 Issue dateTitleTopic
ML20140A47627 May 1997Provides Addl Info to 970429 Part 21 Rept Re Potential safety-related Problem W/Asco HV 266000-007J Scram Solenoid Pilot Valves.Corrective Actions Also Listed
ML20059H77217 January 1994Part 21 Rept Re Virginia Power Notifying Fairbands Morse Via Failure Analysis Rept NESML-Q-058 of Defective Air Start Distributor cam,16104412
ML20059F2637 January 1994Part 21 Rept Re Air Start Distributor Cam Mfg by Fairbanks Morse.Mfg Suggests That Site Referenced in Encl App I Inspect Air Start Distributor Cam as Soon as Practical
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20118B43911 September 1992Part 21 Rept Re Degradation in Abb Type 27N Undervoltage Relays Used in Electrical Switchgear.Recommends That Users Review Applications Requiring Exposures Greater than 1E03 Rads TID W/Time Delay Function Option
ML20096F59211 May 1992Followup to 920417 Part 21 Rept 10CFR21-0062 Re Failed Shaft in DG W/Emd 645 Series Engines Using Turbochargers Remanufactured from May 1991 to Jan 1992.Turbochargers Should Be Removed & Returned to EMD for Insp/Repair
ML20043A60927 April 1990Part 21 Rept Re Defective Axial Cracks in Pump Shaft in Region Immediately Above Impeller & in Reactor Recirculation Pumps.Probably Caused by Crack Growth as Thermal Fatigue. Technical Advisory Bulletin Will Be Sent to Each Util
ML20005G6835 January 1990Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced
ML20247D30112 July 1989Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified
ML20246K74026 April 1989Part 21 Rept Re Incorrectly Stamped Name Plates on Certain Asco Nuclear Qualified Valves.Vendor Will Contact Each Affected Facility & Furnish Correctly Stamped Plates & in Near Future Discontinue Sale of Rebuild Kits for Valves
ML20207N46412 October 1988Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20205T64510 June 1986Part 21 Rept Re Defect in GE Type Sbm Control Switch Intended for Use in Alternate Shutdown Sys.Defective Switch Rejected & Returned to Vendor.Remaining Switches Examined. Corrective Action Rept M-36 Issued to United Controls,Inc
ML20141D8051 April 1986Part 21 Rept Re Model 402 Series Level Control Used for safety-related Application Shipped W/O Torque Check. Customers Will Be Notified by 860428 & Requested to Perform Torque Check.List of Plants Using Component EnclEarthquake
ML20140A52819 December 1985Part 21 Rept Forwarding Ltr Sent to Customers Re Check Valves Missing Lock Welds on Hinge Supports or Hinge Support Capscrews,Per 851121 Request.List of Customers Receiving Ltr Also Encl
ML20134Q17429 August 1985Part 21 Rept Re Potential Maint Issues Associated w/Anker-Holth Snubbers.Owners of Anker-Holth Snubbers Will Be Informed of Problems & Sent Revs to Technical Instruction Manuals to Include Procedures for Seal & Fluid Maint
ML20210G99213 August 1985Part 21 Rept Re Failure of Isolated Worm Shaft Gear When Certain Critical Speeds Combined W/Repetitive Transfer of Actuator Clutch Mechanism from Manual (Handwheel) to Motor Drive Mode.Two Possible Solutions Noted
ML20116N6143 May 1985Part 21 & Deficiency Rept SSH-M-85/01 Re Defective Circuit Breakers for Recombiners Supplied by Rockwell Intl.Initially Reported on 841124.Equipment Deficiencies Corrected Prior to Installation.Rockwell Intl Requested to Follow Up Action
ML20113A42911 January 1985Part 21 Rept Re Incorrect Insulating Tape.Instructions Governing Handling of Incoming Matls Fully Adequate & If Followed,Would Have Prevented Error
ML20095G60122 August 1984Part 21 Rept Re Defects in 18-inch SA-333 RHR Pipe.Samples of Defective Pipe Matl Being Shipped to Techninat Corp,Per Request.Defects Located in One Length of SA-333 Grade 6 Pipe
ML20090H85020 July 1984Supplemental Part 21 Rept Re Two Laminar Type Discontinuties Noted in Tioga Pipe Supply Co 18-inch Carbon Steel Pipes. Corrective Action Rept M-27 Issued to Bechtel on 840705 Requesting Identification of Cause
ML20077H7054 August 1983Part 21 Rept Re 75 Components (Part P2073A) Lacking Conformance to Specs for Size & Fusion.Initially Reported on 830718.Conditions Which Allowed Erroneous Shipment Corrected
ML20083L97527 May 1983Part 21 Rept Re Failure of Circuit Breakers During Environ Testing.Test Results Indicate That Temp Sensitivity Problem May Be Generic to All Ite Imperial Corp thermal-magnetic Circuit Breakers Calibr for 40 C Svc
ML20090L5213 October 1974Significant Deficiency Rept SDR5 Re High Pressure Svc Water Valve Weld Failure.Initially Reported on 730601.Vendor Weld Stress Analysis Calculations Reviewed & Table of Acceptable Weld Sizes Prepared
ML20090L7291 October 1974Deficiency Rept Re Potential Seal Failures Found in Bergen-Paterson Snubbers Installed at Several Bwrs.Fittings W/Ethylene Propylene Flaps Made Available for Future Snubber Maint