Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
IR 05000454/19990128 October 1999Insp Repts 50-454/99-12 & 50-455/99-12 on 990803-0916.One NCV Occurred.Major Areas Inspected:Operations,Engineering, Maint/Surveillance & Plant SupportBoric Acid
Ultimate heat sink
Locked High Radiation Area
Foreign Material Exclusion
Earthquake
IR 05000454/19990161 October 1999Insp Repts 50-454/99-16 & 50-455/99-16 on 990907-10.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control Program & Chemistry Instrument Quality Control Program
IR 05000454/199901530 September 1999Revised Pages Eight Through Eleven to Insp Repts 50-454/99-15 & 50-455/99-15,correcting Inaccuracies with Docket Numbers & Tracking Numbers
IR 05000454/199901417 September 1999Insp Repts 50-454/99-14 & 50-455/99-14 on 990823-27.No Violations Noted.Major Areas Inspected:Physical Security Program
ML20211P2008 September 1999Insp Repts 50-454/99-15 & 50-455/99-15 on 990824-26.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Exercise of EPNuclear Accident Reporting System
PNO-III-99-041, on 990902,employees at Station Reported Feeling Ground Motion Associated with Earthquake.Plant Staff Checked Plant Sys & Equipment & No Evidence of Damage Was Found3 September 1999PNO-III-99-041:on 990902,employees at Station Reported Feeling Ground Motion Associated with Earthquake.Plant Staff Checked Plant Sys & Equipment & No Evidence of Damage Was FoundEarthquake
IR 05000454/199901025 August 1999Insp Repts 50-454/99-10 & 50-455/99-10 on 990622-0802.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportSafe Shutdown
Boric Acid
Temporary Modification
Operability Assessment
IR 05000254/199901020 August 1999Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each SiteBoric Acid
IR 05000454/199900816 July 1999Insp Repts 50-454/99-08 & 50-455/99-08 on 990511-0621.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportStroke time
Anchor Darling
Pressure boundary leak
Operability Assessment
IR 05000454/19990044 June 1999Insp Repts 50-454/99-04 & 50-455/99-04 on 990330-0510.No Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance & Plant SupportSafe Shutdown
Boric Acid
High Radiation Area
Stroke time
Maintenance Rule Program
IR 05000454/199900728 May 1999Insp Repts 50-454/99-07 & 50-455/99-07 on 990517-20.No Violations Noted.Major Areas Inspected:Fire Protection Program,Aspect of Plant SupportSafe Shutdown
Fire Barrier
Fire Protection Program
IR 05000454/199900520 May 1999Insp Rept 50-454/99-05 on 990401-22.No Violations Noted. Major Areas Inspected:Adequacy of Licensee Programs, Procedures,Equipment & Supporting Documentation for ISI ProgramNondestructive Examination
Foreign Material Exclusion
Liquid penetrant
IR 05000454/199900619 May 1999Insp Repts 50-454/99-06 & 50-455/99-06 on 990419-23.No Violations Noted.Major Areas Inspected:Liquid & Gaseous Effluent Program,Radiological Environ Monitoring Program, Auditing Program & Outage ActivitiesGrab sample
Offsite Dose Calculation Manual
Met Tower
Annual Radiological Environmental Operating Report
Inattentive
IR 05000454/199900314 April 1999Insp Repts 50-454/99-03 & 50-455/99-03 on 990217-0329. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportTemporary Modification
Incorporated by reference
Locked High Radiation Area
Condition Adverse to Quality
Operability Assessment
IR 05000454/199900210 March 1999Insp Repts 50-454/99-02 & 50-455/99-02 on 990105-0216.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportStroke time
Temporary Modification
Operability Determination
Operability Assessment
IR 05000454/199900111 February 1999Insp Repts 50-454/99-01 & 50-455/99-01 on 990119-22.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage Circuit BreakersSafe Shutdown Earthquake
