Tech Spec Pages for Amendment 216 to Adopt Technical Specifications Task Force (TSTF) Standard TS Change Traveler, TSTF-447, Using the Consolidated Line Item Improvement Process
ML072010236
Person / Time
Site: Robinson 
Issue date: 07/16/2007
From:
NRC/NRR/ADRO/DORL/LPLII-2
To:
REGNER, L M, DORL/LPL2-2, 415-1906
Shared Package
ML071540002 List:
References
TAC MD4250
Download: ML072010236 (4)


Text

neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; D.

Pursuant to the Act and 10 CFR Parts 30, 40 and 70, to receive, possess, and use in amounts as required any byproduct, source, or special nuclear material without restriction to chemical or physical form for sample analysis or instrument and equipment calibration or associated with radioactive apparatus or components; E.

Pursuant to the Act and 10 CFR Parts 30 and 70, to possess, but not separate, such byproduct and special. nuclear materials as may be produced by operation of the facility.

3.

This renewed license shall' be deemed to contain and is subject to the conditions specified in the following Commission regulations: 10 CFR Part 20, Section 30.34 of 10 CFR Part 30, Section 40.41 of 10 CFR Part 40, Section 50.54 and 50.59 of 10 CFR Part 50, and Section 70.32 of 10 CFR Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

A.

Maximum Power Level The licensee is authorized to operate the facility at a steady state reactor core power level not in excess of 2339 megawatts thermal.

B.

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 216 are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

(1)

For Surveillance; Requirements (SRs) that are new in Amendment 176 to Final Operating License DPR-23, the first performance is due at the end of the first surveillance interval that begins at implementation of Amendment 176. For SRs that existed prior to Amendment 176, including SRs with modified acceptance criteria and SRs whose frequency of performance is being extended, the first performance is due at the end of the first surveillance interval that begins on the date the Surveillance was last performed prior to implementation of Amendment 176.

Rqpewed Facility Operating License No. DPR-23 Amendment No. 216 I

PAM Instrumentation 3.3.3 Actions (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C.

One or more Functions C.1 Restore one channel 7 days with two required to OPERABLE status.

channels inoperable.

D. --------- NOTE --------- D.1 Restore required 7 days Only applicable to channel to OPERABLE Functions 3, 4, 19, status.

22, 23, and 24.

One or more Functions with one required channel inoperable.

E.

Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C Table 3.3.3-1 for the or D not met.

channel.

F.

As required by F.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Required Action E.1 AND and referenced in Table 3.3.3-1.

F.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (continued)

HBRSEP Unit No. 2 3..3-30 Amendment No. 216

PAM Instrumentation 3.3.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME G.

As required by G.1 Initiate action in Immediately Required Action E.1 accordance with and referenced in Specification 5.6.6.

Table 3.3.3-1.

SURVEILLANCE REQUIREMENTS


NOTE-------------------------------

SR 3.3.3.1 and SR 3.3.3.2 apply to each PAM instrumentation Function in Table 3.3.3-1; except Functions 9, 22, 23, and 24.

SR 3.3.3.3 applies only to Functions 9, 22, 23, and 24.

SURVEILLANCE FREQUENCY SR 3.3.3.1 Perform CHANNEL CHECK for each required 31 days instrumentation channel that is normally energized.

SR 3.3.3.2


NOTE------------------ 18 months Neutron detectors are excluded from CHANNEL CALIBRATION.

Perform CHANNEL CALIBRATION.

SR 3.3.3.3 NOTE -------------------- 18 months Verification of setpoint not required.

Perform TADOT.

HBRSEP Unit No. 2 3.3-31 Amendment No.216

PAM Instrumentation 3.3.3 Table 3.3.3-1 (page.1 of 1)

Post Accident Monitoring Instrumentation CONDITION REFERENCED FROM FUNCTION REQUIRED CHANNELS REQUIRED ACTION E.1 1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

Power Range Neutron Flux Source Range Neutron Flux Reactor Coolant System (RCS)

Hot Leg Temperature RCS Cold Leg Temperature RCS Pressure (Wide Range)

Refueling Water Storage Tank Level Containment Sump Water Level (Wide Range)

Containment Pressure (Wide Range)

Containment Isolation Valve Position Containment Area Radiation (High Range)

Not used Pressurizer Level Steam Generator Water Level (Narrow Range)

Condensate Storage Tank Level Core Exit Temperature--Quadrant 1 Core Exit Temperature--Quadrant 2 Core Exit Temperature--Quadrant 3 Core Exit Temperature--Quadrant 4 Auxiliary Feedwater Flow SD AFW Pump MD AFW Pump Steam Generator Pressure Containment Spray Additive Tank Level PORV Position (Primary)

PORV Block Valve Position (Primary)

Safety Valve Position (Primary) 2 2

1 per loop 1 per loop 2

2 2

2 2 per penetration flow path (a)(b) 2 2

2 per SG 2

2 (c) 2 (c) 2 (c) 2(c) 1 1

2 per SG per SG per SG 2

1 1

1 (a) Not required for isolation valves whose associated penetration is isolated by at least one closed and deactivated automatic valve, closed manual valve,.blind flange, or check valve with flow through the valve secured.

(b) Only one position indication channel is required for penetration flow paths with only one installed automatic containment isolation valve.

(c) A channel consists of one core exit thermocouple (CET).

HBRSEP Unit No. 2 3.3-32 Amendment No.

216