ML20203H285

From kanterella
Jump to navigation Jump to search
Package of Documents Re Operating Experience W/Westinghouse PWR Steam Generators Through 820131
ML20203H285
Person / Time
Site: Beaver Valley, Salem, Indian Point, Kewaunee, Point Beach, Sequoyah, Prairie Island, Surry, North Anna, Turkey Point, Haddam Neck, Ginna, Diablo Canyon, Farley, Robinson, San Onofre, Cook, Yankee Rowe, Zion, McGuire, 05000000, Trojan
Issue date: 07/28/1986
From:
NRC
To:
Shared Package
ML20203H178 List:
References
FOIA-86-445 NUDOCS 8608040361
Download: ML20203H285 (83)


Text

w

,,d

?

I TABLE 1

OPERATING EXPERIENCE WITH WESTINGHOUSE PWR STEAM GEIERATORS THROUGH JANUARY 1982 i

s i

Sec.

Prev.

Other Sec.

Prim. Side No.

SG Water Exp. w/

Corr. Ind.

Side Init. SCC of No.(5)

SG wall Thin.

Init, in Small Leak.

of Tubes Sleev e Replace-Na/PO,l Model OL Chem.

Contro West.

or Pit.

Fret.

IGA / SCC Rad. U-Bends centing(e)

Tubes Plugged Repal-s ment Plant Name No.

Date Control i

Yankee-Rowe (a)(b) 7/60 AVT Yes X

37 115(1.8%)

San Onofre 1 27 3/67 Na/PO Yes X

X X

X-Extensive 31 954 (8.4%)

X-7000 j

4 tubes l

4 69(0.5%)

Haddam Neck 27 12/74 AVT Yes I

X X

X-Minor l

Ginna 1 44 9/69 AVT Yes X

X X-Minor 6

228(3.65)

X-21 l

tubes 8:

H.B. Robinson 2 44 9/70 Na/PO Yes X

X X W nor

% 11%)

Under 4

consid.

Paint Beach 1 44 12/70 AVT Yes X

X X-Moderate 51 818(12.65) X-12 Planned tubes Fall '83 Paint Beach 2 44 11/71 AVT Yes X

X X-Moderate 4

117(21)

Planned Spr. '83 Surry 1 (c) 51 5/72 AVT Yes X

X-Extensive 40 2576 X-Cose.

(25.4%)

Turkey Point 3 44(g) 7/ 72 AVT Yes X

X-Extensive 14 2058(211)

In Prog.

Surry 2 (c) 51 1/73 AVT Yes X

X X-Extensive 27 2154(21%)

X-Comp.

^

Indian Point 2 44 9/73 AVT Yes X

X-Extensive 5

472 (3.611) 2606()24.8%

(f l

Planned Turkey Point 4 44(h) 4/73 AVT Yes X

X-Extensive 36 Zirn 1 51 4/73 AVT Yes X

X-Minor 1

26(.4%)

Prairie Island 1 51 8/73 AVT Yes X

X 2

34(15)

Kewaunee 51 12/73 AVT Yes X-Minor 0

0 Zitn 2 51 11/73 AVT Yes X-Minor 1

13(.2%)

Prairie Island 2 51 10/74 AVT No X

X X

1 61( 21)

Cook 1 51 10/74 AVT No 0

21(<l5) l 8608040361 860728 PDR FOIA CONNER 86-445 PDR

I 7

TABLE., ' -

OPERATING EXPERIENCE WITH WESTING 400SE PWR STEAM GENERATORS THNDUGH JMlUARY 1982_

i t

i !

e t

l Sec.

Prev.

Other Sec.

Prim. Side No.

58 Water Exp. w/

Corr. Ind.

Side Init. SCC of No. (1)

SG Model OL Chem.

Na/PO wall Thin.

Init.

In Santi Leak.

of Tubes Sleeve Replace-r Plait Name No.

Date Control Contr81

Wast, or Pit.

Fret.

IGA / SCC Rad. U-Bends centing(e)

Tubes Plugged Repairs ment g

Trojin 51 11/75 AVT No X

42 347 2.6%

I 4

Indian Point 3 44 12/75 AVT No X

X-Extensive 3

831 6.4%

Under constr.

I

']

Beavir Valley 1 51 1/76 AVT No 0

0 l

i Salem 1 51 8/76 AVT No X

X-Minor 0

53(0.4%)

Farley 1 51 6/77 AVT No X

8 282(2.8%

North Anna 1 51 11/77 AVT No X

X-Minor 1

284(2.8%

Cook 2 51 12/77 AVT No X

3 63(.4%)

l Syrry 2 (d;I 51 9/80*

AVT No Surry 1 (d,I 51 7/81*

AVT No l

North Anna 2 51 8/80 AVT No 0

282(2.8%)

l Sequryah 1 51 9/80 AVT No X-Minor 0

Sales 2 51 4/80 AVT No X

0 0

I 8D(051) 41)

McGuire 1 D2 1/81 AVT No X

5(.

Farlsy 2 51 10/80 AVT No 5

Sequoyah 2 51 9/81 AVT No X.

Diablo Canyon 1 51 9/81X, AVT -

No b

i s

fa;l No model number.

l

[b,1 Yankee Rowe esploys 304 SS tubing. All other PWRs employ Inconel-600 tubing.

1 c? Original steam generators.

]

lds Replacement steam generators.

l 1

i Definition of extensive vs. moderate onuninor denting is provided in Table 2.

I e!I Of the 472 tubes plugged. 384(2.941) were plugged during construction and only 87(.671) were plugged during operation.

J' f

[gl'l SG has been replaced with 44F as of 3/82.

Lhl SG will be replaced with 44F on 10/82.

XX Suspended 11/81.

o

  • Startup Date.

4 1

i

2 YANKEE-ROWE NUCLEAR POWER STATION STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 11/15/74 Letter granting an extension of time to file T.S.

for steam generator baseline tube inspection.

12/06/78 Amendment No. 54 to T.S. instituted a revised' steam generator ~1nservice inspection program.

7/21/80 Amendment No. 61 to T.S. added license condition regarding st'eam generator water chemistry controls.

6/06/81 Amendment No. 68'to T.S. authorized extension of time to perform' steam generator inservice inspection.

l

'~

i YANKEER0k--

l STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY Primary to No. Defects No. Tubes (3)(4)

Secon'dary Type of Requiring No. Tubes (1)

Date Inspected Leakage. ope (2)

Total Defects Degrad.

Reoair Plugged /Sieeved/ Pulled S.G. Nwser 1/2/3/4 1/2/3/4 1/2/3/4 1/2/3/4 4.17x10}I

-/-/9/1 b

-/-/9/1

-/-/9/1 3/67 0/0/1620/1620 7/67 1620/1620/0/0 2.1x10~3 1/1/-/-

b 1/1/-/-

1/1/-/-

8/69 1619/0/0/1619 2.9x10 j 1/-/-/3 b

1/-/-/3 1/-/-/3 3/70 1618/0/0/0 1.7x10~ j 3/-/-/-

b 3/-/-/-

3/-/-/-

8/70 1615/0/1611/0 7.4x10~

6/-/2/-

b 6/-/2/-

6/-/2/-

11/70 0/0/0/1615 5.4x10~2

-/-/-/3 b

-/-/-/3

-/-/-/3 11/70 0/0/0/75 5.4x10-2

-/-/-/21 b

-/-/-/5

-/-/-/5 i

11/71 1609/0/0/0 8.3x10-2 1/-/-/-

b 7/-/-/-

7/-/-/-

b 1/-/-/-

1/-/-/-

11/71 101/0/0/0 8.3x10~2 30/-/-/-

7/74 0/0/0/1607 4.1x1 ~3

-/-/-/1 b

-/-/-/1

-/-/-/1 3

7/74 0/0/0/87 4.1x10'4

-/-/-/14 b

-/-/-/8

-/-/-/8 11/75 1601/0/0/0 6.8x10 4 1/-/-/-

b 1/-/-/-

1/-/-/-

11/75 162/0/0/158 6.8x10~2 8/-/-/24 b

5/-/-/8 5/-/-/8 5/76 1595/0/0/1590 2.3x10~

1/-/-/1 b

1/-/-/1 1/-/-/1 7/77 0/1619/1609/0 0

-/16/19/-

b

-/5/10/-

-/5/10/-

2/-/-/-

2/s/-/-

11/78 1594/0/0/0 0

2/-/-/-

b' 15/-/-/13 15/-/-/13 11/78 1594/0/0/1589, 9.7x10'2 17/-/-/26 b

06/81 0/634/0/0

)-

0

-/10/-/-

b

-/2/-/-

-/2/-/-

TOTAL 71/27/30/94 43/8/21/43 43 /8/21/43 or or or 4.41/1.71/1.9%/5.7%

2.71/0.51/1.31/2.7%

2.71/0.51/1.31/2.7%

ll[JPi NOTES:

Yankee has never sleeved or pulled any tubes.

I r mary / Secondary leakage rates are the total for all 4 steam generators.

I p Yankee has stainless steel tubes.

t J Testing and identification of leaking tubes is not broken down into hot and cold legs.

Type of Degradation This inforination is not available, a-W:.s tage b-Cracking Type of Degradation c-IGA a-Wastage d Ditting b-Cracking e-Fatigue c-IGA f-Erosion / Corrosion d-Pitting g-Denting e-Fatigue f-Erosion /Corroston g-Denting g

SAN ON0FRE UNIT 1 STEAM GENERATOR TUBE LICENSING ACTIONS Date M

07/18/74 Letter transmitting Regulatory Guide 1.83 and requesting proposed change to the Technical Specifications (TS).

04/01/77 Amendment No. 25 to license requires steam generator to be reinspected within 12 months from the date of the amendment.

10/06/77 Order r quiring that the licensee submit information needed to ' confirm the rate of growth of steam generator tube degradation in the vicinity of the old anti-vibration bars.

12/20/77 Amendment No. 29 pertains to eddy current test on steam. generator tube degradation and requires steam generator inspections.

1 03/24/78 Amendment No. 32 clarifies when the twelve-month s/

inspections of steam generators must be made, which is in reference.to Amendment No. 25.

04/20/78 Amendment No. 34 acknowledges that the results of the steam generator denting inspection program satisfy license requirements and, therefore, approved resumption of power operation, in reference to Amendment Nos. 25 and 32.

10/31/82 Amendment No. 37 acknowledges that inspection results indicate that the steam generator tube denting and support plate cracking have been connected.

We, therefore, found performance of subsequent steam generator inspections in accordance with ISI, TS 4.16 acceptable.

06/08/81 Amendment No. 55 approves steam generator tube sleeving.

v.

-~--

-m-.

--sm--

-,n-,,

w w--

-- - - - --,- +--

I e

I SAN ONOFRE I W I s

f 8

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY No. Defects Primary to i

No. Tubes Secondary Type of Regselring No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reoafr Pluqqed/ Sleeved / Pulled j

i S.G. Musber A/B/C Hot A/8/C Cold A/8/C A

B C

1 j

Factory i

1 10/70 0.01 8 S/G

-/-/-

4/-/-

-/-/-

02/72

-/-/677 0.33 C S/G

-/-/I

-/-/l

-/-/- -/-/-

1/-/-

4 j

01/72

-/920/-

-/98/-

-/0/-

-/0/-

-/-/- 0/0/0

-/-/-

I 07/72

-/-/818 0.07 C S/G

-/-/9

-/-/9

-/-/- -/-/-

9/-/-

01/73 0.066 A S/G 1/-/-

1/-/-

1/-/-

-/-/-

-/-/-

06/73 2700/1273/721 1156/544/351 4/5/6 h

2/5/6 4/0/2 5/-/-

6/-/-

03/75 788/721/900 891/1408/344 4/2/12 h

1/2/6 -

4/-/-

2/-/-

12/-/-

-/-/-

-/-/-

1/-/-

06/75

-/-/-

-/-/-

1/-/-

01/16 10/76 1397/1050/590 385/0/0 34/18/51 h

22/13/41 34/-/-

18/-/-

51/-/-

09/77 2550/2550/2480 0/0/0 10/19/12 8/11/12 10/-/-

19/-/3 12/-/-

7/-/-

-/-/-

8/-/-

10/73 42/-/75 4/74 71/-/-

0.028 S/G 4/-/-

J/-/-

1/-/-

l 4/78 697/0/746

-/-/-

7/-/7 g,a 7/-/7 7/-/-

-/-/-

7/-/-

4 9/78 630/685/523 458/226/226 24/9/25-

-/-/1

-/-/-

-/-/-

1/-/-

1 (Gen.Insp.)

