Letter Sequence Response to RAI |
|---|
EPID:L-2023-RNW-0017, Us Dept of Commerce, National Institute of Standards & Technology (Nist), Transmittal of Decommissioning Funding Plan (Open) TAC:L32643, (Open) |
|
MONTHYEARML20065H1612020-02-28028 February 2020 U.S. Dept. of Commerce, National Institute of Standards & Technology (NIST) - Reply to Request for Additional Information - 2019 Decommissioning Funding Plan Submittal Project stage: Response to RAI ML22293A2692022-09-27027 September 2022 Us Dept of Commerce, National Institute of Standards & Technology (Nist), Transmittal of Decommissioning Funding Plan Project stage: Request ML22348A1702022-12-17017 December 2022 Request for Supplemental Information NIST 2022 DFP Update Project stage: Request ML23060A2622023-01-24024 January 2023 National Institute of Standards and Technology (Nist), Reply to Request for Supplemental Information - 2022 Triennial Update to Decommissioning Funding Plan Project stage: Supplement ML23136B2812023-04-25025 April 2023 Historical Site Assessment for the National Institute of Standards and Technology Project stage: Other ML23136B2862023-04-25025 April 2023 Radiological Scoping Study Report for the National Institute of Standards and Technology Project stage: Other ML23136B2782023-04-25025 April 2023 Decontamination and Decommissioning Cost Estimate (Dce) for the National Institute of Standards and Technology Project stage: Other ML23136B2792023-04-30030 April 2023 NIST-TR-23-003, Appendix a - Facility Laboratory Cost Estimating Worksheets Project stage: Other ML23136B2802023-04-30030 April 2023 NIST-TR-23-003, Appendix B - Accelerator Component and Area Cost Estimating Worksheets Project stage: Other ML23136B2882023-05-16016 May 2023 Scoping Report: 144265-RPT-001, Appendix B - Scoping Surveys Project stage: Other ML23136B2852023-05-16016 May 2023 Department of Commerce, National Institute of Standards and Technology Reply to Request for Supplemental Information - 2022 Triennial Update to Decommissioning Funding Plan Project stage: Supplement ML23136B2842023-05-16016 May 2023 NIST Historical Site Assessment NIST-TR-23-001, Rev. a, Appendix B - Hsa Investigation List for All Rooms Project stage: Other ML23136B2902023-05-16016 May 2023 Scoping Report: 144265-RPT-001, Appendix D - Tennelec Results, Rev. a Project stage: Other ML23136B2872023-05-16016 May 2023 Scoping Report 144265-RPT-001, Appendix a - Scoping Survey Calibration Sheets, Rev. a Project stage: Other ML23136B2892023-05-16016 May 2023 Scoping Report: 144265-RPT-001, Appendix C - Liquid Scintillation Results, Rev. a Project stage: Other ML23220A4042023-08-0808 August 2023 Enclosure 5 RSO Delegation of Authority Project stage: Other ML23220A4002023-08-0808 August 2023 Enclosure 1: NRC Form 313 Application for Materials License Renewal Project stage: Request ML23220A4012023-08-0808 August 2023 Enclosure 2: Requested Exemptions Under 10CFR36.17 and 70.17 Project stage: Other ML23220A3992023-08-0808 August 2023 Us Dept. of Commerce, National Institute of Standards & Technology (NIST) - License Renewal Application Project stage: Other ML23220A3982023-08-0808 August 2023 Us Dept. of Commerce, National Institute of Standards & Technology (NIST) - Submittal of License Renewal Application Project stage: Other ML23271A2202023-10-0606 October 2023 Acceptance of National Institute of Standards and Technology License Renewal Application Dated August 8, 2023 Project stage: Acceptance Review ML23313A0642023-10-20020 October 2023 Us Dept. of Commerce, National Institute of Standards and Technology - Designation of Trustworthiness and Reliability Official Project stage: Other ML23289A2222023-11-13013 November 2023 Summary of Call with the U.S. Department of