- ZS-2018-0027, Report on Status of Decommissioning Funding for Shutdown Reactors + (ML18093A434)
- IR 05000272/1987008 + (ML18093A435)
- ML18093A437 + (ML18093A437)
- ML18093A438 + (ML18093A438)
- ML18093A439 + (ML18093A439)
- ML18093A441 + (ML18093A441)
- PMNS20180418, Annual Assessment Meeting + (ML18093A443)
- ML18093A444 + (ML18093A444)
- ML18093A445 + (ML18093A445)
- ML18093A446 + (ML18093A446)
- ML18093A447 + (ML18093A447)
- ML18093A448 + (ML18093A448)
- ML18093A450 + (ML18093A450)
- ML18093A451 + (ML18093A451)
- ML18093A453 + (ML18093A453)
- ML18093A454 + (ML18093A454)
- 05000272/LER-1987-011-02, :on 870917,determined That Breaker Coordination Could Not Be Shown to Be Documented for Several Voltage Levels.Cause Unknown.Investigations Continuing to Identify Historical Breaker Coordination Basis + (ML18093A455)
- ML18093A459 + (ML18093A459)
- ML18093A461 + (ML18093A461)
- IR 05000272/1987025 + (ML18093A462)
- ML18093A465 + (ML18093A465)
- ML18093A470 + (ML18093A470)
- ML18093A471 + (ML18093A471)
- ML18093A472 + (ML18093A472)
- ML18093A473 + (ML18093A473)
- ML18093A474 + (ML18093A474)
- PMNS20180421, Annual Assessment Meeting + (ML18093A476)
- ML18093A477 + (ML18093A477)
- ML18093A478 + (ML18093A478)
- ML18093A479 + (ML18093A479)
- ML18093A480 + (ML18093A480)
- ML18093A481 + (ML18093A481)
- ML18093A483 + (ML18093A483)
- ML18093A484 + (ML18093A484)
- 05000311/LER-1987-012-01, :on 870930,discovered That 6-inch Curb Not Installed at Entrance of Auxiliary Bldg Sump Tank Room,Per Design.Cause Attributed to Personnel Error.Curb Reinstalled & Labeled + (ML18093A485)
- 05000311/LER-1987-013-01, :on 871002,discovered That Prior Month Required Tech Spec Surveillance 4.8.1.1.3.a.2 Not Performed for Diesel Generator Fuel Oil Transfer Pump 22.Caused by Inadequate Procedural Control + (ML18093A486)
- ML18093A487 + (ML18093A487)
- 05000272/LER-1987-013-02, :on 871002,reactor Trip Occurred on Source Range Detector High Neutron Flux,Channel N31.Caused by Inadequate Design.Detector & Housing Associated W/Source Range Channel N31 Replaced + (ML18093A488)
- 05000272/LER-1987-012-02, :on 870930,Tech Spec 3.0.3 Entered Since Inoperable Undervoltage Trip Channel Not Placed in Tripped Condition within 1 H.Caused by Inadequate Relay Dept Procedures.Manual to Be Revised + (ML18093A490)
- ML18093A492 + (ML18093A492)
- 05000272/LER-1987-014-01, :on 871008,plastic Shoe Cover Found Wedged to Block Open Locked high-radiation Area Door Into Unit.Caused by Personnel Error.Door Closed & Locked as Required & Memo Issued Re Importance of Adhering to Controls + (ML18093A493)
- ML18093A494 + (ML18093A494)
- ML18093A495 + (ML18093A495)
- ML18093A496 + (ML18093A496)
- ML18093A499 + (ML18093A499)
- ML18093A500 + (ML18093A500)
- ML18093A501 + (ML18093A501)
- ML18093A502 + (ML18093A502)
- 05000311/LER-1987-014-02, :on 871022,setpoint on Diesel Generator Overcurrent Protection Relays Discovered Incorrect.Caused by Inadequate Documentation Control.Relays Corrected & Electrical Task Force Established + (ML18093A503)
- ML18093A504 + (ML18093A504)
- 05000272/LER-1987-015-01, :on 871023,fuel Moved from Core to Spent Fuel Pool in Support of Refueling Activities W/Two of Three Diesel Generators Inoperable.Caused by Personnel Error. Disciplinary Action Taken + (ML18093A505)