ML20236S09217 July 1998Audit Rept,Commitment Mgt for Tva,Sequoyah Nuclear Plants, Units 1 & 2Fire Protection Program
ML20138D18928 February 1997Special Project Rept Audit 97-901S, Concerns Resolution Program-Sequoyah Nuclear Plant
ML20138D23328 February 1997Special Project Rept Audit 97-920S, Concerns Resolution Program-TVA Nuclear, Feb 1997
ML20133F37214 January 1997Press Release II-97-08, NRC Staff Proposes $100,000 Fine Against TVA NRC Staff Also Prohibits TVA Executive from Involvement in NRC-Licensed Activities
ML20132G87426 December 1996Press Release II-96-105, NRC Staff Proposes $100,000 in Fines Against TVA at Sequoyah
ML20135D0746 December 1996Press Release II-96-100, NRC Staff to Hold Predecisional Enforcement Conference to Discuss Sequoyah Equipment Concerns W/Tva
ML20134L30120 November 1996Press Release II-96-97, NRC Staff Proposes $50,000 Fine Against TVA at SequoyahHigh Radiation Area
Hydrostatic
Fire Protection Program
Fire Watch
Scaffolding
ML20116J5226 August 1996Pressure Locking Evaluation for Required Pullout Force (for Double Disc Split Wedge)Weak link
ML20116J5256 August 1996Pressure Locking Evaluation for Required Pullout Force (for Double Disc Split Wedge)Weak link
ML20116J5366 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20116J5396 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20116J5446 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20116J5416 August 1996Pressure Locking Evaluation for Required Pullout ForceWeak link
ML20116J5176 August 1996Pressure Locking Evaluation for Required Pullout Force (for Double Disc Split Wedge)Weak link
ML20116J5156 August 1996Pressure Locking Evaluation for Required Pullout Force (for Double Disc Split Wedge)Weak link
ML20116J5096 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20116J5056 August 1996Pressure Locking Evaluation for Required Pullout ForceWeak link
ML20116J5026 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20116J4976 August 1996Pressure Locking Evaluation for Required Pullout Force
ML20058P13223 December 1993Package Containing Answers to Questionnaire Re Employee Concerns Programs
ML20065B78118 June 1993Degraded Voltage Analysis
ML20086H98527 November 1991Evaluation of Block Clamps at Welds Near Valves 0-67-1514 & 2-67-1513Weak link
ML20028G83621 August 1990Foundation Investigation of ERCW Pumping Station Foundation Cells.Operating Basis Earthquake
ML20029A0063 August 1990Rev 0 to SQN-00-D052 EPM-AMJ-073190, Fire Hazard Analysis of Unit 2 App R Cables in Boric Acid Tank Area,Elevation 690 Auxiliary Bldg.Safe Shutdown
Boric Acid
ML20042F25325 April 1990Instrument Accuracy Calculation 1LT-63-50,-51,-52 & -53 (RWST Switchover).
ML20042F25525 April 1990Instrument Accuracy Calculation 1LT-63-176,-177,-178 & -179 (RB Sump Switch).
ML20043H04311 April 1990Steel Containment Vessel - DBA Analysis Ccts Double Differentiation Question.Earthquake
ML20012C62920 February 1990Rev 2 to TVA Calculation SQN-SQS2-0097, Probabilistic Analysis Showing Effects of Deleting RHR Autoclosure Interlock.
ML20012A3033 January 1990Foundation Investigation Evaluation of ERCW Roadway Access Cells a & B.
ML20245J07812 July 1989Rev 3 to Best Estimate Evaluation of Ice Condenser Basket Weights for Sequoyah Unit 1 Cycle 4, Supporting 890620 Application for Amend to License DPR-77,consisting of Tech Spec Change Request 89-24
ML20154P41217 August 1988Rev 1 to Extension of Ice Condenser Weighing Period Based on Predicted Group - Row & Bay Sublimation Rates
ML20151A2581 July 1988Rev 0 to App R,Cable to Cable Shorts for RCS High/Low Pressure InterfacesHot Short
Safe Shutdown
Fire Watch
ML20195D66717 June 1988Nonproprietary App R Reactivity Calculations
ML20235X37916 September 1987Rev 1 to SQN-SQS4-0088, Justification for Continued Operation W/Unimplemented Corrective Actions for Moderate Energy Line BreaksSafe Shutdown
Fire Barrier
Internal Flooding
Probabilistic Risk Assessment
Condition Adverse to Quality
Earthquake
ML20151M96020 July 1987Package of NRC Administered Requalification Exam Results Summary
ML20211A0823 October 1986Package Consisting of Summary Schedule Suppl & Variance Rept & Capital Project Request Summary
ML20203H28528 July 1986Package of Documents Re Operating Experience W/Westinghouse PWR Steam Generators Through 820131Hydrostatic
IA-86-445, Package of Documents Re Operating Experience W/Westinghouse PWR Steam Generators Through 82013128 July 1986Package of Documents Re Operating Experience W/Westinghouse PWR Steam Generators Through 820131Hydrostatic
ML20134L58118 July 1985Package of Operator Exam Results Summary Sheets
IA-85-442, Package of Operator Exam Results Summary Sheets18 July 1985Package of Operator Exam Results Summary Sheets
ML20129F4839 May 1985Package of Compilations of Results of Operator Licensing & Requalification Exams
ML20009A8278 July 1981Viewgraphs Entitled TVA Inner Radius U-Bend Program, Presented at 810603 Meeting W/Nrc.Charts,Tables & Addl Info Encl
ML19248D3402 August 1979Const Deficiency Rept on 790802:chattering of Underfrequency Relay Contacts Caused Auxiliary Relay to Chatter,Delaying Reactor Trip & Cooling Pump Trip Signals.Relay & Design Changes Being Implemented
ML19242D16030 July 1979Possible RO on 790730 Re Failure to Seismically Qualify or Check Electrical Handholes in Conduit Between Auxiliary Bldg & Pump Station for Flow & Stress During Probable Max Flood
ML19242D23127 July 1979Notification of Potential Design requirement:3/4-inch Test Lines from 8-inch Low Head Safety Injection Headers Do Not Allow for Acceptable Piping Flexibility
ML19247A90817 July 1979Insp of Two Safety Injection Sys Accumulator Discharge Valves Revealed Severe Multiple Cracks in Stellite Facing. Notified Vendor,Velan Engineering Co.Possible Generic Implications to Unit 2 & Watts Bar