- 05000325/LER-1981-012-03, /03L-0:on 810122,rod 26-35 Did Not Have Position Indication at Position 03 & Rod 34-35 Did Not Have Position Indication at Position 02.Caused by Defective Rod Position Indication Reed Switches.Corrective Maint Will Be Comple + (ML19351G557)
- ML19351G558 + (ML19351G558)
- ML19351G559 + (ML19351G559)
- ML19351G560 + (ML19351G560)
- ML19351G561 + (ML19351G561)
- ML19351G562 + (ML19351G562)
- 05000324/LER-1981-011, Forewards LER 81-011/03L-0 + (ML19351G563)
- ML19351G564 + (ML19351G564)
- 05000324/LER-1981-011-03, /03L-0:on 810120 & 0123,actual Pool Level Determined in Excess of Upper Tech Spec Limit.Caused by Improper Calibr Data & Calibr Procedure Inadequacy.Procedure Revision Underway & Indicators Correctly Calibr + (ML19351G565)
- 05000325/LER-1981-010, Forwards LER 81-010/03L-0 + (ML19351G566)
- ML19351G567 + (ML19351G567)
- 05000325/LER-1981-010-03, /03L-0:on 810120,upon Auto Initiation After Reactor Scram,Rcic Turbine Failed to Accelerate to Idle Speed,Making RCIC Inoperable.Caused by Dirty Contacts in Turbine Steam Inlet Supply Valve 1-E51-F045.Contacts Cleaned + (ML19351G568)
- ML19351G569 + (ML19351G569)
- 05000325/LER-1981-011, Forwards LER 81-011/03L-0 + (ML19351G570)
- ML19351G571 + (ML19351G571)
- 05000325/LER-1981-011-03, /03L-0:on 810121,during Routine Shutdown Operation,Seat Leakage Discovered on Reactor Recirculation Sample Inboard Isolation Valve 1-B32-F019.Cause Unknown. Valve Will Be Inspected & Repaired During Next Outage + (ML19351G572)
- ML19351G573 + (ML19351G573)
- ML19351G575 + (ML19351G575)
- ML19351G576 + (ML19351G576)
- ML19351G577 + (ML19351G577)
- ML19352A000 + (ML19352A000)
- ML19352A001 + (ML19352A001)
- AECM-80-312, Final Deficiency Rept Re Damaged Insulation on Stator Coils of B Diesel Generator Set,Initially Reported 800723.Cause Unknown.Stator Coils Returned to Transamerica Delaval,Inc for Repair + (ML19352A002)
- ML19352A003 + (ML19352A003)
- ML19352A004 + (ML19352A004)
- ML19352A007 + (ML19352A007)
- ML19352A010 + (ML19352A010)
- ML19352A011 + (ML19352A011)
- ML19352A012 + (ML19352A012)
- ML19352A013 + (ML19352A013)
- IR 05000289/1980002 + (ML19352A014)
- ML19352A015 + (ML19352A015)
- ML19352A017 + (ML19352A017)
- ML19352A018 + (ML19352A018)
- ML19352A019 + (ML19352A019)
- ML19352A020 + (ML19352A020)
- IR 05000317/1980021 + (ML19352A021)
- ML19352A022 + (ML19352A022)
- ML19352A025 + (ML19352A025)
- 05000312/LER-1981-005, Forwards LER 81-005/04L-0 + (ML19352A026)
- 05000312/LER-1981-005-04, /04L-0:on 810125,plant Liquid Effluent Ph Exceeded 8.5 Limit Established by Tech Spec App B,Section 2.4.Caused by Slightly out-of-tolerance Setpoint.Diversion Setpoint Was Reset.Alarm Setpoint Will Be Lowered + (ML19352A028)
- ML19352A029 + (ML19352A029)
- ML19352A030 + (ML19352A030)
- PNO-II-81-016, on 810216,loss of Control Room Panel Annunciation Occurred.Caused by 120-volt External Power Source.Normal Annunciator Function Restored + (ML19352A031)
- ML19352A032 + (ML19352A032)