ML20095G601

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Defects in 18-inch SA-333 RHR Pipe.Samples of Defective Pipe Matl Being Shipped to Techninat Corp,Per Request.Defects Located in One Length of SA-333 Grade 6 Pipe
ML20095G601
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 08/22/1984
From: Crosby G
NORTHERN STATES POWER CO.
To: Jay Collins
NRC
References
REF-PT21-84-450-000 PT21-84-450, PT21-84-450-000, SPLM-754, NUDOCS 8408280127
Download: ML20095G601 (1)


Text

W Northem States Power Company Monticello Nuclear Generating Plant P.O. Box 600 Monticello, Minnesota 55362 August 22, 1984 U.S. Nuclear Regulatory Commission Washinton, D.C. 20555 Attn: Joe Collins Mail Stop EW359

Dear Mr. Collins:

MONTICELLO NUCLEAR GENERATING PLANT E-82M003 Recirculation System Piping Replacement 10CFR21 Report for Defects in 18 inch SA-333 RHR Pipe SPLM-754 In accordance with your request, we are shipping samples of the defective pipe material to: Techninat Corporation 2345 South 170th Street New Berlin, WI 53151 Attn: Manfred E. Cuess One piece from each defect is being shipped. The pieces are 6 x 12 inches minimum. Both defects were located in one length of SA-333 Grade 6 pipe.

If you have questions, please call me at (612) 295-1652.

Yours very truly, 1

l E Crosb Lead QA ngineer l GEC/tal cc: C. Brown NRC, Monticello P. Johnson P. Suleski (WVJ)

D. Musolf F. Tierney ,

File B000 l l

l 8408280127 840822 PDR ADOCK 05000263 i 9

S PDR c.