ML20199H88119 January 1999Notice of Violation from Insp on 981124-990104.Violation Noted:From 871029 to 981123,test Controls for Stroke Time Testing of AFW Pump Discharge Valves Were Not Properly EstablishedStroke time
IR 05000454/199802519 January 1999Insp Repts 50-454/98-25 & 50-455/98-25 on 981124-990104.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportStroke time
Temporary Modification
IR 05000454/199802430 December 1998Insp Repts 50-454/98-24 & 50-455/98-24 on 981130-1204.No Violations Noted.Major Areas Inspected:Ro & SRO Requalification Programs,Review of Training Administrative Procedures & Written & Operating Exam MatlJob Performance Measure
Systematic Assessment of Licensee Performance
IR 05000454/199802018 December 1998Insp Repts 50-454/98-20 & 50-455/98-20 on 981006-1123.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant SupportUltimate heat sink
Stroke time
Locked High Radiation Area
Foreign Material Exclusion
Operability Determination
Fire Protection Program
Operability Assessment
IR 05000454/199802317 December 1998Insp Repts 50-454/98-23 & 50-455/98-23 on 981116-17.No Violations Noted.Major Areas Inspected:Verification of Adequacy of Training to Plant Operators in Dealing with Fluctuations in Electric Grid Stability
IR 05000454/199802210 December 1998Partially Withheld Insp Repts 50-454/98-22 & 50-455/98-22 on 981116-20 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Selected Aspects of Physical Security Program & Testing of Licensee Access Control Equipment
IR 05000454/19980215 November 1998Insp Repts 50-454/98-21 & 50-455/98-21 on 981013-16.No Violations Noted.Major Areas Inspected:Alara Planning & Radiation Work Permit Programs & Whole Body Counting & Screening Programs
IR 05000454/19983013 November 1998NRC Operator Licensing Exam Repts 50-454/98-301(OL) & 50-455/98-301(OL) for Tests Administered on 980914-22.Out of Five License Applicants,One SRO Passed All Portions of Exam. Two RO & Two SRO Applicants Failed Portions of Exam
IR 05000454/199801929 October 1998Insp Repts 50-454/98-19 & 50-455/98-19 on 980825-1005.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant SupportForeign Material Exclusion
Operability Assessment
ML20153D77018 September 1998Notice of Violation from Insp on 980714-0824.Violation Noted:During 980616-18,AP 1100-3,Rev 11,inappropriate to Circumstances,In That Procedural Guidance Led to Belief That Main CR Ventilation Envelope Altered When CR Doors Opened
IR 05000454/199801718 September 1998Insp Repts 50-454/98-17 & 50-455/98-17 on 980714-0824.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & EngineeringForeign Material Exclusion
ML20236W20831 July 1998Notice of Violation from Insp on 980531-0713.Violation Noted:As of 980713,SF Storage Pool Design Would Not Have Prevented Inadvertent Draining Below 423 Feet 2 Inches
IR 05000454/199801631 July 1998Insp Repts 50-454/98-16 & 50-455/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Security Equipment Maint,Procedure & Records Review,Personnel Performance, Self Assessment & Previously Identified Issues
IR 05000454/199801431 July 1998Insp Repts 50-454/98-14 & 50-455/98-14 on 980531-0713. Violations Noted.Major Areas Inspected:Operations, Maint/Surveillance,Engineering & Plant SupportSafe Shutdown
Boric Acid
Ultimate heat sink
Operability Assessment
IR 05000454/199801522 July 1998Insp Repts 50-454/98-15 & 50-455/98-15 on 980706-09.No Violations Noted.Major Areas inspected:follow-up of April 1997 Maintenance Rule Baseline Insp That Reviewed Licensee Implementation of 10CFR50.65Mission time
Emergency Lighting
Maintenance Rule Program
ML20236H02929 June 1998Notice of Violation from Insp on 980407-0530.Violation Noted:On 980502,OOS 970012670 Not Sufficient to Isolate Equipment Being Worked on
ML20236H03229 June 1998Insp Repts 50-454/98-11 & 50-455/98-11 on 980407-0530. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant SupportBoric Acid
Missed surveillance
