Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
L-PI-23-034, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System,2 January 2024Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System,
L-PI-23-035, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report20 December 2023Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits ReportHydrostatic
Nondestructive Examination
Pressure and Temperature Limits Report
L-PI-23-033, Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 35 December 2023Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3Safe Shutdown
Surveillance Frequency Control Program
Offsite Circuit
ML23262B03719 September 2023Response to NRC Request for Additional Information Regarding the 2023 Monticello and Prairie Island Plant Decommissioning Funding Status Reports
L-PI-22-034, Response to RAI, Alternative RR-08 Related to Pressure Isolation Valve Monitoring and Testing14 July 2022Response to RAI, Alternative RR-08 Related to Pressure Isolation Valve Monitoring and Testing
ML22161A91510 June 2022and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Response to a Request for Additional Information Xcel Energy Amendment Request to Create a Common Emergency Plan and Emergency Operations.Safe Shutdown
Health Physics Network
Offsite Dose Calculation Manual
Earthquake
Minimum staff
Fire Protection Program
Grace period
L-PI-22-033, Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles10 June 2022Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles
L-PI-21-047, Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 27 December 2021Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 2Fire Protection Program
L-PI-21-045, Response to Request for Additional Information Cooling Water System License Amendment Request4 November 2021Response to Request for Additional Information Cooling Water System License Amendment Request
L-PI-21-032, Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie Island30 September 2021Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie IslandShutdown Margin
Recently irradiated fuel
L-PI-20-026, Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiativ1 September 2020Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4Safe Shutdown
High Radiation Area
Mission time
Fire Barrier
Safe Shutdown Earthquake
Internal Flooding
Probabilistic Risk Assessment
FLEX
Fukushima Dai-Ichi
Surveillance Frequency Control Program
Large early release frequency
L-PI-20-023, Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI)10 June 2020Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI)Tornado Missile
Safe Shutdown Earthquake
Finite Element Analysis
FLEX
Aging Management
Earthquake
Fuel cladding
ML20045E89414 February 2020Response to a Request for Additional Information for Proposed 10 CFR 50.55a(z)(2) Alternatives to Utilize ASME Code Case N-786-3, Alternative Requirements for Sleeve Reinforcement of Class 2 and 3 Moderate-Energy Carbon Steel Piping, and AS
ML20127J0007 November 2019Xcel Reply to PIIC Expansion Application
L-PI-19-037, Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals16 September 2019Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals
L-PI-19-029, Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For...5 August 2019Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For...High winds
Internal Flooding
Probabilistic Risk Assessment
Large early release frequency
L-PI-19-014, Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors29 April 2019Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power ReactorsHigh winds
Internal Flooding
Probabilistic Risk Assessment
FLEX
Large early release frequency
L-PI-18-063, Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 8056 December 2018Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 805Safe Shutdown
Mission time
L-PI-18-051, Response to Request for Additional Information: Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program17 September 2018Response to Request for Additional Information: Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled ProgramProbabilistic Risk Assessment
Large early release frequency
L-PI-18-038, Supplement to License Amendment Request to Revise License Condition Associated with Implementation of NFPA 80510 July 2018Supplement to License Amendment Request to Revise License Condition Associated with Implementation of NFPA 805Probabilistic Risk Assessment
Fire Protection Program
ML18131A22311 May 2018Prairie and Monticello - Response to Request for Additional Information Regarding Proposed Alternative to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Di
L-PI-17-042, Response to Request for Additional Information Regarding License Amendment Request to Revise the NDE Inspection Interval for Special Lifting Devices6 November 2017Response to Request for Additional Information Regarding License Amendment Request to Revise the NDE Inspection Interval for Special Lifting DevicesNondestructive Examination
Liquid penetrant
ML17279A1214 October 2017Enclosure 2 to L-PI-17-041, Westinghouse-Prepared RAI Responses CE-17-3, Rev. 1, Attachment 2 and Enclosure 3, Marked-Up Technical Specification Page 4.0-7
L-PI-17-035, License Amendment Request to Revise the Emergency Action Level (EAL) Scheme - Supplement and Response to Requests for Additional Information27 September 2017License Amendment Request to Revise the Emergency Action Level (EAL) Scheme - Supplement and Response to Requests for Additional InformationSafe Shutdown
Time of Discovery
High winds
Reactor Vessel Water Level
Ultimate heat sink
Offsite Dose Calculation Manual
Fire Barrier
Safe Shutdown Earthquake
Internal Flooding
Probabilistic Risk Assessment
Operating Basis Earthquake
Operator Manual Action
Spent Fuel Pool Instrumentation
Safeguards Contingency Plan
Earthquake
Fuel cladding
Pressure Boundary Leakage
Grace period
Backfit
Unidentified leakage
L-PI-17-032, Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Plan Staff Augmentation Response Times20 September 2017Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Plan Staff Augmentation Response TimesHigh Radiation Area
Probabilistic Risk Assessment
Job Performance Measure
