e Progress Energy Serial: RNP-RA/07-0095 SEP 11 2007 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-26 1/LICENSE NO. DPR-23 CORRECTION TO TECHNICAL SPECIFICATIONS PAGE IN AMENDMENT 216 Ladies and Gentlemen:

License Amendment 216 for H. B. Robinson Steam Electric Plant, Unit No. 2, was issued in a July 16, 2007, letter from the NRC to Carolina Power and Light Company, "H. B. Robinson Steam Electric Plant, Unit No. 2 - Issuance of Amendment to Adopt Technical Specifications Task Force (TSTF) Standard TS Change Traveler, TSTF-447, Using the Consolidated Line Item Improvement Process (TAC No. MD4250)."

Prior to issuance of the Amendment, Carolina Power and Light Company, now doing business as Progress Energy Carolinas, Inc., had provided the NRC with camera-ready Technical Specifications (TS) pages for inclusion in the Amendment in a letter dated February 2, 2007.

Subsequent review of these pages and discussion with the NRC has identified an error in camera-ready page 3.3-30 of TS Section 3.3.3 "Post Accident Monitoring." The error was then carried over into the issued Amendment.

The error involves the inadvertent omission of the change bar adjacent to the revised Action C in Section 3.3.3. Prior to the Amendment, Action C contained a note in the Condition column that stated:

"NOTE: Not applicable to hydrogen monitor channels."

Amendment 216 removed this note. However, the change bar was not included in the camera-ready pages provided for Amendment 216 due to an administrative oversight.

The corrected TS page is attached to this letter. The only change from the issued amendment is the editorial change to add the missing change bar.

Progress Energy Carolinas, Inc.

Robinson Nuclear Plant 3581 West Entrance Road Hartsville, SC 29550

United States Nuclear Regulatory Commission Serial: RNP-RA/07-0095 Page 2 of 2 If you have any questions concerning this matter, please call Curt Castell at (843) 857-1626.

Sincerely, C. A. Castell Supervisor, Licensing/Regulatory Programs (Interim)

Attachment RAC/rac c: Dr. W. D. Travers, NRC, Region I1 M. G. Vaaler, NRR NRC Resident Inspector, HBRSEP

United States Nuclear Regulatory Commission Attachment to Serial: RNP-RA/07-0095 2 Pages (including cover page)

H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 CORRECTION TO TECHNICAL SPECIFICATIONS PAGE IN AMENDMENT 216 CORRECTED TECHNICAL SPECIFICATIONS PAGE

PAM Instrumentation 3.3.3 Actions (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one channel 7 days with two required to OPERABLE status.

channels inoperable.

D. --------- NOTE.......-D.1 Restore required 7 days Only applicable to channel to OPERABLE Functions 3, 4, 19, status.

22, 23, and 24.

One or more Functions with one required channel inoperable.

E. Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C Table 3.3.3-1 for the or D not met. channel.

F. As required by F.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Required Action E.1 and referenced in Table 3.3.3-1. F.2 Be in MODE 4. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (continued)