Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- GO2-90-157, Responds to NRC Re Violations Noted in Insp Rept 50-397/90-16.Corrective Action:Oil in Motors for SW-P-1A, SW-P-1B & HPCS-P-2 Replaced W/Lubrication Oil as Recommended by Motor Mfg + (ML17286A329)
- GO2-90-158, Revises Requests for Exemption from 10CFR55.45(b)(2)(iii) Re Filing Deadline & 10CFR55.45(b)(2)(iv).Exemption Should Be Granted Until 920930 + (ML17286A330)
- GO2-90-162, Provides Final Response to NRC Bulletin 90-002, Loss of Thermal Margin Caused by Channel Box Bow + (ML17286A331)
- GO2-90-161, Amends Response to Generic Ltr 83-28,Item 2.2.2 & Generic Ltr 90-03 Re Vendor Interface + (ML17286A332)
- GO2-90-167, Forwards NPDES Waste Discharge Permit Issued by State of Wa + (ML17286A334)
- ML17286A335 + (ML17286A335)
- ML17286A336 + (ML17286A336)
- GO2-90-168, Application for Amend to License NPF-21,changing Tech Spec 3.3.4 Re ATWS Recirculation Pump Trip Sys Instrumentation + (ML17286A337)
- ML17286A338 + (ML17286A338)
- ML17286A339 + (ML17286A339)
- IR 05000397/1990022 + (ML17286A341)
- 05000397/LER-1990-018, :on 900904,ESF Actuation of Containment Instrument Air Sys Occurred as Result of Inadvertent Manual Relief Valve Blowdown.Manual Actuator Removed & Lighting Fixture Secured + (ML17286A342)
- ML17286A343 + (ML17286A343)
- ML17286A344 + (ML17286A344)
- ML17286A345 + (ML17286A345)
- ML17286A346 + (ML17286A346)
- ML17286A347 + (ML17286A347)
- IR 05000397/1990021 + (ML17286A349)
- GO2-90-169, Comments on Proposed Generic Ltr 88-20,Suppl 4, Individual Plant Exam of External Events for Severe Accident Vulnerabilities. Estimate for Cost of Review Does Not Seem to Take Into Account Performing Much of Work in-house + (ML17286A350)
- ML17286A351 + (ML17286A351)
- ML17286A353 + (ML17286A353)
- ML17286A354 + (ML17286A354)
- IR 05000397/1990017 + (ML17286A356)
- ML17286A357 + (ML17286A357)
- ML17286A358 + (ML17286A358)
- ML17286A359 + (ML17286A359)
- ML17286A360 + (ML17286A360)
- GO2-90-163, Submits self-assessment Rept Re Overall Effectiveness of Util Programs/Organizations for June 1989 to Jul 1990 + (ML17286A362)
- 05000397/LER-1990-020, :on 900917,util Determined Overheating of Control Cabinet Could Cause Diesel Generator Failure + (ML17286A371)
- ML17286A374 + (ML17286A374)
- GO2-90-178, Application for Amend to License NPF-21,revising Tech Spec 3.1.3.1 Re Actions for Inoperable Scram Discharge Vol Vent & Drain Lines + (ML17286A376)
- ML17286A377 + (ML17286A377)
- ML17286A379 + (ML17286A379)
- 05000397/LER-1990-021, :on 900925,operators Manually Scrammed Reactor After Experiencing Main Turbine Hydraulic Control Oil Pressure Problems + (ML17286A385)
- ML17286A392 + (ML17286A392)
- ML17286A396 + (ML17286A396)
- ML17286A399 + (ML17286A399)
- ML17286A401 + (ML17286A401)
- IR 05000397/1990016 + (ML17286A403)
- ML17286A407 + (ML17286A407)
- ML17286A409 + (ML17286A409)
- GO2-90-182, Forwards Status Rept on commerical-grade Dedication Process, Per Commitment in Response to Insp Rept 50-397/89-21 + (ML17286A414)
- GO2-90-184, Discusses Util Equipment Setpoint Methodology Program.Harsh Environ Calculations Delayed Until 910601 + (ML17286A417)
- ML17286A420 + (ML17286A420)
- ML17286A422 + (ML17286A422)
- IR 05000397/1990023 + (ML17286A426)
- ML17286A429 + (ML17286A429)
- GO2-90-187, Monthly Operating Rept for Oct 1990 for Washington Nuclear Plant 2 + (ML17286A433)
- GO2-89-122, Responds to Generic Ltr 89-08 Re erosion/corrosion-induced Pipe Wall Thinning.Long Term Pipe Wall Thinning Monitoring Program Implemented by Procedure 8.3.63 + (ML17286A435)
- ML17286A438 + (ML17286A438)
- IR 05000397/1990025 + (ML17286A441)