9/78 671/683/548

-/-/-

h

-/-/3

-/-/-

-/-/-

3/-/-

(AVB) 9/78 314/44/432 18/-/31 g

-/1/1

-/-/-

1/-/-

1/-/-

(Denting) 6/79 639/0/215

-/-/-

0/07 A S/G 21/-/-

a-21/-/ -

21/-/-

-/-/-

-/-/-

4/80 3699/3744/3670 1998/652/360 0.180 S/G 178/141/178 a h,g,other 143/60/20 143/-/3 60/-/- 20/-/-

6/80 2315/2145/2787 104/-/-

658/466/718 c/a 655/466/718 102/2244/7 185/2141/-

169/

TOTALS 941/660/1019 860/558/825 339/2244/12 294/2141/3 321/2141/9 or %

or or or or 8.5 24.81/17.41/26.9%

22.71/14.21/21.8% 8.9%

7.8%

Type of Degradation a-Wastage e-Fatigue b-Cracking f-Erosion / Corrosion c-IGA g-Denting d-Pitting h-Wear against anti-vibration bar (AVB) i

(

HADDAM NECK I

STEAM GENERATOR TUBE LICENSING ACTIONS Date Typ.e 10/21/77 Amendment No. 20 revised Tech Specs to specify LCO's for Operability of Steam Generators and reactor coolant system leakage through steam generators; and to add surveillance requirements for steam generator tube inservice inspection program.

1 l

l

HADDAM NECF STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY Primary to No. Defects No. Tubes secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reoair Plugged / Sleeved / Pulled S.G. Nunber A/B/C/D Hot A/B/C/D Cold A/B/C/D_

A/B/C/D A

B C

D 1970 0/0/0/115 0/0/0/0 0/0/0/2 b/a 0/0/0/2 0/0/0 0/0/0 0/0/0 0/0/2 1971 HYDROSTATIC TESTS 1/2/0/0 a

1/2/0/0 1/0/02/0/0 0/0/0 0/0/0 1972 0/0/1569/0 0/0/0/0 0/0/14/0 a

0/0/14/0 0/0/00/0/014/0/0 0/0/0 1

1973 1495/1605/892/1630 0/0/0/270 0/0/0/10 a

0/0/0/10 0/0/0 0/0/0 0/0/0 10/0/0 1975 1220/1026/400/450 669/165/165/345 0/0/0/8 a

0/0/0/8 0/0/0 0/0/0 0/0/0 8/0/0 1976 977/1059/698/779 0/0/0/0 1/1/0/2 a

1/1/0/2 1/0/01/0/0 0/0/0 2/0/0 1977 1211/1161/357/689 0/0/0/0 1/0/1/0 a

1/0/1/0 1/0/00/0/0 1/0/0 0/0/0 1979 246/221/149/178 0/0/0/0 0/1/0/0 a

0/1/0/0 0/0/0 1/0/0 0/0/0 0/0/0 1980 637/712/0/0 623/810/0/0 0/2/0/0.

a 0/2/0/0 0/0/0 2/0/0 0/0/0 0/0/0

- 5/18/ 2/ 0-a S/18/ 2/ 0 I 5/0/018/0/02/0/0 0/0/0

.1981 1370/1333/781/ 717 0/ 0/ 0/ 0 10 Gal'/Diy (3 sg)

TOTAL 8/24/17/22 8/24/17/22 8/0/0 24/0/0 17/0/0 20/0/2 or or or or or or

.2%/ 6%/.5%/.6%

.21/.6%/.5%/.6%

0.2%

0.6%

0.5%

0.61 Type of Degradation a-Wastage b-Cracking c-IGA d-P1tting e-Fatigue f-Eros 1on/Corros1on g-Denting e

a.

e

GINNA STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 4/8/81 Letter in regard to request for sleeving changes to Ginna ISI Program submitted by letter dated 11/16/80.

12/30/ 80 Letter approving reque'st for withholding proprietary information submitted by letter dated 11/6/80.

7/8/80 Letter. enclosing NRC staff evaluation of results of 4/80 S/G inspection at Ginna.

6/13/80 Amendment No. 33 - Secondary water chemistry monitoring.

7/23/79 Letter in regard to secondary water chemistry parameters.

1/30/79 Amendment No. 23 - Sampling frequency for secondary coolant.

)

8/9/78 Letter in regard to steam generator conference (mass mailed).

5/17/77 Amendment NO. 13 - Put S/G inspection requirements in ISI Program vice Technical Specifications.

5/14/75 Amendment No. 7.- Reduced allowable S/G tube leak rate from 1.0 gpm to 0.1 gpm.

,..-.__.-,,.---,--,.--r

_r,.,_,

,,-.w,._,

,,.-,.--v,

.,.7

I GINNA STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY Primary to No. Defects No. Tubes Secondary Type of Requiring.

No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reoair Plugged / Sleeved / Pulled S.G. Ntaber A/B Hot A/B Cold A]B

,A/B A

B 1/-

1/-/-

-/-/-

In Factory 1/-

4/72 1050/-

-/-

0/0 0/0 0/-/-

0/-/-

3/74 3259/1098 516/516 19/0 a

19/0 19/-/2 0/-/-

11/74 1707/672 430/39 2/0 a

2/0 2/-/-

0/-/-

3/75 2174/1931 442/442 0.0050 A S/G 46/11 b/a 46/11 46/-/2 11/-/-

1/76

-/53

-/-

0.091 B S/G 0/2 a

0/2 0/-/-

2/-/-

i 2/76 3192/3247 3192/3247 39/2 a

39/2 39/-/-

2/-/-

4/76 100/1025

-/75 0.099 B S/G 0/15 b

0/15 0/-/-

15/-/-

13/1 a

13/1 13/-/-

1/-/-

4/77 2003/1525 268/26B 7/77

-/300

-/-

0.012 B S/G

-/5 b

-/5

-/-/-

5/-/-

1/78

-/350

-/-

0.060 B S/G

-/8 b

-/8

-/-/-

8/-/-

4/78 2049/1714 325/375 1/15 b

1/15 1/-/-

14/-/1 2/79 2049/1714 325/375

-/6 b,a.c

-/6

-/-/-

6/-/-

12/79

-/1200

-/-

0.007 B S/G

-/13 c,a

-/13

-/-/-

13/-/-

4/d0 3139/3182 325/375 1/31 d/c 1/13 1/-/-

28/-/3 11/80 3139/3151 325/375

-/3 c

-/2

-/-/-

0/5/-

5/81 3138/3141 325/400

-/15 ca

-/6

-/-/-

1/16/3 TOTAL 122/127 122/99 122/-/4 106/21/7 or or or or 3.71/3.9%

3.71/31

.3.71 3.5%

i Type of Degradation a-Wastage b-Cracking c-IGA d-Pi tting c-Fatigue f-Erosion / Corrosion g

g-Denting I

4

k

~

s ROBINSON STEAM GENERATOR TUBE LICENSING ACTIONS Date

_ Type 11/17/79 Amendment 44 re Revising ISI Program, T.S. 4.25 10/22/80 Letter from CP&L comitting to-interim inspection 08/28/81 Amendment 60 re License condition requiring inspections and setting leakage limits 11/13/81 Amendment 61 re Modification of license condition requiriiig conditions l

RGlINSON i

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY V

No. Defects

'i Primary to Type ofU)

Requiring (1)

No. Tubes No. Tubes Secondary OI Degrad.

Reoatr Plugged / Sleeved / Pull (d g

[

Date Inspected' Leakage, age Total Defects c

j S.G. Number A/B/C Hot A/B/C Cold A/B/C A/B/C A/B/C A/B/C A

B C

l e

6/71 92/0/0 -/-/- 92/0/0 5/72 2270/340/1200 27/0/3 4/0/0 2/0/0 11/75 146/-/410

-/-/4.18 0/0/0 -/-/-

1/0/0 l

6/74*

3179/-/3260 9/0/0 22/0/2 7/0/0 4/75 763/1320/871 1/0/0 10/0/0 -/-/-

11/75*

736/646/796 391/47/287 2/0/0 3/0/0 11/0/0 1

11/76 1511/1588/2239 553/524/871 7/0/0 5/0/0 -/-/-

3/7d**

1851/1714/3121 793/861/3119 10/0/- 3/0/0 6/0/0 9/73 MONE NOME 0.62 /-/-

2/0/0 -/-/-

-/-/-

4/79**

2085/1946/3110 1927/1753/3116

-/0.28 /-

8/0/0 21/0/0 10/0/0 3/83 3150/-/-

0.15/-/0,15 40/0/0 0/0/0 17/0/0 l

4/d0 3150/-/-

-/0.5 /-

27/0/0 86/0/0 30/0/0 7/80 10/-/-

1/-/-

1/0/0 -/-/- -/-/-

9/80 N0 INFORMATION 38/0/2 54/0/0 15/0/0 7/81 227/-/-

TOTAL OF 0.30 36/0/0 113/0/0 34/0/0 11/dl 9/-/-

TOTAL OF 1.5 38/-/- 133/0/0 47/0/0 TOTALS 338/0/5 454/0/2 272/0/0 or or or 10%

12%

11%

  • Multiple eddy-current inspections with varying frequencies for cracks & sludge.
    • Used largest number of inspections for denting or defects.

Couplete Data not available k

\\

POINT BEACH l' STEAM GENERATOR TUBE LICENSING ACTIONS Date

.Tyjte 11/30/79 Order for Modification of License - set increased frequency for steam generator tests and inspections, more restrictive primary to secondary leakage limits, more restrictive reactor coolant radio-activity' levels and surveillance frequency.

1/30/80 Order for. Modification of License - set reactor coolant system operating pressure limit of 2000 psig.

4/4/80 Order for Modification of License - revised S/G testing and inspection frequency of 11/30/79 Order.

8/8/80 Letter '- concurred in proposed S/G inspection interval.

02/13/81 Letter - concurred in proposed S/G inspection interval.

11/10/81 Amendment 56 - S/G tube sleeving.

12/30/81 Letter - recommended mid-cycle S/G inspection interval.

POINT BEACH 2 j

10/30/81 Amendment 47 - secondary water chemistry monitoring program.

l l

l f

l I

3 1

POINT SEACH 1 STEAN GENERATOR TISE INSPECTION AND PLUGGING HISTORY l

Primary to No. Defects No. Tubes Secondary Type of Requiring No. Tubes ***

Date Inspected Leakage, ops Total Defects **

Degrad.

Repair Plugged / Sleeved / Pulled 5.G. Number.

A/B Mot A/B 0,old A,

B_

.AJ_

A B

A 8

l.

Il 7/--

--/ =/--

i In Factory l

2/73 1598/887 0/0 84 84 a,b/a,b 84 84 101/--/--

92/--/3 4/74 1317/1023 365/0 1

1 a,b/a,b 1

1 1/--/--

1/--/--

2/75 3137/3129 121/55 125.0 B S/G 54 93 a,b/a,b 54 93 59/--/--

98/--/--

1 11/75 976/1419 184/0 6

4 a,b/a,b 6

4 6/--/--

4/--/--

10/76 899/587 454/0 0

0 0

0 0/--/--

0/--/--

6/77

-/-

-/-

0 1

a/a 0

1 0/--/--

1/--/--

4 10/77 597/491 275/105 11 2

c g/c 11 2

11/--/--

2/--/--

2/78

-/-

-/-

090 A S/G 1

0 1

0 1/--/--

0/--/--

3 1

0 1/--/--

0/--/--

5/78

-/-

-/-

101 A S/G 1

0 9/78 1683/1771 169/0 7

4 i s,b/a,b 7

4 7/--/--

4/--/--

i 3/19 8/0 0/0

.156 A S/G 8

1

c.9/c 8

1 8/--/--

1/--/--

8/79 2944/2862 104/0 1.45 A S/G 52 45 c/c 52 45 52/--/--

45/--/--

8/79

-/-

-/-

.225 A S/G 2

0 c/c 2

0 5/--/--

0/--/--

12/79 3009/3009 L/0 70 64

'a c/a.c' 70 64 75/--/-2

.68/--/--

12/79 961/862 0/0

.174 B S/G 19 15 c/c ~

19 15 20/--/--

15/--/--

i 2/80 1103/767 167/141

.021 24 32

'c/a.c 24 32 24/--/--

36/--/--

t 7/80 2748/2899 109/153 014 28 22 c/c 28 22 31/--/--

22/--/--

11/80 2855/2853 165/126

.003 3

7

'c/INf!

3 7

3/--/--

7/--/--

7/81 2814/2816 0/0-003 2

3 c/c 2

3 2/--/--

3/--/--

10/81*

2766/2792 97/97 007 9

7 c/c 9

7 9/12/--

7/--/--

TOTAL 382 385 382 or 11.75 412*/12/2 or 385 or 11.8%

or 406/0/3 5 tubes previously plugged were recovered by sleeving jy.%

l 11.81 12.6%

or tube defect is defined as >50% degradation 12.55 4

      • tube plugging Ilmit is >401 degradation TmMWMM a-Wastage f-Erosion / Corrosion Type of Degradation j

a-Wastage f-Erosion / Corrosion b-Cracking g-Denting c-IGA b-Cracking g-Denting d-Pitting c-IGA e-Fatigue l

d-Pitting e-Fatigue i

i t

4

i I'

POINT BEACH 2

  • I ll:

STEAM GENERATOR TtBE INSPECTION AND PLUGGING HISTORY Primary to No. Defacts No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ops Total Defects

  • Degrad.

