W Northem States Power Company Monticello Nuclear Generating Plant P.O. Box 600 Monticello, Minnesota 55362 August 22, 1984 U.S. Nuclear Regulatory Commission Washinton, D.C. 20555 Attn: Joe Collins Mail Stop EW359

Dear Mr. Collins:

MONTICELLO NUCLEAR GENERATING PLANT E-82M003 Recirculation System Piping Replacement 10CFR21 Report for Defects in 18 inch SA-333 RHR Pipe SPLM-754 In accordance with your request, we are shipping samples of the defective pipe material to:

Techninat Corporation 2345 South 170th Street New Berlin, WI 53151 Attn: Manfred E. Cuess One piece from each defect is being shipped. The pieces are 6 x 12 inches minimum. Both defects were located in one length of SA-333 Grade 6 pipe.

If you have questions, please call me at (612) 295-1652.

Yours very truly, l

E Crosb Lead QA ngineer GEC/tal cc:

C. Brown NRC, Monticello P. Johnson P. Suleski (WVJ)

D. Musolf F. Tierney File B000 8408280127 840822 PDR ADOCK 05000263 i 9 S

PDR c.