L-PI-17-007, Response to Request for Additional Information on License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors6 March 2017Response to Request for Additional Information on License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water ReactorsHot Short
Probabilistic Risk Assessment
Thermoset
Large early release frequency
L-PI-17-002, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.8.7 to Remove Non-Conservative Required Action16 February 2017Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.8.7 to Remove Non-Conservative Required ActionSafe Shutdown
Anticipated operational occurrence
Emergency Lighting
L-PI-16-100, Response to NRC Request for Information - License Amendment Request for Spent Fuel Pool Criticality Technical Specification Changes16 February 2017Response to NRC Request for Information - License Amendment Request for Spent Fuel Pool Criticality Technical Specification Changes
L-PI-16-090, Response to Request for Additional Information on License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors14 December 2016Response to Request for Additional Information on License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water ReactorsHot Short
Safe Shutdown
Fire Barrier
Probabilistic Risk Assessment
Large early release frequency
Fire Protection Program
Fire Watch
Very Early Warning Fire Detection
ML16351A21013 December 2016External Flooding Assessment Focused Evaluation. (Redacted)Fukushima Dai-Ichi
Flooding Focused Evaluation
ML16288A09714 October 2016and Monticello - Response to Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools
L-PI-16-076, Supplement to the Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 2, Flood Hazard Reevaluation Report29 September 2016Supplement to the Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 2, Flood Hazard Reevaluation ReportHydrostatic
Fukushima Dai-Ichi
ML16279A47929 September 2016Flood Hazard Reevaluation Report - Response to Requested Information
L-PI-16-067, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors- Response to Request for Additional Information17 August 2016License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors- Response to Request for Additional InformationSafe Shutdown
Probabilistic Risk Assessment
Multiple Spurious Operation
Thermoset
Large early release frequency
Fire Protection Program
Very Early Warning Fire Detection
L-PI-16-063, Seventh Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events17 August 2016Seventh Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External EventsSafe Shutdown Earthquake
FLEX
Fukushima Dai-Ichi
Spent Fuel Pool Instrumentation
B.5.b Mitigating Strategies
L-PI-16-005, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors - Response to Request for Additional Information24 May 2016License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors - Response to Request for Additional InformationHot Short
Safe Shutdown
Unanalyzed Condition
Fire Barrier
Probabilistic Risk Assessment
Large early release frequency
Fire Protection Program
Fire Watch
Weak link
ML16144A80623 May 2016Supplement to License Amendment Request for Spent Fuel Pool Criticality Technical Specification Changes: Response to RAI-2 (Enclosure 1) & Marked-Up Technical Specification Page (Enclosure 2)
L-PI-16-040, Supplement to License Amendment Request for Spent Fuel Pool Criticality Technical Specification Changes: Westinghouse-Prepared Response to RAI, CE-16-237, Attachment 2 (Enclosure 4)23 May 2016Supplement to License Amendment Request for Spent Fuel Pool Criticality Technical Specification Changes: Westinghouse-Prepared Response to RAI, CE-16-237, Attachment 2 (Enclosure 4)
ML16133A0419 May 2016Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 2, Flood Hazard Reevaluation ReportFukushima Dai-Ichi
L-08-001, Response to Requests for Additional Information - License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2, Using the Consolidated..14 April 2016Response to Requests for Additional Information - License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2, Using the Consolidated..
L-PI-16-029, Response to Requests for Additional Information - License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2,,Using the Consolidated..31 March 2016Response to Requests for Additional Information - License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2,,Using the Consolidated..Past operability
L-PI-16-004, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors- Response to Request for Additional Information20 January 2016License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors- Response to Request for Additional InformationSafe Shutdown
Fire Barrier
Probabilistic Risk Assessment
Thermoset
L-PI-16-001, Enclosure 2: Responses to Open and Pending Items from the NRC Audit Report14 January 2016Enclosure 2: Responses to Open and Pending Items from the NRC Audit ReportHigh winds
Shutdown Margin
Tornado Missile
Safe Shutdown Earthquake
FLEX
Design basis earthquake
Spent Fuel Pool Instrumentation
B.5.b Mitigating Strategies
Earthquake
L-PI-15-105, License Amendment Request (LAR) to Revise Technical Specifications (TS) to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process - Response to Request..30 December 2015License Amendment Request (LAR) to Revise Technical Specifications (TS) to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process - Response to Request..
L-PI-15-052, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors - Response to Request for Additional Information - 90-Day Responses19 June 2015License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors - Response to Request for Additional Information - 90-Day ResponsesHot Short
Safe Shutdown
Fire Barrier
Probabilistic Risk Assessment
Coatings
Multiple Spurious Operation
Thermoset
Foreign Material Exclusion
Cable Tray Ignition
Maintenance Rule Program
Fire Protection Program
Fire Watch
Very Early Warning Fire Detection
L-PI-14-113, Updated Final Response to NRC Request for Information Per 10CFR50.54(f) Re Seismic Aspects of Recommendation 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident16 January 2015Updated Final Response to NRC Request for Information Per 10CFR50.54(f) Re Seismic Aspects of Recommendation 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi AccidentFukushima Dai-Ichi