Repair Plugged / Sleeved / Pulled 5.G. Number A/B Hot A/B Cold A_

B_

Ag A,

B_

A-B 1/- 1/--7--

In Factory 3/73

-/-

-/-

0 0

0 0

0/--/--

0/--/--

10/74 1090/442 475/114 3

4 a,b/a,b 3

4 3/--/--

4 /-- /--

l 8/75 0/722 0/10 0.35 8 S/G 0

3 a,b/a,b 0

3 0/--/ u 3/--/--

2/76 1223/1120 600/1996 14 4

a,b/a,b 14 4

14/--/--

4/--/--

i 3/77 1056/1457 221/670 2

5 g/a,b 2

5 2/--/--

5/--/--

l l'

3/78 1335/796 505/1069 2

0 a,b/a,b 2

0 2/--/---

0/--/--

3/79 400/364 19/230 0

1 s,b/a,b 0

1 0/--/--

1/--/--

2/80 3138/717 149/685

.986 A S/G 35 1

a,b/a,b 35 1

35/--/--

1/--/--

25 16 a,b.c/a,b 25 16 25/--/1 16/--/--

i 4/81 3185/2269 0/470 i

TOTAL 81 34 81 34 82/--/-1 35/--/--

i i

er or or or or or i

2.5%

1.1 %

2.5%

1.11 -

2.5%

1.1%

l Type of Degradation a-Wastage b-Cracking c-IGA d-Pi tting e-Fatigue Cracking f-Erosion / Corrosion g-Denting

' Defect is defined as an imperfection that exceeds the minimum acceptable tube thickness of 50%.

6 e

SURRY UNITS 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS (for old steam generators)

Date Type,e*

Surry 1:

2/8/77 Order 2/11/77 Order 5/6/77 Order 9/6/77 Prenotice for 25% plugging 10/21/77 Prenotice for SG Replacement 12/3/77 Order 6/23/78 Order 1/15/79 Prenotice for 28% plugging 12/2/77 Amendment for 25% plugging 12/29/78 Amendment 1/19/.79 Amendment for SG Replacement 2/5/80 Amendment (Corrected 3/19/80) 7/28/80 Amendment O.

5/9/79 Amendment fnr ? M ningging Surry 2:

4/1/77 Order 8/17/77 Order 9/6/77 Prenotice for 25% plugging 10/8/77 Order 10/21/77 Prenotice for SG Replacement 4/7/78 Order 4/28/78 Order cor'recting FQ for plugging 12/2/77 Amendment for 25% plugging 8/16/78 Amendment 1/19/79 Amendment for SG Replacement The Orders and amendments in this column which do not have explanatory words were issued to require inspections of the steam gene'rators at intervals not to exceed 6 months. These frequent inspections were intended to provide for safe operation for the severely derraded (dented) stean generators.

1 1

l

~

SURRY UNIT e

'I STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY (Note 3)

Ni. Defects Primary to No. Tubes secondary Type of Requiring No. Tubes Date Inspected' Leakage, ape Total Defects Degrad.

Reosir Plugged / Sleeved / Pulled S.G. Number NOTE 2 NOTE 1 1A/18/1C(Note 1) 1A IB IC

{

12/74 g

55/0/0 2/0/0 84/0/0 10/75 g

242/0/0 6/0/0 115/0/0 3/76 g

24/0/0 66/0/0 42/0/0 l

7/76 g

1/0/0 2/0/0 24/0/0 12/76 g

206/0/0 246/0/0 272/0/0 i

4/77 g

1/3/0 89/0/0 168/0/0 155/0/0 11/77 a/g TOTAL 228 (NOTE 4) 5/78 a/g 20/0/0 31/0/0 53/0/0 i'

12/78 0.3 a

75/0/0 60/0/0 114/0/0 I

a 5/0/0 1/0/0 20/0/0 5/79

.005 a

11/0/0 18/0/0 25/0/0 4/80 8/80 0.3 a/g 0/0/0 0/0/0 36/0/0 E

TOTALS 1/3/0 884/0/0 676/0/0 1016/0/0 or or or or 0.031/0.091/01 26.2% 20.01 30.01 HOTE 1: The principal concern with these tubes was denting and hourglassing. For that reason,~ through-wall or partial through-wall

~

wastage was considered to be a negligible concern.

NOTE 2: This information was not available.

WOTE 3: In 1980, and 1981, all steam generators were replaced. 1005 inspection was conducted on the replacement tubes with no recorded defects.

NOTE 4: Breakdown not available. Assumed appmminately one third per S.G. for totals below.

Jype of Degradation a-Wastage e-Fatigue b-Cracking f-Erosion / Corrosion c-IGA g-Denting d-Pitting SS

\\

l

i

~

SURRY UNIT F j

',t, g

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY (NOTE 3) i b

No'. Defects Primer.v to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reoatr Plugged /Steeved/ Pulled

[

f NOTE 1 NOTE 1 2A 28 2C S.G. Number NOTE 2 g

5/0/0 8/0/0 0/0/0 4/14 0/0/0 0/0/0 6/0/0 g

7/74 10/0/0 19/0/0 10/0/0 g

9/74 35/0/0 29/0/0 68/0/0 g

l 5/75 0/0/0 0/0/0 159/0/0 g

s 1/76 5/76 g

104/0/0 102/0/0 21/0/0 g

157/0/0 151/0/0 103/0/0 10/76 276/0/1 247/0/1 196/0/0 g

2/77 TOTAL 180(NOTE 4) 7/77 0.3 g

9/77 0.16 g

TOTAL 198 (NOTE 4) 11/77 421 0.3 g

g 4/78 31/0/0 19/0/0 20/0/0 a

7/78 744/0/1 701/0/1 709/0/0 TOTAL or or or 21.2%

20.7% 21.0%

4 NOTE 1: The principal concern with these tubes was denting and hourglassing. For that reason, through-wall or partial through-wall wastage was considered to be a negligible concern.

NOTE 2: This infonnation was not available.

Preservice inspection was conducted on 100% of the tubes NOTE 3: All Steam Generators were replaced during 1979 replacement outage.

with no recorded defects.

NOTE 4: Breakdown not available. Asstaned approximately one third per S/G for totals below.

Type of Oeoradation a-Wastage b-Cracking c-JGA d-Pitting i

e-Fatigue f-Erosion / Corrosion g-Denting r

1 4

1 TURKEY POINT 3 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 1/14/78 License Amendment permitted startup and required SG inspection in six months.

7/15/77 License Amendment permitted startup and required SG inspection in six months.

8/16/77

. License Amendment permitted startup and required SG inspection in ten months.

1 / 31 /78 License ~ Amendment permitted startup and required SG inspection in six months.

6/02/78 License Anendment permitted startup and required SG inspection in two months.

10/16/78 License Amendment permitted startup and required SG inspection in four months.

i 3/ 30/79 License Amendment permitted startup and required SG inspection in six months.

I 9/26/79 License Amendment permitted startup and required SG inspection in seven months.

1/25/80 License Amendment permitted startup and required SG inspection in six months.

7/ 30 / 80 License Amendment permitted startup and required l

SG inspection in 2.5 nonths.

i 10/30/80 License Amendment permitted startup and required SG inspection in six months.

4/17/81 Letter permitted startup and required SG inspection in six months.

6/23/81 License Amendment permitted startup and required SG inspection in six months.

6/24/81 License Amendment to permit replacement.

l I

TURKEY POINT

-3 STEAN GENERATOR TUBE INSPECTION AND PLUGGING HISTORY Primary to No. Defects No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reoatr Plugged / Sleeved / Pulled *

[

S.G. Nun 6er A/B/C Cold M

A/B/C A/B/C A/B/C (1972 Factory Insp_A]B/C Hot _

ection) g272793 10/74 1455/1289/836 52/662/50 N/A 21/7/6 a/a/a 21/7/6 21/7/6 b

12/75 N/A 23/4/9 a/a/a 23/4/9 23/4/9 2/76 N/A

-/2/-

-/b/-

-/2/-

-/4/-

3/76 N/A

-/2/-

-/b/-

-/2/-

-/2/-

6/76 0.0316 1/-/l b/-/-

1/-/1 1/-/1 8/76 0.11 1/-/-

b/-/-

1/-/-

1/-/-

12/76 N/A 76/59/58*

b/b/b 76/59/58 68/151/58 12/77 0/0467 181/263/158 8/78 0.009 1/-/1 b/-/b 1/-/1 1/-/1 2/79 1562/1433/1574 486/488/694 0

19/5/9 c/c/c 19/5/9 186/159/225 1/80 1726/1223/1283 315/437/690 N/A 0/2/5

-/c/c 0/2/5 67/46/67 10/80 1325/1541/1533 713/252/381 N/A 13/0/1 c/-/c 13/0/1 70/7/23 3/81 1501/1412/1440 486/349/586 N/A 10/23/25 b/b/b 10/23/25 10/23/28 TOTALS 165/104/115 165/104/115 721/668/669 or or or 5.2%/3.3%/3.5%

5.21/3.3%/3.5%

22.51/20.91/20.9%

Type of Degradation a-Wastage b-Cracking c-IGA d.Pltting e-Fatigue f-Erosion /Corros1on 9 " 9

  • No tubes were sleeved or pulled.

&S

i 1

INDIAN POINT 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 12/8/76 Amendment No. 23 established S/G tube inspection program.

5/31/77 Amendment No. 30 changed the S/G inspection orogram.

7/11/77 Amendment No. 31 established provisions of S/G tube inspection program.

5/12/78 Amendment No. 40 established limits on primary to secondary leakage via the S/G's.

9/7/79 Amendment No~. 58 authorizing operation for up to 16 months before next inspection of all S/G's.

4/22/81 Amendment No. 69 allowing operation with up to 12% S/G tubes plugged.

4

INDIAM P0lNi T STEAM CENERATOR TUBE INSPECTION AND PLUGGING HISTORY No. Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes i,

Date Inspected teakage, ope

. Total Defects **

Degrad.

Renalr Plugged / Sleeved / Pulled S.G. Nunt>er 21/22/23/24 21/22/23/24 21/22/23/24 21/22/23/24 21/22/23/24 21 22 23 24 g

I 93/0/0 95/0/0 94/0/0 102/0/0 '

In Factory

/-/

0/1/0/0 0/0/0 9/0/0 0/0/0 0/0/C

-/g/-/-

3/75 165/456/456/275 0/<0.1/0/0 0/9/0/0

-/-

0/0/0/0 0/0/0 0/0/0 0/0/0 0/0/0 6/76 372/279/0/0 0/0/0/0 0/0/0/0 11/76 0/0/194/154 0/0/0/3 0/0/0/3

-/-/-/g 0/0/0/3 0/0/0 0/0/0 0/0/0 6/0/0 4/77 360/363/0;9 0/0/0/0 8/3/0/0 g/g/-/-

0/0/0/0 0/0/0 0/0/0 0/0/0 0/0/0 3/18 0/0/463/471 0/0/0/0 0/0/47/70

-/-/g/g 0/0/2/6 0/0/0 0/0/0 ~15/0/9 S/0/0 '

7/79 430/375/272/?96 0/0.06/C/0 112/76/68/107 g/g/g/g 3/9/6/5 3/C/0 1U 0/0 6/0/0 6/0/0 '

12/80 404/391/433/395 0/)/('/0.

42/95/131/iC3-g/g/g/g 1/8/2/5 1/0/0 8/J/0 2/0/0 5/0/0 4/81*

107/105/169/95 0/0/0/0 2/6/11/3 g/g/g/g 0/US/0 0/0/0 I/0/0 5/0/0 0/0/0 8/ l*

O/0/9/0 n/3/<u.1/0 0/0/1/0

-/-/3/-

Of-/1/1 0/S/c 0/0/0 4/0/0 0/0/0 101A1.

214/189/22d/288' 4/I9/16/20 97/0/0 124/0/0126/0/9,125/CfD or or.

or or or

'or

-6.565/5,795/6.995/8.13f.

0.1%IO.6%/0.51/0.6% 2.97% 3.8%

3.86% 3.83%

HOTES: *All inspections are hot leg except a/31 (it is the only cold leg inspecClon).

    • This column contains some repetitive defects in subsequent inspections. Dented tubes which will not pass a size 0.700 inch probe are included in this column.

