Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000397/LER-1993-020, :on 930511,MSRV Position Indicators Not Tested Per TS Requirements Due to Poor Procedures,Inconsistency of Three Specs Re MSRVs & TS 3/4.3.7.5 for MSRV Acoustic Monitors Not Met at Required Times + (ML17290A446)
- GO2-93-158, Monthly Operating Rept for May 1993 for WNP-2 + (ML17290A447)
- ML17290A448 + (ML17290A448)
- ML17290A449 + (ML17290A449)
- IR 05000397/1993016 + (ML17290A452)
- ML17290A453 + (ML17290A453)
- ML17290A455 + (ML17290A455)
- 05000397/LER-1993-002, :on 930121,low RPV Level Reactor Scram Initiated by RPS in Response to Low Water Level Condition. Caused by Inadvertent Actuation of Deluge Sys.Plant Procedure PPM 8.3.120 Will Be Revised + (ML17290A456)
- 05000397/LER-1992-023, :on 930519,review of non-licensed Operator Tour Log Revealed Missed TS Surveillance & Fire Tour Data Due to Less than Adequate Work Practices.Investigation Into Event Expanded.No Violations Noted + (ML17290A458)
- 05000397/LER-1992-008-01, :on 920301,SGTS Fan Flow Limiter Setpoint Error Discovered.Caused by Analysis Deficiencies.Sgts Fan Flow Limiter Setpoint Changed & Rev 2 of Jco Approved W/New Offsite Dose Calculations + (ML17290A459)
- ML17290A461 + (ML17290A461)
- ML17290A464 + (ML17290A464)
- ML17290A466 + (ML17290A466)
- ML17290A467 + (ML17290A467)
- ML17290A468 + (ML17290A468)
- ML17290A470 + (ML17290A470)
- ML17290A472 + (ML17290A472)
- ML17290A474 + (ML17290A474)
- ML17290A475 + (ML17290A475)
- IR 05000397/1993014 + (ML17290A476)
- GO2-93-160, Requests Confirmation or Final Relief If Necessary Re Position That Would Exclude from 4 H Notification Requirement in 10CFR50.72(b)(2)(vi) for Situations in Which Util Required to Report Certain Min Levels of Radioactivity + (ML17290A477)
- GO2-93-138, Forwards Rev 16 to WPPSS-QA-004, Operational QA Program Description + (ML17290A478)
- ML17290A482 + (ML17290A482)
- ML17290A483 + (ML17290A483)
- 05000397/LER-1992-037-02, Forwards LER 92-037-02.Rev Provides Updated Info Re C/As for Manual Reactor Scram Due to Core Instability.Commitment to Obtain Amend to TS to Eliminate Requirements for Calculating T Deleted.Confusion Eliminated Through Trai + (ML17290A485)
- ML17290A487 + (ML17290A487)
- GO2-93-164, Revises 930413 Response to GL 92-08 Re Thermo-Lag 330-1 Fire Barriers.Schedule for Actions Necessary to Complete Activity Encl + (ML17290A489)
- 05000397/LER-1992-034, :on 920713,determined That Nonwater Tight Penetration Seals in ECCS Pump Rooms Could Result in Common Mode Failure from Flooding.Inadequate Penetration Seals in ECCS Pump Rooms Except for Door Seals Reworked + (ML17290A490)
- ML17290A491 + (ML17290A491)
- GO2-93-165, Corrects Info in Util Re Annual Reporting Requirements for Level of Financial Protection.Listed Property & Liability Insurance Coverage in Force at Facility + (ML17290A492)
- 05000397/LER-1992-034-02, Forwards LER 92-034-02.Supplemental Rept Describes Completion of Penetration Seal Rework & Changes to Flood Watch Requirements + (ML17290A494)
- GO2-93-166, Forwards Revised ISI Program Relief Requests 2-ISI-001 & 2-ISI-010 to Be Implemented During Third Insp Period of First Insp Interval.Ge Coverage Repts for R-8 & R-7 & Coverage Plot for N3 - Main Steam Also Encl + (ML17290A497)
- 05000397/LER-1993-023, :on 930605,concluded That Flexible Conduit Associated W/Pressure Switches Not Seismically Supported. Caused by Improper Construction Instructions.Walkdown of Quality Class I Racks Performed + (ML17290A499)
- 05000397/LER-1993-009, :on 930217,existence of Noncondensible Gases in Reference Leg of RPV Instrumentation Due to Design Deficiency.Procedures Developed & Revised & Evaluation Performed + (ML17290A500)
- 05000397/LER-1991-010, :on 910422,inability to Isolate Primary Containment Due to Wiring Separation Error Caused by Inadequate Work Instructions.Initiated Hourly Fire Tour for Accessible Areas + (ML17290A501)
- ML17290A504 + (ML17290A504)
- ML17290A506 + (ML17290A506)
- IR 05000397/1993007 + (ML17290A507)
- GO2-93-178, Responds to NRC Re Violations Noted in Insp Rept 50-397/93-13.C/As:licensee Will Conduct Followup Audits No Later than 930901,assessing Plant Personnel Performance Re Surveillance Procedure Documentation & Procedure Adherence + (ML17290A508)
- ML17290A509 + (ML17290A509)
- ML17290A511 + (ML17290A511)
- ML17290A512 + (ML17290A512)
- GO2-93-176, Monthly Operating Rept for June 1993 for Wnp,Unit 2.W/ Undated Ltr + (ML17290A513)
- GO2-93-180, Application for Amend to License NPF-21,increasing Licensed Power Level from 3,323 Mwt to 3,486 Mwt W/Extended Load Line Limit & Changing Safety Relief Valve Setpoint Tolerance. Proprietary ...Power Uprate W/Extended Load... Encl + (ML17290A515)
- ML17290A518 + (ML17290A518)
- 05000397/LER-1993-024, :on 930615,ESG Actuation of Containment Instrument Air Backup Nitrogen Bottle Programmer Occurred. Caused by Personnel Error & Procedure Deficiency.Test Procedures to Be Strengthened + (ML17290A520)
- 05000397/LER-1993-025, :on 930615,Group 1 Nuclear Steam Supply Shutoff Sys Isolation Occurred During Performance of TS Surveillance Test on Turbine Throttle Valves.Caused by Procedure Deficiency.Procedure Changed + (ML17290A521)
- ML17290A522 + (ML17290A522)
- IR 05000397/1993027 + (ML17290A524)
- ML17290A525 + (ML17290A525)
- ML17290A526 + (ML17290A526)