- ML17331A646 + (ML17331A646)
- IR 05000315/1980019 + (ML17331A648)
- ML17331A650 + (ML17331A650)
- IR 05000315/1980022 + (ML17331A652)
- 05000316/LER-1980-035-03, Rod Position Indication for Rod N-9 Did Not Respond Properly While Pulling Shutdown Control Rods in Preparation for Going Critical.Connector on Top of Rod Position Detector Assembly Appeared Stepped on + (ML17331A653)
- ML17331A654 + (ML17331A654)
- ML17331A657 + (ML17331A657)
- ML17331A658 + (ML17331A658)
- ML17331A659 + (ML17331A659)
- ML17331A660 + (ML17331A660)
- ML17331A661 + (ML17331A661)
- ML17331A664 + (ML17331A664)
- ML17331A665 + (ML17331A665)
- 05000316/LER-1981-001-04, No Apparent Flow Observed Through Radiation Monitor R-19 from Steam Generator 21. Caused by Bad Diaphragm in roto-meter Flow Regulator.Flow Meters to Radiation Monitor to Be Modified + (ML17331A666)
- ML17331A667 + (ML17331A667)
- 05000315/LER-1980-039, Forwards LER 80-039/03L-0,updated LER 80-034/03X-2 & + (ML17331A668)
- ML17331A670 + (ML17331A670)
- 05000316/LER-1980-034-03, Containment Isolation Valve NCR-252 Found Not Fully Seated W/Shut Indication in Control Room During Mode 5.Cause Undetermined.Valve Stroke Adjusted + (ML17331A671)
- 05000316/LER-1980-039-03, /03L-0:on 800728,low Pressure Alarm Failed to Clear W/Increased Nitrogen Pressure.Cause Not Stated.Refs Encl Response to IE Insp Repts 50-315/80-15 & 50-316/80-14 + (ML17331A672)
- ML17331A673 + (ML17331A673)
- ML17331A675 + (ML17331A675)
- ML17331A676 + (ML17331A676)
- ML17331A677 + (ML17331A677)
- IR 05000315/1980024 + (ML17331A680)
- ML17331A681 + (ML17331A681)
- ML17331A682 + (ML17331A682)
- ML17331A684 + (ML17331A684)
- ML17331A685 + (ML17331A685)
- ML17331A686 + (ML17331A686)
- ML17331A687 + (ML17331A687)
- ML17331A688 + (ML17331A688)
- 05000316/LER-1981-005-01, /01T-0:on 810331,spray Additive Tank Level Found Below Tech Spec Limit During Removal of Magnetrol for 18 Month Surveillance.Caused by Absence of Alarm Due to Contacts Wired Backwards.Tank Refilled + (ML17331A689)
- ML17331A691 + (ML17331A691)
- ML17331A692 + (ML17331A692)
- 05000316/LER-1981-006-03, /03L-0:on 810316,during Automatic Load Sequence Surveillance Test,Safety Injection Sys Relay Timers Exceeded Tolerance Allowed by Tech Specs.Caused by Instrument Drift. Component Cooling Water Pump 2E Timer Replaced + (ML17331A699)
- 05000316/LER-1981-007-03, /03L-0:on 810315 During Operation of 2CD Emergency Diesel in Preparation for Surveillance,Hot Starting Air Line Observed.Caused by Valve Damage & Exhaust Expansion Joint Inner Liner Failure.Intake & Exhaust Valves Replaced + (ML17331A700)
- ML17331A701 + (ML17331A701)
- ML17331A702 + (ML17331A702)
- 05000315/LER-1981-008-03, /03L-0:on 810317,large Piece of Herculite Found Securely Fastened in Canopy Fashion Over Walkway & Plastic Pail Found in Vicinity of Lower Ice Condenser Access Door. Cause Not Determined.Canopy Disassembled & Bucket Removed + (ML17331A703)
- IR 05000338/2018301 + (ML17331A704)
- ML17331A706 + (ML17331A706)
- ML17331A707 + (ML17331A707)
- ML17331A708 + (ML17331A708)
- ML17331A710 + (ML17331A710)
- ML17331A711 + (ML17331A711)
- ML17331A714 + (ML17331A714)
- NUREG-0674, Advises That Guard Training & Qualification Plan Does Not Meet Requirements of 10CFR73,App B.Requests Revision to 790817 Plan to Replace Pages 1-9 Through 1-17 Re Training Commitments.Response Should Be Submitted within 60 Days + (ML17331A715)
- ML17331A716 + (ML17331A716)
- ML17331A718 + (ML17331A718)
- 05000315/LER-1981-011-03, /03L-0:on 810413,while Examining Test Data from Type B & C Leak Rate Tests,Jul 1980 Test for Unit 1 Found to Have Exceeded Allowable Value of Tech Specs.Caused by Faulty NESW Check Valves.Valves Repaired + (ML17331A719)
- ML17331A720 + (ML17331A720)