However, by definition they are not defectin tubes. Sey are simply tubes of concern. A degraded tube is one which has g nater than 20% thinning of the wall from its original dimensions. A defective tube has > 40% of the, tube wall thickness removed. A dented tube which will not pass a 07610 inch probe Wil generally be plugged.

bl Type of Degradation a-Wastage b-Cracking c-IGA d-Pi tting e-Fatigue f-Erosion / Corrosion 9-Denting

k s

TURKEY POINT 4 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type _

12/03/76 Order permitted operation and required inspection after 60 days.

2/08/77 Order permitted operation.and required inspection after 120 days.

5/03/77 Order permitted operation and required inspection after 120 days.

8/03/77 Order permitted operation and required inspection after six months.

2/10/78 Order permitted operation and required inspection after six weeks.

3/08/78 Order permitted operation and required inspection after six months.

9/22/78 License Amendment permitted operation and required

)

inspection after six months.

3/23/79 License Amendment permitted operation and required inspection after ten days.

6/15/79 License Amendment permitted operation and required inspection after six months.

2/14/79 License Amendment permitted operation and required

' inspection after two months.

2/22/80 License Amendment permitted operation and required inspection after four weeks.

3/21/80 License Amendment permitted operation and required inspection after four weeks.

6/12/80 License Amendment permitted operation and required inspection after six months.

1/15/81 License Amendment permitted operation and required inspection after six mortNs.

6/23/81 License Amendment updatcA iscense conditions.

6/24/81 License Amendment t; te af

  • replacment.

7/06/81 License Amendment keraltti. operation and required inspection after two months.

9/10/81 License Amendment permitted operation and required inspection after two months.

I o

i l

m i

TURKEY POINT b li 4 t

STEAM GENERATOR TUBE INSFECTION ANO l' LUGGING HISTORY l-No. Def'ects Primar,v to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reaalr Plugyd/ Sleeved / Pulled S.G. Number A/B/C Hot A/B/C Cold A/B/C A/B/C A/B/C A/B/C.

A/B/C*

33/42/8 a/a/a 33/42/8 33/42/8 8/74 2024/2142/2104 453/24/38 64/67/ %

a/a/a 64/67/96 64/67/96 5/75 3747/3191/2829 8/75

-/1/-

-/b/-

-/1/ _

-/2/-

-/1/-

9/75 0.0783

-/1/-

-/b/-

-/1/-

-/11/-

-/1/-

1/76 0.0031

-/-/1

-/-/b

-/-/1

-/-/2 5/76 9/76 0.65

-/16/2

-/b/b

-/16/2 98/151/105 15/16/1 1/77 0.145

-/-/3

-/-/b

-/-/3

-/-/3 3/77 0.26

-/-/2

-/-/b

-/-/2

-/-/2 4/77 0.256

-/1/4

-/b/b

-/1/4 133/305/169 6/77

-/-/1

-/-/l 11/77 0.345

-/1/-

-/b/-

-/1/-

-/8/-

0.347 1/1/-

b/b/-

1/1/-

167/80/109 2/78 g

86/28/61 9/78 4/79 1440/1355/1441 739/357/395 6/-/-

c /-/-

6/0/0 79/52/54 5/80 1506/1479/1355 530/364/454 8/3/3 c/c/c.

8/3/3 72/48/56 10/80 1581/2013/1592 471/644/701 3/18/4 c/c/c 3/10/4 27/57/48 10/81 1688/1506/1559 718/517/696 4/0/7 c/-/c 4/0/7 35/41/28 TOTAL 119/151/130 119/151/130 794/892/740 15/18/2 or or or 3.75/4.71/4.1%

3.71/4.71/4.1%

24.81/28.01/23.1%

h il Type of Degradation I

a-Wastage b-Cracking c-IGA d-Pitting

{

e-Fitigue f-Erosion / Corrosion

  • Tubes pulled. None were sleeved, g-Denting 1

i,

(

1 ZION 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Tyge 2/06/78 Amendment 34 and 31 for Zion 1 and 2

'respectively to add surveillance requirements for SG tubes and leak rates 4/28/80 Amendment 54 and 51 for Zion 1 and 2

'respectively to add secondary water chemistry program 4/07/ 81 Amendment 64 and 59 for Zion 1 and 2 respectively to clarify reporting requirements on inspections O

l l

1 i

l l

(

l

^

ZION 1 AND 2 ~

T-STEAM GENERATOR TUBE INSPECTION AND PLUGGINr. HISTORY No'.. Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes i

Date Inspected Leakage. que Total Defects Degrad.

Reoair Pluqqed/ Sleeved / Pulled l

A/B/C/D A/B/C/D 5.G. Number HOT COLD A 8 C 0 A/B/C/D

.A_ 8 C. O A

B C

D I

i~

g/-/-/-

0 l

3/76 476/-/-/-

0 9

36 g/-/-/g 0 - - 0 9/77 872/-/-/439 0

25 j

+

0 0 0 0 i

2/75 1621/635/566/603

  • 0 0 0 0 0

- 0 O

- 0 9/78

-/603/-/-

31GPD 8 SG 0 22 7 0

-/a/N-0 20 5 0

-/-/- 20/-/- 5/-/- -/-/-

I 1/81 186/2567/2541/188 N 27 7 T6 YN T -

-/-/- 20/ / ~ 5/-/- -/-/-

or or or or or or or or or or 4

l'0051.65'.

211 1.0651

.591.1481

.6%

.141 ZION 2 s

- - - 0 65

-/-/-/g 1/77

-/-/-/467 0

l 1/76 1733/589/589/589 0,

0 0 0 37

-/-/-/g

- - - 0 0

0

- 0 O

0 3/78

-/1332/-/1125 0

0 3/79

-/-/-/407 0

10/-/-

3/-/-

9/81 1910/-/1888/-

O 19 3 -

a/-/a/.

10 3

19 3 102 10 3

10/-/-

3/-/-

or or or or or, or or 0.561.0881 3.031

.301.0881

.3%

.081

  • No distribution between Ibt or Cold. ECT runs the whole tube
    • Wastage was major defect. Crack or hole in at least one tube.

Types of Deseadation i

a-Wastage c-!GA e-Fa tigue

. g-Denting I

b2 Cracking d-Pitting f-Eroston/ Corrosion 1

l r.

PRAIRIE ISLAND UNITS 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 7/18/75 Anendment No. 7/7 - Placed a limit on SG tube leakage not to exceed 1.0GPM 8/25/78 Amendment No. 31/25 - Placed revised

[i surveillance requirements on S.G tubes (I

10/22/79 Meeting Minutes of meeting held 10/12/79 -

Meeting to determine requirements for continuted operation after 10/2/79 SG tube rupture unit 1 3/20/80 Meeting Minutes of meeting held 2/12/80 -

Review Unit 2 SG January 1980 inspection

(

o i

l PRAIRIE ISLANG' calT 1 1:

l STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY No. Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes i

Date Inspected

  • Leakage. goe Total Defects Degrad.

Reoatr Plugged / Sleeved / Pulled S.G. Number afb Hot A/B Cold A

8 A

8 A_

B, f

I

.f.f.

_f_f.

74 548/1132 49/468

_f_f.

_f'f_

l 75 142/166 81/82

_f.f.

_f f, 4

76 272/275 139/144

.f.f.

.f.f.

I 77 262/255 177/80

_f,f,

,j,f, 78

---/439

-/.

6/-/-

-/-/-

y 2

1 79 555/516 18/6 390 A SG 2

1

-/./.

If f.

-l 80 316/481 628/540

.3 8 SG 1

z 81 515/381 3372/1112 10 0

d/f 10 0

25/-/-

2/-/-

TOTALS 12 I

12 I

31/-/-

3/-/-

0.35%

0.02951 0.351 0.0295 0.911 0.0881 Types of Degradation a-Wastage b-Cracking d-Fretting f-Cctr:: tan x-Incorrect plug location

,y-Mechanical damage z-Tubesheet damage r

i 1

m t

,g PRAIRIE ISLAND UNIT 2 STEAM GENERATOR TUBE INSPECTION AND PLUGGINR HISTORY 6,

No'. Defects Primary to l

No. Tubes Secondary Type of Requiring No. Tubes i

Date Inspected

  • Leakage, ope Total Defects Degrad.

Reosir Plugged / Sleeved / Pulled i

S.G. Number A/B Hot A/B Cold A

8 A

B_

A_

8 l!

-/-/-

-/-/-

74 3385/3390 3388/3388

-/-/-

-/-/-

1/8/76 141/147 72/72

-/-/-

-/-/.

11/9/76 142/134 65/67 1

-/-/-

1/-/-

77

-/779

-/-

0.3 B SG I

b 1

4 f

1 4

3/-/-

15/-/-

80 489/566 754/1404 i ~ !

3/8/81 287/274 1285/3351 2

20 d,f 2

20 4/-/-

38/-/-

1

-/-/-

-/-/-

1 x

9/9/81

-/9

-/-

0.3 B SG TOTALS

. 3 26 3

26 7/-/-

54/-/-

i I

0.0881 0.771

.0881 0.771

.2071 1,61 i

Types of Degradation a-Wastage b-Cracking d-Fretting f-Corrosion x-Incorrect plug location y-Nechanical damage z-Tube:heet damage 4

d

(

2 KEWAUNEE STEAM GENERATOR TUBE LICENSING ACTIONS Date

Type, 1/31/78 Amendment No.18 to the Technical Specifications requires a repair inspection of the tubes on a sampling boron, and a category action of the reaneting degradation, if any.

Inspection frequencies, tube plugging, and reporting requirement are also established.

C>

l l

4W"

)

e' i[

~

g;.

V l

-i KEWAUNEE NUCLEAR POWER PLANT 1

STEAN GEIERATOR TISE INSPECTION AND PLUGGING HISTORY 8

s No. Defects Primary to No. Tubes Secondary Type of Requirfag No. Tubes l

)j Date Inspected Leakage, ops Total Defects Degrad.

Repair Plugged / Sleeved / Pulled S.G. Number A/B Hot A/B Cold 2/76

' 1505/781 769/-

None 2*

g None None None gg, 1/77 1090/523 468/468 Mone None g,

5/80 323/602 319/-

None i

2 t

  • Two defects were identified as manufacturing defects, or 0.06%

I.

Type of Degradation g

a;lWastage l

b'l Cracking 1

cl IGA I

d i Pitting e l Fatigue / Cracking 1

f i Errosion/ Corrosion j

ghDenting i

8 I

Ii 4

I, l

J 1

i j

l 1

+

i J

i COOK 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 2/29/80 Secondary water chemistry monitoring program e

4 s

i i

4 e

i l

1 l

l. -.-...

g.-

^

t I

COOK 1

  • 1 i

STEAN GENERATOR TUBE INSPECTION AND PLUGGING HISTORY i

Primary to No. Defects No. Tubes

  • Secondary IAI Type of Requiring No. Tubes Total Defects Degrad.

Reoair

      • Plugged / Sleeved / Pulled Date Inspected-(B)

Leakage, apm S.G. Nurd>er 1/2/3/4 1/2/3/4 1/2/3/4 1/2/3/4 1/2/3/4 1/2/3/4 In Factory 0/0/0/1 4/76 728/776/1336/1390 NONE NONE NOME NONE 6/78

-/1222/1222/-

NOME NONE NONE NONE 2/77

-/-/1290/1290 NONE NONE MONE MONE 4

5/19

-/-/235/-

NONE NONE NONE NONE 7/80

-/-/707/-

NONE NONE NONE NONE 7/81 701/-/-/696 NONE NONE NONE 10*/0/0/10*

TOTAL 10/0/0/11 or 0.3%/01/01/0.3%

COOK 2 In Factory 0/10/t9/0 12/79

-/835/892/-

NONE NONE '

NONE 0/10*/10*/0 10/80 327/-/-/-

1/0/0/0 a/0/0/0 -

NONE 5'+1/0/0/0 4/81 795/w/-/709 NONE

'NONE NONE 4*/0/0/10*

10/81 0/-/-/-

1/0/0/0 a/0/0/0 NONE 1+2.**/0/0/0 TOTAL 2/0/0/0 13/20/20/10 or or 0.06%

0.3%/0.61/0.6%/0.3%

  • These tubes p1'ugged as preventive measure in vicinity of the tube lane blocking devices.
    • Plugged based on leak test at inspection - no cause determined.

f Degradation

      • Tubes plugged only - no sleeving or pulling.

,,g C

"9 NOTE A: In all cases except in factory. 4 measurable, but very small. leakaae existed.

well below the T/S Ilmit.

d-Pittin NOTE B: Data was not broken down between hot and cold legs, e-Fatigu i

f-Erosion /Eorrosion g-Denting 1

e4

(

TROJAN STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 10/22/79 Letter re:

Provide causes of leaking tubes -

S/G A&D and basis for resuming operation.