Pressure and Temperature Limits Report
ML20248C04428 May 1998Notice of Violation from Insp on 980403-27 & 0506.Violations Noted:Radiologically Posted Area Established for sodium-24 Used in Moisture Carryover Test Was Not Posted W/Sign Bearing Radiation Symbol & Listed Words
IR 05000454/199801028 May 1998Insp Repts 50-454/98-10 & 50-455/98-10 on 980403-27 & 0506. Violations Noted.Major Areas Inspected:Review of Radiation Protection ProgramHigh Radiation Area
Inattentive
ML20248B09326 May 1998Notice of Violation from Insp on 980415-0508.Violation Noted:Ffd Program Was Not Appropriately ImplementedFitness for Duty
IR 05000454/199801326 May 1998Insp Repts 50-454/98-13 & 50-455/98-13 on 980415-0508. Violations Noted.Major Areas Inspected:Plant SupportFitness for Duty
ML20248C72721 May 1998Errata to Notice of Violation from Insp on 980113-0223 W/Combined ViolationsForeign Material Exclusion
Fire Protection Program
ML20217R0145 May 1998Insp Repts 50-454/98-09 & 50-455/98-09 on 980223-0406. Violations Noted.Major Areas Inspected:Operation, Maint Surveillance & Plant SupportHigh Radiation Area
Foreign Material Exclusion
Coast down
ML20217Q9675 May 1998Notice of Violation from Insp on 980224-0406.Violations Noted:Unit 1 Changed Operational Mode from Mode 5 to Mode 4 When Conditions for LCO of TS 3.4.6.1.b Were Not Met & Associated Action Required Shutdown within Specified Time
ML20217E86727 March 1998Insp Repts 50-454/98-04 & 50-455/98-04 on 980120-0210. Violations Noted.Major Areas Inspected:Engineering,Technical Support & Self Assessment ActivitiesSafe Shutdown
Loop seal
Packing leak
Ultimate heat sink
Fire Protection Program
ML20217E84227 March 1998Notice of Violation from Insp on 980120-0210.Violation Noted:On 960607,team Identified That Field Change Request (Fcr) 960062 Was Not Subjected to Design Control Measures Commensurate W/Measures Applied to Original DesignCondition Adverse to Quality
Fire Protection Program
ML20217E55026 March 1998Insp Rept 50-454/97-21 on 970919-980228.Violations Noted. Major Areas Inspected:Observations of Operations Training, Preparation for SG Replacement,Maint/Construction Activities & Review of Engineering & Quality AssuranceNondestructive Examination
Foreign Material Exclusion
Liquid penetrant
Dissimilar Metal Weld
Locktite
ML20217E52626 March 1998Notice of Violation from Insp on 970919-980226.Violations Noted:Licensee Contracted Level II Liquid Penetrant Exam Examiner Incorrectly Performed Liquid Penetrant Exam of SGNondestructive Examination
Liquid penetrant
IR 05000454/199800820 March 1998Insp Repts 50-454/98-08 & 50-455/98-08 on 980302-06. Violations Noted.Major Areas Inspected:Transportation & Solid Radioactive Waste ProgramsGrab sample
Foreign Material Exclusion
ML20217D10320 March 1998Notice of Violation from Insp on 980302-06.Violation Noted: on 980306,chemistry Technician Failed to Close Valve V8 Before Withdrawing 2 Gas Samples from Panel for Hydrogen & Isotopic Analyses
ML20248L81616 March 1998Notice of Violation from Insp on 980113-0223.Violations Noted:On 980117,plant Administrative Procedure 330-1,section c.b.c.4,not Implemented & on 970910,licensee Operated Gwps Differently from Ufsar,Section 11.3.2.1Foreign Material Exclusion
Fire Protection Program
IR 05000454/199800516 March 1998Insp Repts 50-454/98-05 & 50-455/98-05 on 980113-0223. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant SupportForeign Material Exclusion
Operability Assessment
IR 05000454/199800713 March 1998Insp Repts 50-454/98-07 & 50-455/98-07 on 980217-25.No Violations Noted.Major Areas Inspected:Various Aspects of Physical Security Program
IR 05000454/199800617 February 1998Insp Repts 50-454/98-06 & 50-455/98-06 on 980120-23 & 26. Noncited Violation Identified.Major Areas Inspected:Review of Radiation Protection ProgramHigh Radiation Area
Scaffolding