Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19341C528 + (ML19341C528)
- ML19341C529 + (ML19341C529)
- ML19341C530 + (ML19341C530)
- ML19341C532 + (ML19341C532)
- ML19341C534 + (ML19341C534)
- ML19341C535 + (ML19341C535)
- ML19341C536 + (ML19341C536)
- ML19341C537 + (ML19341C537)
- ML19341C538 + (ML19341C538)
- ML19341C541 + (ML19341C541)
- ML19341C543 + (ML19341C543)
- ML19341C544 + (ML19341C544)
- ML19341C545 + (ML19341C545)
- ML19341C546 + (ML19341C546)
- ML19341C547 + (ML19341C547)
- ML19341C548 + (ML19341C548)
- ML19341C549 + (ML19341C549)
- 05000312/LER-1981-007, Forwards LER 81-007/01T-0 + (ML19341C550)
- ML19341C552 + (ML19341C552)
- ML19341C553 + (ML19341C553)
- 05000312/LER-1981-007-01, /01T-0:on 810210,info Received That Certain safety-related Instrument Errors Exceed Those Assumed in FSAR Analysis.Possibly Caused by String Error Discrepancies. Applicability of Methodology Used in Rept Being Reviewed + (ML19341C554)
- ML19341C555 + (ML19341C555)
- ML19341C556 + (ML19341C556)
- 05000325/LER-1981-015, Forwards LER 81-015/03L-0 + (ML19341C557)
- ML19341C558 + (ML19341C558)
- ML19341C559 + (ML19341C559)
- ML19341C560 + (ML19341C560)
- ML19341C561 + (ML19341C561)
- 05000325/LER-1981-015-03, /03L-0:on 810127,rod Block Monitor B Failed to Initiate RTGB Downscale Alarm & Rod Out Block at Downscale Alarm Setpoint.Caused by Mechanically Stuck Contacts in Control Relay K-2 in Cabinet Circuitry.Relay Replaced + (ML19341C562)
- 05000321/LER-1981-009, Forwards LER 81-009/03L-0 + (ML19341C563)
- ML19341C564 + (ML19341C564)
- 05000321/LER-1981-009-03, /03L-0:on 810206,nitrogen Storage Tank Inventory Went Below 2000 Gallon Tech Spec Requirement.Caused by Supplier Delaying Shipment.Shipment Received.Supplier Instructed Not to Delay Shipments + (ML19341C565)
- ML19341C566 + (ML19341C566)
- 05000366/LER-1981-011, Forwards LER 81-011/03L-0 + (ML19341C567)
- ML19341C568 + (ML19341C568)
- ML19341C569 + (ML19341C569)
- ML19341C570 + (ML19341C570)
- 05000312/LER-1981-004, Forwards LER 81-004/03L-0 + (ML19341C571)
- ML19341C573 + (ML19341C573)
- ML19341C574 + (ML19341C574)
- 05000366/LER-1981-011-03, /03L-0:on 810204,nonrated Window Discovered in 3-h Rated Fire Wall.Caused by Design,Mfg & Const/Installation Error.Direct Conversion Reactor Study 81-48 Submitted & Fire Watch Established + (ML19341C575)
- 05000312/LER-1981-004-03, /03L-0:on 810202,component Cooling Water Isolation Valve Failed to Close During Surveillance Procedure 205.07C, Isolation Valve Surveillance test,SFV-46204.Caused by Water in Air Line of Valve Actuator.Water Drained + (ML19341C576)
- ML19341C577 + (ML19341C577)
- ML19341C578 + (ML19341C578)
- ML19341C579 + (ML19341C579)
- ML19341C580 + (ML19341C580)
- ML19341C581 + (ML19341C581)
- ML19341C582 + (ML19341C582)
- AECM-80-254, Deficiency Rept Re Failure of Tack Weld on safety-related Automatic Air Damper Supplied by Pacific Air Products Co, Initially Reported on 800912.Util Working W/Constructor Re Reportability Per 10CFR50.55e & 10CFR21 + (ML19341C584)
- ML19341C585 + (ML19341C585)
- ML19341C586 + (ML19341C586)