5/22/80 Letter re:~ Removal of row 1&2 tubes from U S/G for examination.

5/19/81 Letter.re: Agreeing to PGE's plans to plug all row 1 tubes in S/G "B" & "C"

)

i f

l

n i.

g.

m STEAM GENERATOR TUBE IllSPECTION AND PLUGGING HISTORY 3

Primary to No. Defects No. Tubes secondary Tyne of Requiring No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reosir Plugged / Sleeved / Pulled j

f S.G. Number A/B/C/D Hot A/B/C/D Cold A/B/C/D A/B/C/D A

B C'

D t-4/75 (Pre 3300/3300/

3300/3300/

0/0/0/0 0/0/0/0 0/0/0 0/0/0 0/0/0 0/0/0 l

i Service) 3300/3300 3300/3300 0/-/0/-

0/0/0 0/0/0 0/0/0 0/0/0 i

5/77 664/0/1323/0 664/0/1323/0 0-0/-/0/-

1 3/78 0/603/0/0 0/603/0/0 0007 B SG

-/1/-/-

b

-/1/-/-

0/0/0 1/0/0 0/0/0 0/0/0 10/79 94/93/94/94 94/93/94/94

.08 A,D SG 1/0/0/4 b

1/0/0/4 2/0/0 1/0/0 1/0/0 5/0/0 6/80 94/94/94/238 94/94/94/238

.,05 A,3,C.D SG 3/2/0/0 b

3/2/0/0 4/0/0 3/0/0 1/0/0 2/0/29.

I 1/dl 0/0/0/0 0/0/0/0

. 25 A.B.C.D SG 1/-/-/3 b

1/-/-/3 88/0/0 0/0/0 0/0/0 58/0/0 l

5/81 0/0/0/0 0/0/0/0 07 B,C SC

-/9/18/-

b

-/9/18/a'-

0/0/0 89/0/0 92/0/0 0/0/0 i

TOTALS 5/12/18/7 5/12/18/7 94/0/0 94/0/0 94/0/0 65/0/29 or or or or or or I

0.11/0.4%/0.55/0.2%

0.11/0.45/0,55/0.2%

2.8%

2.8%

2.8%

1.9%

J v

Type of Degradation 4-Wastage b-Cracking l

c-IGA I-d-Pitting e-Fatigue f-Erosion / Corrosion g-Denting a

eee aw 1

r

(

INDIAN POINT 3 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type.

'8/02/78 SER approving'UT Inspection of S/G head cladding.

6/27/80 License Amendment No. 31 requires a midcycle inspection of one S/G and end of cycle inspection.

of all S/G.

11/20/80 SER concerning midcycle S/G inspection.

1/15/81 License Amendment No. 34 establishes date of next S/G inspection.

11/13/81 License Amendment No. 40 allows operation with up to 12% of S/G tubes plugged.

11/13/81 License Amendment No. 41 temporarily modified the definition of a degraded tube until March 1982.

4

(

3 Fg

^

INDIAN POIN Y STEAM GENERATOR TIBE INSPECTION AND PLUGGING HISTORY No. Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ape Total Defects.

Degrad.

Reoalr Pluqqed/ Sleeved / Pulled S. G. Number 31/32/33/34 Hot 31/32/33/34 Cold 31/32/33/34 31/32/33/34 31/32/33/34 31/32/33/32 31 32 33 34 i

7/78

-/-/292/292

-/-/0/0

-/-/0/0

-/-/-/-

-/-/0/0

-/-/- -/-/-

0 1/0/0 8/78 15/-/-/-

0/-/-/-

3/-/-/-

h/-/-/-

1/-/-/-

3/0/0 -/-/- -/-/-

O l

12/78

-/-/28/-

-/-/0.24/-

-/-/1/-

-/-/g/-

-/-/1/0

-/-/- -/-/-

1/0/0 -/-/-

3/79

-/-/-/30

-/-/-/0.145

-/-/-/1

-/-/-/g

-/-/-/1 4/0/0 4/0/0 3/0/0 4/0/0 9/30

-/800/-/-

-/-/-/-

-/448/-/-

, g/g/g/g 1/0/1/1 97/0/0 111/0/0 113/0/0 114/0/0 9/79 488/537/682/498 -/501/685/-

-/-/-/-

254/74/294/243

-/-/- 9/0/0 -/-/- -/-/-

-/g/-/-

-/0/-/-

5 10/81 231/-/-/-

3156/3136/3143/3141 0.77/0/0/0 577/448/489/320 d/d/d/d

    • 176/69/47/37** 181/0/4 74/0/0 49/0/0 63/0/0 TOTAL 834/970/784/564 178/69/49/39 285/0/4 198/0/0 166/0/0 182/0/0 or or or or or or

'25.61/29.81/245/17.3%

5.51/2.1!/1.51/1.21 8.8%

6%

5.1%

5.58%

NOTES: *This column contains some repetative defects in subsequent tr.spections. Dented tubes which will not pass a size 0.700 inch probe are included. However by definition they are not defective tubes.

they are sluply tubes of concern. A degraded tube is one which has 3J0% thinning of the wall from its original dimensions. A defective tube has 3,40% wall thinning. A dented tube which will not pass a 0.54 inch probe will be plugged.

    • Technical Specifications were temporarily modified to allow operation until March 1982 If they were not modtfled a total of 286/208/154/114 tubes for S/G 31/32/33/34 respectively would have required plugging.

Type of Degradation a-Wastage i i b-Cracking 1

I c-IGA d-Pitting e-Fatigue f-Erosion / Corrosion i

g-Denting h-Tube damaged by a welder while installing I

t

) k i

O 4

I g

b I

('

BEAVER VALLEY l STEAM GENERATOR TUBE LICENSING ACTIONS Date

Type, 1/30/76 Original License.

Establishs inspection program with surveillance requirements and criteria.

7/09/76 License Amendment No. 6.

Changes to TS relative to secondary water chemistry total cation conductivity.

2/29/80 License. Amendment No. 26. Adds license condition requiring.a secondary water chemistry monitoring program and deletes TS for the monitoring program.

l 0

1

(

^

O o

i BEAVER VAL cr1 f

STEAM GENERATOR TUBE INSPECTION AND PLUGGINR HISTORY I'.

I No! Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reoat r Pluqqed/ Sleeved / Pulled S.G. Number A/B/C Hot A/B/C Cold A/B/C A/B/C A/B/C A

B C

j

,f 9/75 3388/3388/3388 3388/3388/3388 0/0/0

-/-/-

0/0/0 0/0/0 0/0/0 0/0/0 9/78 182/153/0

-/-/-

1/1/-

g/g/-

0/0/0 0/0/0 0/0/0 0/0/0

-/-/0

-/-/-

0/0/0 0/0/0 0/0/0 0/0/0 j,

3/80 0/0/122 0/0/195 i

TOTALS 1/1/0 0/0/0 0/0/0 0/0/0 0/0/0 i

or t

g

.02951/.02951/0 Type of Degradation a-Was tage l

b-Cracking i

c-IGA 1

d-Pitting l

O-Fatigue f-Erosion / Corrosion 1

g-Denting 1

4 1

4

SALEM UNITS 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type _

Salem 1 8/13/76 Technical Specifications requiring periodic S/G inspections ~ to meet R.G. 1.83 Salem 2 5/30/81 Technical Specifications requiring periodic S/G inspections to meet R.G. 1.83

+

s C/

(

l

-T-f

'e

=

y ori ev-'ey t--

wwr-'*w== ' - - " '

"wmwww

-w-yweam--Nw--+--'--**r--'--v-

,etw w

-'er+-*----'n~

r-NTw-N" ' "

- * - - - = = -'=u'*

l

^

r.:

I I

4 SALEM INil ~.#

l' l'

!(!:

STEAM GEIERATOR TUBE IIISPECTION AllD PLUGSING HISTORY p

a Primary to lis.' Defects No. Tubes Secondary Type of Requiring 10o. Tubes ll Dete Inspected Leakage,ess Total Defects Degrad.

Reoalr' Plugged / Sleeved / Pulled l

S.G. Number A/8/C/D Hot A/8/C/D Co1d A/8/C/D A/8/C/D A/8/C/D A/8/C/D A

B C-D l

]

7/79*

10/368/10/288 10/76/10/10 10/0/10/10 a/-/a/a.g 10/0/10/10 10/-/- 0/-/0 10/-/ 10/-/-

-/-/- -/-/-

I 9/80

-/-/617/-

-/-/329/-

10/80 454/-/-/-

268/-/-/-

-/-/- -/-/-

i

-/3/-/8

-/a,q/-/a.o

-/3/-/8

-/-/- 5/-/- -/-/- 18/-/-

1/82 "

-/539/-/160

-/448/-/1543 TOTAL 10/3/10/18 10/3/10/18 10/0/0 5/0/0 10/0/0 28/0/0

,i or or or or or or l

.31/.11/.31/.5%

.31/.11/.31/.51

.3%

.151

.3%

.831 t

)

I l

  • lST for S/G #12 and 14 as well as special inspection for all S/Gs after modification with tube lane blocking devices.
    • Cerrent inspection not coupleted.

(Sales Unit 2 has had no steam generator inspection).

Types of Degradation e

a-Wastage b-Cracking c-IGA d-Pitting C-Fatigue f-Eroston/ Corrosion i

1 g-Denting i

i 1

I i

1 1

I i

l 1

l

(

FARLEY 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date M

6/25/77 Unit 1 License was issued with Standard Technical Specifications including the augmented inservice inspection program for SG tubes.

2/13/79 Unit 14 License Amendment No. 8 was issued adding a license condition requiring a secondary water chemistry monitoring program to inhibit steam generator tube degradation. The amendment also required record keeping for secondary water sampling and water quality.

3/31/81 Unit 2 License was issued with Standard Technical Specifications including the augmented inservice inspection program, requirements for the secondary I

water chemistry program and record keeoing.

i i

l l

E e

)

8, FARLEY b '

1, j

STEAM GENERATOR TUBE INSPECTION AND PLUGGINR HISTORY a

l' i

No. Defects l

Primary to No. Tubes Secondary Type of Requiring No. Tubes l

j i

Date Inspecte#

Leakage, ape Total Defects Degrad.

Reoatr Plugged / Sleeved / Pulled S. G. Number A/B/C A/B/C M

A/B/C A

B*

C 3

l Factory Note (1)

N/A 0/0/0

-/-/-

-/-/-

-/-/-

-/-/- -/-/-

Pre Service 3388/3388/3388 N/A 0/0/0

-/-/-

0/0/0

-/-/- -/-/- -/-/-

3/ 79 366/0/567 0.00625 C SG 0/-/]

-/-/ Note (2) 0/0/1

-/-/- -/-/-

1/-/-

l 6/80 0/87/0 0.0792 B SG

-/3/-

-/ Note (3)/-

0/3/0

-/-/-

3/-/-

-/-/-

i 12/80 ISI 0/50 7/0 0.0784 C SG

-/0/1

-/-/ Note (2) 0/0/1

-/-/- -/-/-

1/-/-

j i

9/81

-/-/-

0.00347 8 SG

-/2/1

-/ Note (2)/ Note (2) O/2/1

-/-/-

2/-/-

1/-/-

0.00694 C SG 12/81

-/-/-

N/A

-/-/-

Note (4)

-/-/-

94/-/- 89/-/- 91/-/-

l TOTALS 0/5/3 0/5/3 94/0/0 94/0/0 94/0/0 I

or or or or or I

-/0,151/0.091

-/0.151/.091 2.8%

2.81-2.8%

NOTE:

Factory inspection records not retrie'ved at this time.

During plant startup leakage detected by pressure testing. Characterization of type of leakage not required to be determined.

L Tse identified as leaker by visual inspection during pressure test. Eddy current testing of other tubes provided signals that I

could not be characterized, therefore tubes plugged.

j (4) All SG row I tubes plugged as a result of history of previous leakers and not being able to evaluate row I U-bend cracking problems.

)

Types of Degradation a-Wastage b-Cracking j

c-IGA 1

d-Pitting e-Fatigue f-Erosion / Corrosion g-Denting

  • Data was not broken down between hot and cold legs.

l 1

0

l

^

F4ILEY 2 g.

i STEAM GEE NATON itBC INSPECTION AND PLUGGING NISTONY v.

.l 1

No. Defects No. Tubes Secondary Type of Nequiring No. Tubes l'

J Primerv to 3

Date Inspected

  • Leakage age Total Defects Degrad.

