~ EN N ES S E E '.' LmZ1

.m f M C. ~ ~

400 Chestnut Street Tower II February 12, 1981 SQRD-50-328/81-04 0

b 5[g2) 0 lg,.f"1

- -I ts 0

Mr. James O'Reilly, Director J

Office of I tion and Enforcement gk U.S. Nuclear latory Commis::icn Regim II - Suit 3100 S

D 6

101 Marietta Stree Atlanta, Georgia 30 3

Dear Mr. O'Reilly:

SEQUOTAE NUCLEAR PLANT UNIT 2 - ENVIRONMENTAL QUALIFICATION OF SAFETT-RELATED ELECTRICAL EQUIPMENT - SQRD-50-328/81 SECOND INTERIM REPORT The subject deficiency was initially reported to NRC-CIE Inspector R. W. Wright m December 8,1^f0, in accordance with 10 CFR 50.55(e) as NCR SQN EB 8044R1. Enclosed ts our second interim report. We expect to submit our next report by March 17, 1981.

If you have any questions, please get in touch with D. L. Lambert at FTS 857-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITT L. M. Mills, Manager Nuclear Regulation and Safety Enclosure Mr. Victor Stello, Director (Enclosure), y V

oc:

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 Gott l

5'l 1

81022006SP S

i l

ENCLOSURE SEQUOYAH NUCLEAR PLANT UNIT 2 ENVIRCNMENTAL QUALIFICATION OF ELECTRICAL EQUIPMENT SQRD 50-328/81-04 10 CFR 50.55(e)

SECOND INTERIM REPORT

~

Descriptien of Deficiency Automatic Switch Company (ASCO) solenoid valves (models HB8300C58RU, HBS262CO2, HTX8320A22V, and HT8316C15) are used to control various containment isolation valves in the plant control air, radiacion monitoring, and ventilation systems. The subject valves are located in the annulus regien. Informatien obtained from ASCO indicated that the solenoids in question were not qualified for the following postaccident environment in the annulus:

Temperature:

150 F Pressure:

Atmospheric 4

]-

Relative Humidity:

100 peycent Radiatien:

7 X 10 rads 3

Interim Progress The solenoids in the control air and ventilati'en system ( ASCO models HB8300C58RU, HB8262C22, and HT8315C15) will be replaced with qualified valves. A TVA engineering change notice has been written which requires the replacement of these valves before unit fuel loading.

This work will be accomplished within the specified implementation schedult As for the solenoids in the radiation monitoring s/ stem

( ASCO model HTX8320A22V), TVA is continuing its investigation to determine whether the subject valves should be either repaired, relocated, or replaced.

y e

ir

-rw--ye--------

yyy---*

-t Tv=e-r

--w--

r e-4'w-e-evy+~*w+----7-e--r-m----*v-v-+-tme*T-

-*-we-

'*--*v--t--v rr* - - -r-*m

+- *

-t'r=' - -

-