.j) hl. h g INTE R N ATIO N A LMAGNETRO 5300 Belmont Road + oowners Grove. Ilhnois 605154499 + (312) 9694000
- Teien 25@85 REGISTERED RETURN RECEIPT REQUIRED April 1, 1986 Director - Region III Office of Inspection and Enforcement U. S. Nuclear Regulatory Comission Building Number 4 799 Roosevelt Road Glen Ellyn, IL 60137
Dear Sir:
Pursuant to the requirements of 10CFR, Part 21, Reporting of Defects and Non-Compliance, attached is a report made by Magnetrol's Deviation Evaluation Board.
This report details a product defect found by audit at the TVA Brown's Ferry Plant; and, provides a list of users of identical or similar items.
Further, this report identifies Magnetrol's action to remedy the defect; and, notify the nuclear facilities.
Sincerely,
/.JE5 Dennis K. Frantzen Contract Administrator i
for Mr. R. A. Lamz, Executive Vice President DKF/ls Enc: Report 0604os0277ep4yi9 ADOCK O PDR PDR l
S l
.APR 2 1986 I
LEVEL AND FLOW INSTRUMENT /. TION
INTEROFFICE CORRESPONDENCG C0 pats to:
IN T E R N ATIO N A L TU ATE R. A. Lamz March 31, 1986 ATTENTION FROM D. J. Stevenson SUBJECT DEVIATION EVALUATION BOARD MEETING RESULTS The Deviation Evaluation Board met on March 28, 1986 to discuss a defect delivered to Tennessee Valley Authority, Browns Ferry Plant.
The DEB has determined that this incident is reportable to the NRC under 10CFR Part 21.
The attached report describes the incident for you to prepare your report to the NRC.
DJS/1s hl 4-[t [FG
?:os AM 4kB E
N MAGNETROL INT E R N ATIO N A L DEVIATION EVALUATION BOARD MEETING BASIC COMP 0NENT: Model 402 Series Level Control used for Nuclear Safety Related Application DEFECT: Non-Compliance:
The Seismic Qualification requires that the enclosing tube nut should be torqued to 200/225 foot /lbs.
Model 402 Series controls have been shipped to customers with-out the torque check.
Without the proper torque, the enclosing tube nut could loosen during a seismic event causing a leak; or, loss of pressure of the process fluid.
A list of customers is attached showing Model Number, Quantity and Serial Numbers.
Tennessee Valley Authority (Browns Ferry Plant) is already notified of this deviation; and, will respond with confirmation of corrective action by April 24, 1986.
Other customers will be notified by April 28, 1986; and, will be requested to confirm torque check in writing.
This condition is only a concern during or after earthquake induced vibrations.
There is no cause for concern during normal plant operation.
i
w,,
MAGNETROL INTE A N ATION A L Tennessee Valley Authority Purchase Order: 82PJ9-829022 Browns Ferry Nuclear Plant Production No: C156312-101 Unit 1, 2, & 3 Model: 402-EP/VPX-S1MD4H Section VIII Athens, AL 35611 Quantity: 12 Serial No's: 777753-764 Purchase O'rder: 85PK6-343692 Production No: C203298 Model: 402-EP/VPX-S1MD4H Section VIII Quantity: 10 Serial No's: 918709-718 Northeast Nuclear Energy Co.
Purchase Order: 811270 Millstone NPS Unit #1 Production No: C157368-101 Section III No Stamp Waterford, CT 06385 Model: 402-X-EP/VPX-M14H Quantity: 14 Serial No's: 844201-214 Commonwealth Edison Co.
Purchase Order: 257981 Quad Cities Production No: C135-203 Units 1, 2, & 3 Model: 402-EP/VPX-SIMD4H'Section VIII, Div. 1 Cordova, IL 61242 Quantity: 10 Serial No's: 777691-777700 Comonwealth Edison Co.
Purchase Order: 258071 Dresden Station Production No: C135-303 Units 2 & 3 Model: 402-EP/VPX-S1MD4H Section VIII, Div. 1 Morris, IL 60450 Quantity: 9 Serial No's: 777682-690 Northern States Power Co.
Purchase Order: 10040-J-478(Q)-AC Monticello Plant Production No: C137-101' Monticello, MN 55362 Model: 402-X-MPG-M14DC'Section VIII, Div. 1 Quantity: 7 Serial No's: 777713-719 GPU Nuclear Corp.
Purchase Order: 201028 Oyster Creek N.G.S.
Production No: C158720 Forked River, NJ 08731 Model: 402-X-MPG-SIMD4DC Section VIII Quantity: 6 Serial No's: 777765-70 New York Power Authority Purchase Order: NY082263 (Formerly: Power Authority of the Production No:
C170438 State of New York)
Model: 402-EP/VPX-51MD4DC Lycoming, NY 13093 Quantity: 4 Serial No's:
836845-48 NOTE:
(2) spare units sold to NYPA under C218083; however, these were torque checked.