Nepair Pluonnd/ Sleeved / Pulled g

i S.G. Number A/8/C A/8/C A/B/C A/8/C A

B C

t i

j i

Factory Note (1)

N/A 1/1/0 Note (1)/ Note (1)/-

1/1/0 1/0/0 1/0/0 -/-/-

Pre Service 3387/3387/3388 N/A 0/0/0

-/-/-

0/0/0

-/-/- -/-/- -/-/-

1 8/80

-/-/-

N/A 2/-/-

Note (2)/-/-

2/0/0 2/-/-

-/-/- -/-/-

}

6/81

-/-/-

0.00694A 1/-/-

Note (3)/-/-

1/0/0 1/0/0 -/-/- -/-/-

l I

TOTALS 4/1/10 4/1/0 4/0/0 1/0/0 0/0/0

?-

or or or or or O.121/.031/0 0.121/.031/0

.121 031 0

1? Factory inspection records not retrieved at this time. Factory plugged. reason not retrieved at this time.

2 NOTE
I j

? During installation of SG handioles, two tubes were accidentally nicked. Tubes plugged, L

i ll3J During plant startup. leakage detected by pressure testing. Characterization of type of leakage not required j

to be determined by Tech. Spec.

k t

i, l

Type of Degradation a-Wastage b-Cracking c-IGA l

d-Pitting e-Fatigue j

f-Erosion / Corrosion g-Denting

]

  • Data was not broken doun between hot and cold legs.

I i

l l

t i

1 2

i

) -

i i

NORTH ANNA UNITS 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS UNIT 1 Date Type.

2/4/80 NRC letter (Safety Evaluation regarding istSGinserviceinspection) 4/8/80 NRC letter (Information Request regarding SG secondary chemistry) 11/21/80 NRC letter (Safety Evaluation regarding SGsecondarychemistry)

UNIT 2 April 1980 SER/ Supplement 10 to NUREG-0053 (Secondary Water Chemistry and SG Tube Integrity)

April 11,1980 Fuel Load License / Condition (Secondary Water Chemistry)

August 21, 1980 Full Power License / Condition (Installation of SGinspectionports) i 1

I

(

\\

l l

l t

^'

n NORTH ANNA V STEAM GENERATOR TU8E INSPECTION AND PLUGGINr. HISTORY

.l l

5 No. Defects Prfaery to No. Tubes Secondary Type of Nequiring No. Tubes J

I thte Inspected

  • Leakage, age Total Defects Degrad.

Iteoatr Plugged / Sleeved / Pulled j

S.G. Nunber IA/18/1C Hot A/8/C A/8/C 1A 18 IC Preservice Steam G nerator inspection was conducted with eddy current technique. 100% of the tubes were inspected and zero defects were recorded.

2.08 x 10~3 132/19/155 g

0/0/2 94/0/0 94/0/0 96/0/0*

9/79 440/340/480 94 94 96 132/19/155 or or or 3.91/0.61/4.6%

2.8%

2.8%

2.8%

or l

  • All row I tubes plugged prior to startup after the first refueling

.l outage. In addition SG,1C had 2 additional defective tubesplugged.

i

    • Ligament cracking indication only.

)

NORTH ANNA 2 94/0/0 94/0/0 94/0/ 0*

Prfor to startup 0/0/0 94 94 94 I

or or or f

2.8%

2.8%

2.8%

j 1

l

' All row 1 tubes plugged prior to obtaining a low power and full power license. Low povr Itcense (4/11/80) and full power license I

(8/21/80).

I Types of Degradation i

c-Wastage b-Cracking l

c-IGA d-Pitting 0-Fatigue a

f-Erosion / Corrosion j

g-Denting i

4 i

l 4

i

a.

g.

(

SEQUOYAH 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type 9/80 Unit 1 OL - included SG inspection per R.G. 1.83 l

9/81 Unit 2 OL - included SG inspection per R.G. 1.83 I

s i

i i

l

!(


,-,,......,,-__-.,.n

.,-.-.--.n.,

-. _ _ -.,,,,..., -. _. - - -, - -, -,,,,, - -, -,.,. ~..., -. -

~

r b

l t

SEQUOfAH UNIT 1 g

l STEAM GEERATOR 1UBE IIISPECTION AND PLUGGIIIG HISTORY

[

i No. Defects Primary to No. Tees

' Secondary Type of P:9J1 ring leo. Tubes Date Inspected leakage, ape.

Total Defects Degrad.

Roosir Plugged / Sleeved / Pulled S.G. ilumber 1/2/3/4 Hot 1/2/3/4 Cold 12/77 3388/3388/3188/3388 0

0 0

Manu. U-Bend 0

0 (Bulge) j j

9/d1 12/12/12/323 12/12/12/372 0

0 U-Bend Fretting O'

0

& Denting t

SEQUOYAH UNIT 2 i

j j

2/78 3388/3388/3388/3388 0

0 0

U-Bend 0

0 l

6/31 94/94/94/94 0

0 0

U-Bend 0

0 I

i i

1

.9 4

4

(

i MCGUIRE UNIT 1 STEAM GENERATOR TUBE LICENSING ACTIONS Date

Tyoe, 3/78 SER-NUREG-0422 sunnarizes staff evaluation of S/G tube integrity relating to control of secondary water chemistry and inservice inspection.

1/81 SER Supplement No. 4 (NUREG-0422) summarizes further staff. evaluation of S/G tube integrity relating to secondary water chemistry, row one S/G tube cracking suspectability and steam generator inspection tests.

01/7/82 Letter, NRC to Duke Power requests licensee to provide update information from November 20, 1981 briefing meeting.

1/19/82 Letter, NRC to Duke Power; approve interim operation with Model D S/G notifies licensee that staff approves interim operation of McGuire Unit 1 with Model D S/G.

(

}

^

l IEGUIRE cr. -

g i

STEAft GENERATOR TUBE IIISPECTION AND PLUGGIIIR HISTORY

(

Primarv to llo. Defects Ito. Tubes Secon'dary Tyne of Requiring 100. Tubes

('

i Date Insracted Leakage ese Total Defects Degrad.

Reoair Plugged / Sleeved / Pulled g.

i S.G. Ilumber A/B/C/D Hot A/B/C/D Cold A/B/C/D A/B/C/D A

B C

D f

I In Factory 4674*/-/-/-

4674*/-/-/-

0 0/0/0/0 0/0/0/0 Preservice 4674 per SG 4674 per SG 0

0/0/0/0 0

0/0/0/0 3

1/80 0

0 0

0/0/0/0 0

0/0/0/0 1/81 0/0/0/0 172/0/0/0 0

0/0/0/0 0

0/0/0/0 20/0/0 ** 20/0/ 0*'20/0/0 ** 20 /0/0**

1/81 0/0/0/0 172/0/0/0 0

0/0/0/0 0

0/0/0/0 TOTALS 20/0/0 20/0/0 20/0/0 20/0Al or Or or or 0.4%

0.41 0.4%

0.4%

t

  • Eddy current conducted of tubes prior to bending a installation in S/G.
    • Tubes plugged to accomodate codification; no defects.

i:

l 1

t'

's i

t-4 I

1 l

l e

l 4

1

(

1 DIABLO CANYON UNIT 1 STEAM GENERATOR TUBE LICENSING ACTIONS Date M

6/80 SER Supplement No. 9 Section 5.2.7 discusses secondary water chemistry, inspection ports and Row 1 tubes.

S 9

/

v

... -,. ~,,....-.

- =.... -..

p

?

DIMILO CANYON W II 1 STEAM GUENATWt TISE INSPECTION AND PLUGGilIR HISTORY 4

l Primary to No. Defects No. Tubes Secondary Type of Nequiring No. Tubes f

Date Inspected Leakage, eps Total Defects Degrad.

Neoatr Plugged / Sleeved / Pulled l

i l

S.G. Nud er A/B/C/D Hot A/8/C/D Cold A/8/C/D A/p/C/D

_A/B/C/D 4

j l

In Factory Not Available Pre-service All Tubes All Tubes 0

0/0/0/0 0

0/0/0/0 0/0/3/0.

j

+

1 6

i i

o 9

?

i t

I p.

e t,f, tab l

1 OPERATING EXPERIENCE WITH C0feUSTION ENGINEERING pWR STEAM GENERATORS THNOUGH JANUARY 1982 i-l l

Prev.

Other Corr.

e SG OL Secondary Exp.

Induced Wall Secondary No. of No. (1)

Model Issu.

water chen, w/P0 Thinning or side Init.

Leaking of Tubes Sleeve

~

Plant Name No.

Date control Contki Wastage Pitting SCC Denting (b)

Tubes Plugged Repairs Palisades (a) 3/71 AVT Ves X

X X

X-Moderate 3748(221)

I-33 tube j

g )

15(11)

Maine Yankee 9/72 AVT No X-Minor 0

Ft. Calhoun 5/73 AVT No X

0 3(<11)

Calvert I

CIlffs 1(d) 8/74 AVT No.

X-Ninor 0*

5(<11) j Millstone 2 E/75 AVT No X-Extensive 0

1509(91)

St. Lucie 1 3/76 AYf No X

X-Minor 1

130(<'s)

Calvert i

Cliffs 2(d) 8/76 AVT No X-Minor 0

5(<11) l Arkansas 2(d) 9/78 AVT No X-Minor 0

21(<11)

(a) CE steam genarators do not have specific model numbers. For the plants listed above, the steam generators are of the same basic design with the exception of Palisades. Palisades employs drilled hole support plates for the lower six tube supports instead of egg crate supports.

(b) Denting is described as extensive, moderate, or minor as follows:

extensive denting - (a) presence of tube denting that is widespread throughout whole steam generator in which the average total reduction in tube diameter equals to or exceeds twice the tute wall thickness; (b) measurable support plate in-plane deformations, such as hour 11assing of flow slots in Westinghouse plants; (c) damage has caused leaking from dents.

moderate denting - (a) presence of tube denting that is widespread throughout whole steam generator in 'which the average total reduction in tube diameter exceeds 20% of the tube wall thickness; (b) no measurable support plate in-plane deformation; (c) damage has g caused leaking l

from dents.

l minor denting - (a) presence of tube denting is spotty to widespread,*but the average total reduction in tube diameter is less than 20% of the tube wall thickness; (b) no visible support plate deformation; (c) damage has n$tt caused leaking from dents.

I (c) Tubes plugged because they are used to structurally support the support plate - not due to any degradation.

(d) Tubes were plugged free the factory.

.09 gallons per hour e

1 I

e

PALISADES PLANT STEAM GENERATOR TUBE LICENSING ACTIONS Date hpe.

08/10/73 Letter regarding steam generator B primary to secondary leak.

~

?

08/30/74 Ainendment 10 to License.

Interim Authority to conduct 60%

~

power operations necessary for removal of chemical inpurities in steam generator.

11/27/74 Amendment 11 to License. Remove power restriction and issue Technical Specifications for steam generator limiting conditions for operation and surveillance requirements.

02/06/75 Order to Consumers Power Company requiring Palisades to remain in cold shutdown and perform additiona.1 steam generator inspections and get approval of results from NRC prior to restart.

03/28/75 Amendment 13 to License granted authority to return to operation to a maximum power level of 2100 Mwt, approved inspection ~results and plugging,~ and instituted an aupnented surveillance require-

)

ment for steam generator.

09/25/75 Amendment 15 to License changed interval to next steam generator.

inspection from 90 effective full power days to 135 effective full power days and reinstated R. G. 1.83 inspection criteria.

' mendment 20 to U cense revises Steam Generator plugging 04/26/76 limits, removes flushing. requirements for steam generator, revises inspection interval for steam generator.

06/17/77 Amendment 28 to License extends the steam generator inspection interval for 5 months.

01/09/78 Amendment 33 to License institutes a revised augmented inspection program for the steam generator.

04/07/78 Amendment 39 to the License changes operating allowances and inspection requirements for the steam generator.

01/19/79 Notice in Federal Register of licensee's request to replace steam generators.

04/10/79 ASLB's " Order Scheduling Special Prehearing Conference" for steam generator replacement.

(

07/23/79 Special Prehearing Conference Order establishing Hearing and issue Notice of Hearing.

11/05/81 Letter stating NRC acceptance of the 1981 steam generator inspection results and corrective measures at Palisades.

