ML18093A501
| ML18093A501 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 11/20/1987 |
| From: | Zupko J Public Service Enterprise Group |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| NUDOCS 8711300070 | |
| Download: ML18093A501 (1) | |
Text
r n -*o PS~G tt Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station U. S. Nuclear Regulatory Conm1ission Document Control Desk Washington, DC 20555
Dear Sir:
SALEM GENERATING STATION LICENSE NO. DPR-75 DOCKET NO. 50-311 urnT N"O. 2 November 20, 1987 TECHNICAL SPECIFICATION SURVEILLANCE NOTIFICATION REQUIREMENT 4.4.6.5.a On November 11, 1987, five (5) tubes were plugged in Unit 2 No. 24 Steam Generator.
Two {2) of the tubes, located at row 33/column 55 and row 32/column 65, were plugged due to tube wall loss in excess of 40% (41% and 48% respectively).
The tube in location row 40/column 49 was plugged as a conservative measure due to a tube wall loss of 35%.
The other two tubes, located at row 1/colurnn 16 and row 1/column 37, were plugged due cold leg tangent cracking.
This notification* is being made as required by Technical Specification Surveillance 4.4.6.5.a within fifteen (15) days after tube plugging.
MJP:pc
,r---------
8711300070 97£120 -:.
PPDR ADOCK 05000311 PDR The Energy People Sincerely yours, Ouj~<J-J.~~- Zupko, Jr.
General Manager -
Salem Operations 95-2189 (11 M) 12-84