Text

.

4 **

' MOT / Calc No.

1-FCV-63-25 (GL 69-10)

Page /oFL PRESSURE LOCKING EVALUATION FOR REQUIRED PULLOUT FORCE (for Double Disc Solit Wedae)

,.1 e i~E ba] =INPQTS*

MOV

'1-F C V-6 3 2 5 I Valve type =

DD Spilt Wedge r

ARK No[f024gy VALVE DWG d']93-12869L EPRI NP 6516 Calc Meth

~

4 VALVE DESIGN DATA a = b m n 0.4]

theta (A) =l:

20ldeg EPRI MOV PPP INTERNAL DEslGN INFO. Ref.

l a=

1.8438 inches ro=

0.625 inches

' D1 E1 M1 N.5@jf.'87S$ [1.25 b=

0.625 inches v=

0.3 a=

((D1 + E1) / 2) / 2 =

1.84375 b=

M1/ 2 =

0.625 = ro

,(D)

Mean Seat Dia (D1+E1)/2 =

3.6875 in v= Poisson's Ratio = ""703 (d)

Stem Dia =

sm 21.625 in v

seating surfaces friction coef (S2)

Valve Seat Area ((D)^2*Pl/4=

10.68 (in)^2 based on Calc method. & EPRI results (Vf) mu/(cosA + musinA) =

0.4000 theta =

1/2 total valve (St3)

Stem Area ((d)^2*Pl/4=

l 2.07l(in)^2 disk angle (PI)

Packing Load (Calculated) =

1625 lbs Valve Seat Area Based on :

(PI)

Packing Load (Actual, average) =

> 90 lbs D1, E1 PRESSURE and TEMPERATURE DATA s2735l psi (Pb)

Pbon =

lJ 1

i

=< J2600 psi

s. a)

P up =

ma20 psi (Pd)

P down =

DP =

l 2600lpsid PRESSURE INDUCED. PRESSURE LOCKING THRUST REQUIREMENT:

THRUST = [ { (Pb - Pu) + (Pb - Pd) } * {S2} * {Vf} } - { (ST3) * (Pb) } + Pl ] + UNWEDGING WHERE:

Pb = Pressure in valve Bonnet UNWEDGING =

[

. Ollbs Pu = Pressure upstream of Valve Pd = Pressure downstream of Valve S2 = Valve Seat Area Vf = Valve Friction Factor St3 = Stem Area Pl = Packing load (maximum value)

THRUST =

8213lbs PRESSURE INDUCED. P L - MAXIMUM BONNET PRESSURE @ ACTNALVE LIMITING CAP PRESSURE = { ANLIMTH + (S2

  • Vf * (Pu + Pd)) - Pi } / { (2
  • S2 -Vf)- St3 }

PRESSURE =

3879 psi Rev.

Prepared:

Checked:

j[

e 9608130248 960806 PDR ADOCK 05000327 P

PDR

-L

)

h10\\/ Calc No.

1-FCV-63-25 (GL 69-10)

Page 2oFL l

{

PRE 9 SORE LOCKING REQUIREMENT =

8213 lbs ACTUR~ ORNALVE CAPABILITY EVALUATION CALCULATION:

1-FCV43-25 Actuator Model SMB E 5 filbs 1

Motor Start Torque (MT)

Overall Gear Ratio (OGR) 87.2 Pullout Efficiency (PE)

M0_l%

Application Factor (AF) 0.9 or 1.0 41]

4 0.6100 359.3VAC Valve Factor (VF) 1.0 or (VF/460)"2 p$0iO187j f

Stem Factor (SF)

Max Temperature (Temp) 215 F Loss Percentage (elevated temp)

$[2Q]%

Note 1 Torque Loss Factor = 1-Loss %*(Temp-104)/(356-77) 0.9149 Actuator Torque Capability = (MT

  • OGR
  • TLF
  • VF) 291.98 filbs SF =

Actuator Thrust Capability = Torque / Stem Factor 15614lbs 0.0187 Actuator Thrust / Torque Rating J33600)lbs gjS00,00jftibs Valve Weak Link Thrust / Torque Rating gj49870;lbs SF =

932.57 filbs 0.0187 Seismic Thrust / Torque Rating

  • jl336;00)lbs SF =

628.32 ftibs 0.0187 Note 1:

Reference:

Limitorque Technical Update 93-03 RESULTS:

PRESSURE LOCKING REQUIREMENT =

8213 lbs ACTUATOR / VALVE LIMITING CAPABILITY =

15614 lbs i CUT = MOTOR CAP COMMENTS:

Rev.

Prepared:

Checked:

/

-