PALISADES i

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY J

No. Defects 3

,i Primary to No. Tubes Secondary Type of Requiring No. T Date Inspected *'

Leakage, ape Total Defects Degrad. -

Reoair Pluqqed/ Sleeved / Pulled j

S.G. Number A/B lbt A/8 Cold M

A B*

01/73 1114/929

-/-

.3A S/G 657/656 a

657/656 653/-/4 656/-/-

09/73 6572/6553 1182/73S

.58 S/G 290/49 a

290/49 290/-/-

49/-/-

07/74 7461/7662 6800/436 42 S/GE 797/234 a,c,d 797/234 791/-/ 6 234/-/-

f 03/75 6745/7500 836/352 79/202 a,c 79/202 79/-/-

202/-/-

4 03/76 6686/7377 507/513 103/603 a c.dE I

103/603 103/-/-

603/-/,

i 02/78 1846/1436 110/75 14/10 aN 14/10 9/18/-

7/10/-

10/79 1877/1472 466/432 14/9 a.g 14/9 14/-/-

9/-/-

10/81 2415/1878 495/476 9/40 a,g 9/40 9/-/-

40 - -

1907TB03 1 % 3/1803 1948/18/10 1

/

or or or or 231 21.2%

231 21.21 22.91/.2%/.1% 21.11/.11/0 MinorDentingObserved Nound During Hydro Test 3 dotal number of tubes sleeved is 28 for both steam generators:

2 tubes in A have 2 sleeves 3 tubes in 8 have 2 sleeves Type of Degradation a-Wastage I

c-IGA d-Pitt6ng g-Denting 1

l

(

MAINE YANKEE STEAM GENERATOR TUBE LICENSING ACTIONS Date

.Tr e,

5/10/77 Amendment 28 - Approval of revised Technical Specification 4.10 - added steam generator inspection provisions.

1/30/78 Letter 50.54(f) - Milestone Unit 2 tube support plate found cracked -- determine if this problem exists at Maine Yankee.

Justify continued operation.

8/7/78 Letter - Discusses April 11, 1978 meeting on proposed modifications to steam generator. - Licensee must justify safe operation during Cycle 4.

If SG inspections determine modifications required -

submit modifications for NRC review.

t

(

l

=

MAINE VANKEY i

l STEAM GENERATOR TUBE INSPECTION AND PLUGG1 t. M13 TORY No'. Defects Primary to No. Tubes Secondary Type of Requiring

~No. Tubes l

Date Inspected' Leakage, ops **

' Total Defects Degrad.***

Reoafr Plugged / Sleeved / Pulled l

l S.G. Number 1/2/3 Hot 1/2/3 Cold 1/2/3 1/2/3 1

2 3

3 6/74 190/190/0 60/60/0 0

0 0/0/0 0/0/0 0/0/0 0/0/0 0/0/0 i

5/77 221/230/0 221/230/0 0

0 g/g/g 0/0/0 0/0/0 0/0/0 0/0/0 6/78 474/536/536 474/536/536 0

0 g/g/g 0/0/0 5/5/0* 5/5/0 5/5/0 2/80 0/0/628 0/0/628 0

0 g/g/g 0/0/0 0/0/0 0/0/0 0/0/0 5/81

  • 0/ 51 6/ 0 0/ 51 6/ 0 0

0_

g/g/g 0/0/0 0/0/0 0/0/0 _ 0/0/0 0

0/0/0 5/5/0 5/5/0 5/5/0 i

or or or 1

11 11 1%

  • Tubes plugged following staking as part of a support plate rim cut modification. The tubes were not degraded. See MYAPCO letter to USNRC dated August 10,1978. WMY-78-75.
    • Maine Yankee has had no primary to secondar leakage to date.

occurring on either side of a tube. Denting does not fall into these categories.

s Type of Degradatie a-Wastage

+

b-Cracking c-IGA d-Pitting e-Fatigue f-Eroston/ Corrosion g-Denting 1

I i

1 a

i FORT CALHOUN UNIT 1 STEAM GENERATOR TtBE LICENSING ACTIONS Date Tyge 5/73 OL issued 7/79 Amendment 46 issued - established surveillance requirements for S/G tubes

)

i a

I' i

..---.-.x...-.,..-,-,.4

s i

1 FORT CALHOUN'VillT 1 1:j STEAN GENERATOR TUBE INSPECTION AND PLUGGING HISTORY f

No'. Defects

!i j

Primary to No. Tubes Secondary Type of Requirfnq No. Tubes l

Date Inspected Leakage. ope

  • Total Defects
  • Degrad.

Reoair Plugged / Sleeved / Pulled g

S.G. Number A/B Hot A/B Cold gg NB A

B 0/0 0/0/0 0/0/0 0/0 1/73 200/200 0/0 2/75 225/226 0/0 0/0 0/0 0/0/0 0/0/0 i

0/0 0/0/0 0/0/0 10/76 0/408 0/0 0/0 0/0 0/0 0/0/0 0/0/0 10/77 150/0 0/0 0/0 a

0/0 3/0/0 0/0/0 10/78 493/0 0/0 0/0 0/0 0/0/0 0/0/0

[

11/dl 0/328 0/0 l

TOTALS 3/0/0 0/0/0 or

.g

.05

  • A defect is defined in the Appendix A T5s to mean an imperfection of such severity that it exceeds the plugging Ilmit.

Type of Degradation a-Wastage b-Cracking c-IGA d-Pitting e-Fatigue f-Erosion / Corrosion g-Denting I

C t

I s

CALVERT CLIFFS 1 AND 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date M

. 8/13/76 Unit 2 OL - included S.G. inspection per R.G. 1.83

^

~ Unit 1 Amsndment 50 - S.G. inspection 4/26/77

. per R.G. 1.83 O

e i

____-_,_..,,c,_

_,m

_,,,,_,-,._,,,y

n l**

.a CALVERT CLIFFS UNIT 1 e

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY 8

No'. Defects Primerv to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reoafr Plugged / Sleeved / Pulled S.G. Number A/B Hot A/B Cold NB NB A

B*

8

-/-

3/0/0 2/0/0

-/-

In Factory 0/0 0/0 l

1/77 175/175

-/-

0/0 A

0/0 3/78 350/10

-/-

0/0 0/0 j

1/79 0/350

-/-

0/0 l

10/u0 350/0

-/-

0/0 I

i 3

2 TOTALS or or 0.041

.021

  • Leakage af ter last inspection indicates recent leak of.090 GPH i

40 m

n m

CALVERT CLIFFS w lT 2 1

STEAM GENERATOR TUBE INSPECTION AND PLUGGINR HISTORY u

I No. Defects Primer.v to i

No. Tubes Secondary Tyoe of Requiring No. Tubes l

Date Inspected Leakage, ape Total Defects Degrad.

Reoafr Pluqqed/ Sleeved / Pulled i

t i

S.G. Nud er A/B Hot A/B Cold

_A[B M

A B

-/-

-/-

3/0/0 2/0/0 In Factory 9/78 179/175

-/-

0/0 0/0 9/19 350/0

-/.

0/0 0/0 1/81 0/582

-/-

0/0 0/0 TOTALS 3

2 or or 0.04%

0.02%

I e

(

i MILLSTONE 2 STEAM GENERATOR TUBE LICENSING ACTIONS Date

Type, 4/14/78 Amendment 37 - SG tube denting and support plate modification, added special SG surveillance requirements.

5/12/79 Amendment 52 - Cycle 3 operation with reduced SG surveillance requirements.

10/5/80 Amendment 61 - Cycle 4 operation, reports SG tube and support plate inspections.

2/18/82 Amendment 72 - allows less than 100% ECT inspection based 'on results of special tests.

2/ /82 Cycle 5 amendment with SG inspection results, 704 tubes' plugged.

O 1

(

l

i.J b

il 1

. s L

~

NILLSTONE UNIT 2 6-g STEAN GEIERATOR TWE INSPECTION AND PLUGGING HISTORY,

Primary to Ilo. Defects No. Tubes Secondary Type of Requiring No. Tubes

. Date Inspected Leakage, ope Total Defects Degrad.

Repair Plugged /Sieeved/ Pulled S.G. Number A/B Hot A/B Cold A/8 A/8 A/8 A/B A

8 V

l 5/77

'272/349 0/0

-/-

0/0 0/0 0/0/0 0/0/0 1

1/78 2475/2947 29 % /2728

-/-

0/0 g

0/0

  • 361/0/0 *439/0/0 i

e 4/79 2927/2261 514/261

-/-

0/0 g

0/0 0/0/0 0/0/0 9/80 1228/875 0/0

-/-

0/0 g

0/1 0/0/0 1/0/0

?

I 12/81 7201/6828 6982/6582

.11/.06 691/381 d

427/ 284 424/0/3 284/0/0 i

f l

TOTAL 691/381' 427/284 785/0/3 724/0/0 or or or or j

8.11/4.5%

5.01/3.31 9.2%

8.5%

  • NNECO perfonned a rim-cut in 1979.

l Total number of tubes 8519/SG l

CE Nodel U-tube generator Nos. A-67510; 8-67511 Type of Degradation a-Wastage b-Cracking

)

c-IGA I

d-P1tting i

c e-Fatigue j

f-Erosion / Corrosion l

4 g-Denting l

1 1

(..

s ST. LUCIE 1 STEAM GENERATOR TUBE LICENSING ACTIONS Date lY.P.e.

11/16/81 Amendment #47 - Permits operation with inspection of less than all tubes - Problem area limited to tubes;.with U-bends.

4 l

l l

(

..)

^

,_ s ST. LUCIE 1 Il

.I STEAN GENERATOR TUBE INSPECTION AllD PLUGGING HISTORY

's l'

i I

No. Defects i

Primary to l

No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reoalr Plugged / Sleeved / Pulled k.

-.B A

B

(

S.G. Number A/B Hot A/B Cold A

B i

5--

-5 In Factory 0

0 0

0 5/75 (Baseline).

' UNKNGfN 0

0 00 0

0 0

4/7d 604/0 100/0 0

0 0/0/0 0 0/0 0

0 11/78 697/540 0/0 0

0 9/0/0 13/0/0 0

0 5/79*

894/900 0/0 0

,.0.

0/0/0 0/9/0 0

0 4/80-735/827 0/0 10/81 2282/3228 0/0 3.7x10"5 30 46-f-

30 46 57/0/0

.d6/0/0 TOTALS 30 46

- 30

.46 71/0/0 59/0/0 35%

541

.351 54%

,84%

.691 1'

  • CE Support Plant Nodification.

Types of Degradation a-Wastage b-Cracking c-lGA d-Pitting e-Fatigue f-Erosion / Corrosion g-Denting a.

9

^

r OPERATING EXPERIENCE WITH BABC0CK AND WILC0X ONCE-THROUGH JTEAM GENERATORS THROUGH JANUARY 1982 1

OL No. of No. (%)

Plant Name Issuance Startup Fatigue Erosion /

Leaking of Tubes 31eeves i

(Notes 1 and 2)

Date Date Cracking Corrosion Tubes Plugged Installed Oconee 1 2/73 5/73 X

X 9

313(2%)

Oconee 2 10/73 12/73 X

X 3

30(<l%)

Oconee 3 7/74 9/74 X

X 5

103(<1%)

4 Arkansas 1 5/74 6/74

?

X 3

18(<1%)

Rancho Seco 1 8/74 8/74 X

X 1

15(<1%)

Three Mile Island 1*

10/74 10/74 X

i Crystal River 3 1/77 1/77 X

0 33(<1%)

Davis Besse 1 4/77 8/77 X

2 27(<1%)

Three Mile Island 2 2/78 (NRC suspended authority to ooeration) 38(<1%)'

j (b) BW steam generators do not have specific model numbers, but are of the same basic design.

a)

)

L BW plants have been operated exclusively with AVT secondary water chemistry control, t

4 0 At least 130 leaking tubes from nitrogen bubble tests; complete inspection in progress. Major SG problem discovered l

11/81; potentially several thousand tubes affected. No tubes repaired yet.

~

1 l

4 l

's

f L

f

/

ff) h tu d k

2 OCONEE UNITS 1, 2 AND 3 STEAM GENERATOR TUBE LICENSING ACTIONS Date

_ Type 10/4/77 Amendments 47, 47 and 44 re leakage limits for SG tubes.

02/22/80 Amendments 80, 80 and 77 re SG tube surveillance *.

10/23/78 Amendments 65, 65 and 62 re Appendix A SE discusses lost SG' tube plugs at Oconee Unit 1.

06/12/80 Amendments 83, 83 and 80 re secondary water chemistry monitoring program to inhibit SG tube degradation.

3/30/81 Amendments 94, 94 and 91 re change to SG tube inspection program, t

}

  • In connection with these amendments, see the SE transmitted by letter dated 1/18/80.

e l

l

(

l l

l

t ANO-2 STEAM GENERATOR TUBE LICENSING ACTIONS Date Type _

11/77 SER; NUREG-0308 - SER on Operating License Review discusses steam generator tube integrity as related to design features of the plant.

9/78 SER; NUREG-0308, Supp. 2 continues and expands the SER discussion to include preservice modifications made to tube support plate to mitigate effects of tube denting.

7/23/79 NRC letter'on Secondary Water Chemistry 9/20/79 APL letter on Secondary Water Chemistry 6/10/81 APL letter on Secondary Water Chemistry I

(

-~.

m

)

AND-2 STEAM GENERATOR TUBE IllSPECTION AND PLUGGING HISTORY

/

3 l

Primary to No' Defects No. Tubes Secondary Type of Requiring No. Tubes j

Date Inspected Leakage, one 2

' Total Defects 3 Degrad.

