- PNO-III-89-026, on 890409 & 10,circuit Breakers on Cd Diesel Generator Invertor Verified to Be in Closed Position. Licensee Investigation Concluded That Neither Mechanical Failure or Electrical Fluctuations Caused Breakers to Open + (ML17326B588)
- ML17326B589 + (ML17326B589)
- 05000316/LER-1989-002, :on 890116,seismic Restraint,Located on 24-inch ECCS Suction Line,Noted to Have Significant Deformation. Probably Caused by Removal & Reinstallation of Piping During Startup.Mod Initiated to Repair Restraint + (ML17326B590)
- 05000315/LER-1988-014, Withdraws LER 88-014-00 Re Incorrectly Routed Emergency Svc Water Cables Associated W/Pump Discharge Valve.Cables Have Been or Will Be Rerouted Per 10CFR50,App R + (ML17326B591)
- ML17326B593 + (ML17326B593)
- ML17326B594 + (ML17326B594)
- ML17326B595 + (ML17326B595)
- ML17326B596 + (ML17326B596)
- ML17326B598 + (ML17326B598)
- ML17326B600 + (ML17326B600)
- ML17326B601 + (ML17326B601)
- ML17326B602 + (ML17326B602)
- ML17326B603 + (ML17326B603)
- ML17326B604 + (ML17326B604)
- ML17326B606 + (ML17326B606)
- IR 05000315/1989004 + (ML17326B607)
- ML17326B609 + (ML17326B609)
- ML17326B611 + (ML17326B611)
- BSEP 17-0108, Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements + (ML17326B619)
- ML17328A002 + (ML17328A002)
- ML17328A005 + (ML17328A005)
- ML17328A007 + (ML17328A007)
- ML17328A009 + (ML17328A009)
- 05000315/LER-1989-004-01, :on 890324,discovered That Containment Type B & C Leakage Exceeded Limiting Condition for Operation.Caused by Degradation of Isolation Valve Seating Surfaces. Containment Isolation Valves Being Repaired + (ML17328A010)
- 05000315/LER-1989-003-01, :on 890318,ESF Actuation Occurred.Caused by Standing High Flux Trip on Intermediate Range Nuclear Instrumentation Channel I Which Had Not Reset Prior to Power Dropping Below Permissive P-10 + (ML17328A011)
- ML17328A012 + (ML17328A012)
- ML17328A016 + (ML17328A016)
- ML17328A017 + (ML17328A017)
- ML17328A019 + (ML17328A019)
- IR 05000315/1988028 + (ML17328A020)
- 05000315/LER-1989-006-01, :on 890405,discovered That Flow Rates for Safety Injection Pumps Exceeded Tech Spec 4.5.2.H Allowable Flow.No Cause Identified.Flow Control Values Adjusted to Meet Required Flows + (ML17328A021)
- 05000315/LER-1989-005-01, :on 890330,during Surveillance Testing, Containment Isolation Valve Would Not Close Per Tech Spec 3.6.3.1.Probably Caused by Flaw in Gear Tooth.Valve Operator Repaired by Replacing Defective Components + (ML17328A022)
- ML17328A024 + (ML17328A024)
- ML17328A026 + (ML17328A026)
- 05000316/LER-1989-009, :on 890331,discrepancy Noted in Westinghouse P-250 Computer Calculated Thermal Power Value Which Could Lead to Exceeding Rated Thermal Power.Caused by Not Including blowdown-mass Enthalpy Term + (ML17328A027)
- ML17328A028 + (ML17328A028)
- ML17328A029 + (ML17328A029)
- ML17328A032 + (ML17328A032)
- ML17328A033 + (ML17328A033)
- IR 05000315/1989015 + (ML17328A035)
- 05000315/LER-1989-007-01, :on 890414,Fire Door 422 in Demineralizer Valve Gallery,High Radiation Area Not Inspected Per Tech Spec 4.7.10.2a.Cause Not Stated.All Surveillances Assigned to Personnel Reconducted for Other Discrepancy + (ML17328A037)
- ML17328A038 + (ML17328A038)
- ML17328A040 + (ML17328A040)
- 05000315/LER-1989-008-01, :on 890420,power Range Neutron Flux Instrumentation Monthly Channel Functional Surveillance Test Procedures Do Not Satisfy Intent of Tech Spec 3.3.1.1.Caused by Lack of Specific Guidance.Rev Initiated + (ML17328A041)
- ML17328A042 + (ML17328A042)
- ML17328A043 + (ML17328A043)
- IR 05000315/1989014 + (ML17328A045)
- ML17328A046 + (ML17328A046)
- ML17328A047 + (ML17328A047)
- ML17328A048 + (ML17328A048)
- ML17328A049 + (ML17328A049)