- ML19351F913 + (ML19351F913)
- 05000302/LER-1981-004-03, /03L-0:on 810119,position Indication for Containment Isolation Valves CAV-2 & CAV-126 Found Inoperable,In Violation of Tech Spec 3.6.3.1.Cause of CAV-2 Inoperability Unknown.Cause of CAV-126 Was Bad Breaker + (ML19351F914)
- 05000369/LER-1981-002, Forwards LER 81-002/01T-0 + (ML19351F915)
- ML19351F916 + (ML19351F916)
- ML19351F917 + (ML19351F917)
- ML19351F918 + (ML19351F918)
- 05000369/LER-1981-002-01, /01T-0:on 810130,during Test,Vent Valve VX-41 & Containment Isolation Valve XV-40 Found Open to Atmosphere, in Violation of Tech Spec 4.9.4.1.Caused by Lack of Valve Checklist & Lack of Periodic Test.Valves Closed + (ML19351F919)
- 05000302/LER-1981-005, Forwards LER 81-005/03L-0 + (ML19351F920)
- ML19351F921 + (ML19351F921)
- ML19351F922 + (ML19351F922)
- ML19351F923 + (ML19351F923)
- 05000302/LER-1981-005-03, /03L-0:on 801215,mechanical Seal for Bldg Spray Pump BSP-1A Found Leaking Greater than 6 Gallons/H,In Violation of Tech Spec 3.6.2.1.Caused by Defective Mechanical Seal.Review of Maint Procedure in Progress + (ML19351F924)
- ML19351F925 + (ML19351F925)
- ML19351F927 + (ML19351F927)
- ML19351F928 + (ML19351F928)
- ML19351F929 + (ML19351F929)
- ML19351F932 + (ML19351F932)
- 05000334/LER-1981-008, Forwards LER 81-008/03L-0 + (ML19351F936)
- ML19351F937 + (ML19351F937)
- ML19351F938 + (ML19351F938)
- 05000334/LER-1981-008-03, /03L-0:on 810112,low Pressure Alarm Received on Safety Injection Accumulator SI-TK-1C.Caused by Leaking Drain Valve.Pressure Restored Above Tech Spec Limit & Valves Will Be Repaired or Replaced During Next Outage + (ML19351F939)
- 05000318/LER-1981-008, Forwards LER 81-008/03L-0 + (ML19351F940)
- ML19351F941 + (ML19351F941)
- 05000318/LER-1981-008-03, /03L-0:on 810113,steam Generator 22 Low Pressure Bistable Meter 2D Found Out of Calibr & Signal Isolator 2-E/E-1023A Failed.Caused by Natural Wear & Aging.Cause of Isolator Failure Not Stated + (ML19351F942)
- ML19351F943 + (ML19351F943)
- ML19351F944 + (ML19351F944)
- 05000317/LER-1981-008, Forwards LER 81-008/01T-0 + (ML19351F945)
- ML19351F946 + (ML19351F946)
- ML19351F947 + (ML19351F947)
- 05000317/LER-1981-008-01, /01T-0:on 810203,discovered That When Fire Hose Stations in Auxiliary Bldg & Unit 2 Containment Bldg Were Isolated,Backup Fire Hose Not Routed as Required.Caused by Personnel Error.Backup Hoses Routed as Required + (ML19351F948)
- ML19351F949 + (ML19351F949)
- ML19351F950 + (ML19351F950)
- ML19351F951 + (ML19351F951)
- ML19351F952 + (ML19351F952)
- 05000155/LER-1980-044, Forwards Updated LER 80-044/03X-1 + (ML19351F953)
- ML19351F955 + (ML19351F955)
- ML19351F957 + (ML19351F957)
- ML19351F960 + (ML19351F960)
- ML19351F962 + (ML19351F962)
- IR 05000259/1980035 + (ML19351F965)
- ML19351F966 + (ML19351F966)
- 05000409/LER-1981-001-03, /03L-0:on 810116,independent Circuit Between Offsite Transmission Network & Onsite Power Distribution Sys Disconnected.Caused by Maint on Main Transformer Airbreak Switch 25NA1 Due to Ice in Swivel Joint.Ice Melted + (ML19351F967)
- ML19351F968 + (ML19351F968)
- IR 05000305/1980024 + (ML19351F969)
- ML19351F970 + (ML19351F970)
- 05000155/LER-1980-044-03, Output Voltage Regulator Failed & Circuit Breakers to Personnel & Equipment Locks & Lighting Transformer Tripped.Caused by Open Connection to Excitation Buildup Relay Coil Due to Aging & Vibration + (ML19351F972)
- ML19351F973 + (ML19351F973)
- ML19351F974 + (ML19351F974)
- ML19351F975 + (ML19351F975)
- ML19351F976 + (ML19351F976)
- ML19351F977 + (ML19351F977)