ML17326B600

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Level III Examiner Personnel Not Certified Per ANSI N45.2.6-1978.Initially Reported on 890406.Stop Work Order Issued to Prevent Addl Insps from Being Performed by Unqualified Personnel & Qualification Procedure Revised
ML17326B600
Person / Time
Site: Cook  
Issue date: 04/10/1989
From: Weed J
QUALITY SERVICE INTERNATIONAL
To:
Office of Nuclear Reactor Regulation
References
REF-PT21-89-069-000 PT21-89-069-000, PT21-89-69, NUDOCS 8904210380
Download: ML17326B600 (7)


Text

ggc$ 1ZRATED 91 BUTION DEMONS

~TION SYSTEM REGULATOR.

INFORMATION DISTRIBUTION STEM (RIDS)

ACCESSION NBR:8904210380 DOC.DATE: 89/04/10 NOTARIZED: NO DOCKET FACIL Docket Unknown p5p*****

.AUTH.NAME AUTHOR AFFILIATION WEEDFJ.F.

AffiliationNot Assigned RECIP.NAME RECIPIENT AFFILIATION Office of Nuclear Reactor Regulation, Director (Post 870411

SUBJECT:

Part 21 rept re potential departure from the technical requirements included in procurement document.

DISTRIBUTION CODE:

IE19D COPIES RECEIVED:LTR

( ENCL L SIZE:

3 TITLE: Part 21 Rept (50 DKT)

NOTES:

RECIPIENT ID CODE/NAME LA PM INTERNAL: AEOD/DOA IRM TECH ADV NRR CRUTCHFIELD NRR/DEST/ADE 8H NRR/DLPQ/QAB 10 NRR VIB 9D G

RGNl RGN3 RGN5 EXTERNAL: INPO RECORD CTR NRC PDR COPIES LTTR ENCL 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD AEOD/DSP/TPAB IRM/DAB NRR VARGAFS NRR/DEST/ADS 7E NRR/DOEA/GCB 11

'NUDOCS-ABSTRACT RES/DSIR/EIB RGN2 RGN4 LPDR NSIC SILVERFE COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 0

0 1

1 R

l D

S A

NOXE 'IO ALL RIDS" RECIPIERIS:

PIZASE HELP US 'IO REDUCE HASTE!

CXÃI'ACI'IHEDOQJMWZ CXÃIBOL DESK KKN Pl-37 (EXT. 20079) m ELIIH32QLTE KKR NME PRGN DISX%GBVZION LISTS MR DOCUMEHIS YOU DONFT NEEDf D

S TOTAL NUMBER OF COPIES REQUIRED:

LTTR 25 ENCL 24

I

Quality Services International April 10, 1989 U.S. Nuclear Regulatory Commission Director of Nuclear Reactor Regulation One White Flint North 11555 Rockville Pike Rockville, Md 20852 Gentlemen:

Enclosed are three (3) copies of a written report required by 10CFR21.21 for notification of a potential departure from the technical requirements included in a procurement document.

Verbal notification of this potential departure has been made by me to Mr. William L. Forney, Deputy Director, Division of Reactor

Projects, NRC in Glen Ellen, IL on 4/6/89 at 1440. Should you have any questions concerning this written report, please feel free to contact Mr. Rod Witter, Quality Assurance
Manager, or myself at 419/535-9555.

Sincerely, Jack F. Weed President Enclosure JFW/mas 8'704210380 8'90410 PDR ADOCK 05000315 8

PDR yplf 5550 W. CentraI Avenue, Suite C, Toledo, OH 43515, 419/535.9555 QUALITYASSURANCE ~ TRAINING ~ ENGINEERING ~ TECHNICALCONSULTING

0 JT 4e

QU SERVICES INTIHPlATIONAL, C.

Page 1 of 2 POTEN~ 10CFR21 DEFECT WIGTTEN REPORT 10CFR21.21(b)(3)

Requirement 10CFR21 Requirement

Response

(i)

Name and address of the individual or individuals informing the Commission.

Mr. Jack F. Weed Quality Services International, Inc.

5550 W. Central Ave., Suite C Toledo, OH 43615 (ii)

Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a

defect.

ANSI N45.2.6 certification of Quality Control Inspection Personnel performing quality control inspections in an operating nuclear facility.

(iii)

Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.

Quality Control Inspection services being provided by: Quality Services International, Inc.(QSI) 5550 W. Central Ave., Suite C Toledo, Ohio 43615 (iv)

Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

Level III Examiner personnel were not certified according to the requirements of ANSI N45.2.6-1978 which may have lead to inadequate certification of Level II quality control inspection personnel who have performed quality control inspections of safety-related equipment at the D.C.

Cook Nuclear Plant.

(v)

The date on which the information of such defect or failure to comply was obtained.

April 6, 1989 (vi)

In the case of a basic component which contains a defect or fails to comply, the number and location of all such components in use at, supplied for, or being supplied for one or more facilities or activities subject to the regulations in this part.

These services have not been performed at any other 'acility.

(vii)

The corrective action which has been, is being or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

Corrective Action Taken

~

Stop Work has been issued by the client to prevent additional inspections from being performed until the personnel in question can be re-certified to an approved ANSI N45.2.6 program by a ANSI N45.2.6 certified Level III Examiner. (Completed 4/6/89 by American Electric Power Corporation)

~

QSI procedure for "Qualification of Examination, Inspection and Testing Personnel" has been revised to clarify Level III Examiner and Level II Inspection personnel certification requirements to ensure adherance to ANSI N45.2.6 - 1978 requirements. (Completed 4/7/89 by Jack Weed of QSI)

ci t~

c!

~

~

QU TY SERVICES INTERROGATIONAL,

'Page 2 of 2 POTENTIAL 10CFR21 DEFECT WRITTEN REPORT 10CFR21.21(b)(3)

Requirement 10CFR21 Requirement

Response

(vii)

(Continued)

~

QSI Level III Examiner has been recertified under'he revised certification program.

(Completed 4/7/89 by Jack Weed of QSI)

~

New Quality Assurance Manager has been assigned within QSI who has responsibility for iinplementing the QSI QA Program which includes certification of ANSI N45.2.6 inspection personnel.

(Completed 4/10/89 by Jack Weed of QSI)

~

Re-certify current Level II inspection personnel who are performing quality control inspection services at the D.C. Cook Nuclear Plant, according to the requirements of the revised certification program.

(Completed 4/10/89 by Rod Witter of QSI)

~

Verify that previous QSI inspection personnel who have performed quality control inspection services of safety-related equipment at the D.C. Cook Nuclear Plant were qualified to perform those inspections according to ANSI N45.2.6 - 1978 requirements.

(Being completed by American Electric Power Corporation)

(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

This potential defect is procedure-related and not substantive in nature. There is not a genuine concern being expressed by QSI regarding the qualifications of the inspection personnel in question as they have performed these same services as ANSI N45.2.6 certified Level II inspection personnel at a variety of other nuclear facilities throughout the industry before being certified by QSI to perform these same services at the D.C, Cook Nuclear Plant.

lf

~

g

~