Reoatr Plugged / Sleeved /Pu11edt i

A/B Hot A/B Cold i

i 4/dl 448/316 448/316 None N/A Mone None

.e i

i Notes: (1) Partial inspection only. Down cold leg past drilled partial support plates'10 and 11 (401 thinning of nominal tube wall thickness).

(2) No leakage was identiflod associated with thi inspection.

1 (3) TS 4.4.5.4 Definition of a defect: Imperfections exceeding plugging limit which is t401 thinning of nominal tube wall thickness.

(4) No tubes hsve been plugged as a result of inservice inspections. Some tubes (21) were plugged prior to inittsi service.

j Type of Degradation a-Wastage b-Cracking c-IGA i

d-Pitting j

e-Fatigue I

f-Erosion / Corrosion j

g-Denting i

I 1.

i I

l 4

l

{

^

OCONEE Unit'T s

STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY No'. Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Reosir Pluqqed/ Sleeved / Pulled j

f S.G. Number AlfL Q

Q g

A B

I-0/0 0/0 40/0/4 33/0/9 Preservice 0/0 0/0 0/0/0 0/0/0 11/74 513/494 0/2

-/f 0/2 0/0/0 2/0/0 i

3/76 535/500 5/29 f/f 5/29 5/0/0 35/0/2 8/77 2541/4950 3/23 f/f 3/23 3/0/0 39/6/2 7/78 1374/1106 10/68 f/f 10/68 12/0/0 71/0/0 l

11/79 3060/7500 -

4/37 f/f 4/37 4/0/0 40/0/1 l

9/81 2872/8201 10/76 16/0 1.0 A SG 1/0 e/-

1/0 2/0/0 0/0/0 12/76 0/420 4.0 8 SG 0/3

-/e 0/3 0/0/0 4/0/0 1/77 0/124 12.0 B SG 0/2

-/e 0/2 0/0/0 2/0/0 2*/77 0/490 0.1 B SG 0/6

-/e 0/6 0/0/0 7/0/1 3/77 0/1 00 0.2 B SG 0/5

-/e 0/5 0/0/0 5/0/0 '

5/77 0/499 16.0 B SG 0/2

-/e 0/2 0/0/0 2/0/0 4/78 0/472 0.33 A SG 0/1

-/e 0/1 0/0/0 5/0/O' 7/79 0/305 0.48 8 SG 0/1

-/f 0/1 0/0/0 1/0/0 2/81 366/0 0.25 A SG 1/0 e/-

1/0 1/0/0 0/0/0 TOTALS 24/179 24/179 67/0/4 246/6/15 Or or or Or

<11/1.2%

<11/1.2%

11 1.5%

j g

p3 Type of Degradatica y,Q a-Wasta b-Crack ng c-lGA g Je d-Pitting e-Fatigue g-Denting

- g

,o f-Erosion / Corrosion fg

.I

.' 7.

/0

/0

<5/

l'.. (

i ', u

~

f,'

f,)

',' y

g%

RRRRRRRR R"

43 ma a-mp-g t

oooooooo a

<iaaaaaaaa a.

=

E Aosaaasa a"

$$h u

asa eeeecect tz

.g

= cooooooo ouo g,

Ns k

g

.g M

OT 3

%eeg

(

<s-E

  1. 8 Ee ak s

~!

a w

E:

< eeeeque tZ g

s.

oooooooo o-o w

"E Y 8

w I

s 5

set g-

=

W p4

==m 8

88 3 tm

  • en~o o n.

5 tat aco n

a m

a 5l 5:s5.55a g.a.

woum 8

5 s

7 4

2 2

82 u.

a

,e agem

(

g

. o

.s s.ss

9. s
3:ss:

C*Rtatt.

Esa Essa 3

a *&aaSA22a

  1. 4244446 m

{

m I

I v

OCONEE UNIT 3 i

l STEAM GENERATOR TIBE INSPECTION AND PLUGGING HISTORY l

e l

t Primary to No. Defects No. Tubes Se ondary Type of Requiring No. Tubes i

l Date inspected Lea 6. age, ops Total Defects Degrad.

Repair Plugged / Sleeved / Pulled I

S.G. Number M

M M

M A

B

.s 0/0 0/0 77/0/0 1/0/0 Preservice 11/76 484/455 0/0 0/0 0/0/0 0/0/0 0/0 0/0/0 1/0/0 10/77 1132/1252 0/0 I,j 6/78 946/1122 0/0 0/0 0/0/0 0/0/0 1/3 f/-

1/0 1/0/0 1/0/0 5/79 781/836 12/80 1920/3620 0/4

-/f 0/4 0/0/0 4/0/1 I

7/76 0/11 1.0 8 SG 0/1

-/e 0/1 0/0/0 3/0/0 2/77 0/142 0.2 B SG 0/1

-/e 0/1 0/0/0 11/0/0 6/77 1/120 0.2 B SG 0/1

-/e 0/1 U/0/0 1/0/0 7/77 0/146 0.4 5 SG 0/1

-/e 0/1 0/0/0 2/0/0 6/80 380/0 0/1 A SG 1/0 e/7 1/0 1/0/0 0/0/0 TOTAL 2/8 2/8 79/0/0 24/0/1

<11/<11

<11/<11

<1 %

<15 Type of Degradation a-Wastage e

b-Cracking c-lGA i

d-Pitting e-Fatigue f-Erosion / Corrosion g-Denting e

J.

(

r, ANO -l STEAM GENERATOR TUBE LICENSING ACTIONS Date M

5/27/77 Amendment #24; Provision for SG tube inspection consistent with R.G.1.83 12/20/77 Amendment #29; Deletion of annual report but retention of annual report on SG tube surveillance 4/11/79 Amendment #41; SG. tube surveillance

(

.J 90 1 i

t i

STEAM GENERATOR TUBE INSPECTION 2 0 PLUGGING HISTORY No' Defects Primary to No. Tubes Secondary Type of Requiring No. Tubes

~

Date Inspected Leakage, ope Total Defects Degrad.

Reost r Plugtved/ Sleeved / Pulled l

S.G. M m ber B

8 ALB B

B 9

2/77 490 490 0

0 N/A 0

0 0

0 2/78 3311 1342 5

0 c.e 5

0 4/0/1 0/0/0 0

0 0

0 0/0/0 0/0/0 l'

825 838 4/79 371 0

.39 3

0 c.e 3

0 3/0/0 0/0/0 7/80 9/80 548 0

.29 1

0 c.e 1

0 4/0/0 U/0/0 3

0 c.e 3

0.

7/0/0 0/0/0 1/81 1793 072 12 0

12 0

18/0/1 0/0/0 0771 0

.0771 0

.121 Of Type of Degradation a-Wastage b-Cracking c-IGA d-Pitting a

e-Fatigue f-Erosion / Corrosion g-Unknown (Originating free outer surface) i I

I i

I

RANCHO SECO STEAM GENERATOR TUBE LICENSING ACTIONS Date M

8/23/77 Tech Spec Amendment No.13 incorporated inspection requirements consistent with R.G. 1.83 Rev. 1 D

.t O

1 k

.-y

-..--.,-_-.--.,,..g w

=-a'--*-"vr'~----

m- - - - - ~ - -

---'-w--

e--

--r--*

  • ~-r

-'-m*- - - - - - -='

-w----*v'-'"----'-=

,J I

O i

RANCHO SECO STEAM GENERATOR TUBE INSPECTION MD PLUGGING I ISTORY No. Defects Primary to No. Tubes secondary Type of Requiring No. Tubes Date Inspected Leakage, ope Total Defects Degrad.

Reoair Pluqqed/ Sleeved / Pulled S.G. Number A

8 A

B_

Ap g

3_

g a

8 8/0/0 9/77 1391 51 7 4

0 g

4 0

0 11/78 91 3 864 2/80 1765 1771 1

2 g/g 1

2 1/0/0 2/0/0 0

0 2/81 929 0

2 4/0/0 E/81 0

400 (10 initially 0

2 b/g M gm. mx i

TOTAL 5

4 5

4 9/0/0 6/0/0

.011

.021

.031

.021

.06%

.0M Type of Degradation j

a-Wastage b-Cracking c-IGA d-Pittir.g e-Fatigue f-Erosion / Corrosion g-Unknown (originating from outer surface) 1 Y

e i

i

1

(

,TMI-1 STEAM GENERATOR TUBE LICENSING ACTIONS Date Tyge 12/22/78 Amendment 47 incorporated new S/G tube surveillance requirements 2/20/80 Amendment 52 implemented secondary

, chemistry requirements 4

e I

e' t

I

-. m m,_,__

m n

g o.o 9

TMI-1 STEAM GENERATOR TUBE IllSPECTION AIID PLUGGING HISTORY l

1 Primary to llo. Defects

(

No. Tubes Secondary Type of Requiring 30s. Tubes Date Inspected Leakage, ape Total Defects Degrad.

Recafr Plugged / Sleeved / Pulled i

I, S.G. Number M

g

,A[B g

A B.

A/O 0/0/0 0/0/0 3/76 490/490 0/0 1/6 h/h U/0 1/0/0 6/0/0 3/77 675/477 1/0 t/-

1/0 1/0/01 1/0/0 3/78 1825/1442 3/79 3757/1135 2/0 1/-

2/0 3/0/0 0/0/0

-/I

-/t 0/0 0/0/0 1/0/0 6/80

-/985 12/81 15531/15531

'1*'

c/

(nowunder TOTAL **

inspection)

See Note.

i

  • Not formally measured
    • This inspection relates to recent major $/G problems.

There are presently several thousand indications of defects which may require repair, but eddy current testing and evaluation is not complete. 19 tubes have been renoved for analysis.

Types of Degradation i

a-Wastage b-Cracking l

c-IGA d-Pitting e-Fatigue F-Erosion / Corrosion g-Denting h-Fretting 1-Manufacturing defect O

S.

a

9 l

/

1

(

s CRYSTAL RIVER 3 STEAM GENERATOR TUBE LICENSING ACTIONS Date Tyy_ee 9/1/78 Amendment 16 SE discusses SG repair due to damage caused by BPRA failures 9/17/80 Amendment 33 re inspection of SG tubes 7/21 / 81 Amendment 41 SE discusses potential radiological consequences of SG tube failure in connection with CR's power increase 3

e

(

J w

j CRYSTAL RIVER 3 p

l {

5 STEAN GENERATOR TUBE INSPECTION AND PLUGGING HISTORY i

No'. Defects Primary to No. Tubes Secon'ery Type of Requiring No. Tubes l

Date Inspected

  • Leakage, ope Total Defects Degrad.

Reoair Pluqqed/ Sleeved /Pul N S.G. Number A

B A

R, g

g g_

g 3,

l 1976 (preservice) 4/-/-

2/-/-

1/-

1/-/-

7/-/-

J/l 8/78 1100 470

-/-/-

16/-/-

-/h 1979

-/-/-

2/-/-

-/-

5/80 950 h/-

1/-/-

-/-/-

12/81 400 6/-/-

27/-/-

8 l

0.04%

0.181 1

  • Bubble test only Type of Degradation l

a-Wastage b-Cracking c-IGA d-Pitting e-Fa tigue f-Erosion / Corrosion g-Denting N-Nechanical wear due to pieces fmm a burnable poison rod failure 1-Free Path Obstruction j-Eddy current indication - probably from support plate 1

)

1 s

1 l

I DAVIS-BESSE l

STEAM GENERATOR TUBE LICENSING ACTIONS Date Ty3_ee 10/1/79 Amendment 21 re inspection requirements

  1. 4 4

I s

b 4

i i

i l

l k

l

-..,_r..,...

{

~

[08 m

^

l'

.1 DAVIS - BES STEAM GENERATOR TUBE INSPECTION AND PLUGGING HISTORY No'. Defects i

Primary to i

No. Tubes Secondary Type of Requiring No. Tubes Date Inspected Leakage, ape Total Defects tegrad.

Reoair Plugged / Sleeved / Pulled S.G. Number pf,B.

A B_

3/B A

81 A

B Note 5 11 6

11/0/0 6/0/0 j

In Factory 15,500/15.500 (11/71 )

(100%)

1 2

4/80 846/855 7

9 Note 3 0

0 0/0/0 0/0/0 Note 4 2

0 10/0/0 0/0/0 4/81 382/0 0.5 to 0.6 2

gpm total i

TOTAL 9

9 13 6

21.

6 0.061 0.061 (0.08%

(0.04%

0.14%

0.04%

NOTES I~

at 14th support plate Sa20% various locations 2 - all(20% various locations 3 - localized wear and " dings" 4 - believed to be due to external mechanical factor - dowel pin broke loose 5 - fabrication defects Types of Degradation a-Wastage b-Cracking c-lGA d-Pitting c-Fatigue f-Erosion / Corrosion g-Denting O

-