Commerce, National Institute of Standards and Technology: Special Nuclear Material License Number-362 Renewal Application Project stage: Other ML23355A2552023-12-0808 December 2023 National Institute of Standards and Technology Second Request to Extend Due Date for Providing Request for Additional Information Responses (NIST 2022 DFP Update) Project stage: Request ML24022A2952024-01-12012 January 2024 NIST 2022 DFP Update: Response to Request for Additional Information Project stage: Response to RAI ML23320A1322024-02-0909 February 2024 NIST LRA - RAI Project stage: Request ML23320A1352024-02-0909 February 2024 NIST LRA - RAI Transmittal Letter Project stage: RAI ML23320A1332024-02-0909 February 2024 Enclosure 1 - Request for Additional Information (Public) Project stage: RAI ML24071A1782024-03-11011 March 2024 Reply to Request for Additional Information: U.S. Department of Commerce, National Institute of Standards and Technology (NIST) Application for Renewal of Special Nuclear Materials License Number 362 - EPID L-2023-RNW-0017 Project stage: Response to RAI ML24198A1452024-07-0909 July 2024 Reply to Request for Final 2022 Decommissioning Cost Estimate and Decommissioning Funding Plan - Enterprise Project Identification Number L-2023-RNW-0017 Project stage: Request ML24248A1702024-09-18018 September 2024 U.S. Department of Commerce, National Institute of Standards and Technology - 2022 Decommissioning Cost Estimate and Decommissioning Funding Plan Triennial Update Submittal Project stage: Other ML24152A1792025-04-10010 April 2025 1 - Cover Letter - Special Nuclear Materials-362 License Renewal Transmittal Project stage: Other ML24152A1802025-04-10010 April 2025 2 - Enclosure 1 - Special Nuclear Materials-362 License Renewal Safety Evaluation Report - Public Project stage: Approval ML24152A1812025-04-10010 April 2025 3 - Enclosure 2 - Special Nuclear Materials-362 (Public) Project stage: Other 2023-04-25
[Table View] |
Text
March 11, 2024 U.S. Nuclear Regulatory Commission License No. SNM-362 ATTN: Document Control Desk Docket# 70-398 Washington, DC 20555-0001 TAC No. L32643 Osiris Siurano-Pérez, Project Manager Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
Subject:
REPLY TO REQUEST FOR ADDITIONAL INFORMATION: U.S. DEPARTMENT OF COMMERCE, NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST)
APPLICATION FOR RENEWAL OF SPECIAL NUCLEAR MATERIALS LICENSE NUMBER 362 -
ENTERPRISE PROJECT IDENTIFICATION NUMBER L-2023-RNW-0017
Dear Mr. Siurano-Pérez,
NRC identified that additional information related to the license renewal application submitted by NIST was needed to complete the technical review. On February 9, 2024, the NRC staff provided the NIST a formal request for additional information (RAI) (ML23320A135, ML23320A133 & ML23320A136).
The purpose of this submittal is to provide timely response to the RAI. In addition to the revised License Amendment Application (LRA); enclosed documents include direct responses to NRC RAIs (public and non-public), revised LRA Enclosure 4 and Enclosure 6. Anew Enclosure 7 has been added to address NRCs RAI # FP-1: Fire safety features of the facility design. The enclosures 4 & 6 contain OUO-SRI and are being submitted as non-public. Enclosure 7 is being submitted as non-public as it contains diagrams and layouts of the interior of building 245.
The following documents will not be resubmitted as they were not revised because of the RAI; they are LRA Enclosures 1,2,3, and 5 (ML23220A400, ML23220A401, ML23221A163, and ML23220A404).
Thank you for your attention to this letter and attached response. If you have further questions about this response, please contact the NIST Radiation Safety Officer, Mr. Manuel Mejias at 301-975-5800 or manny.mejias@nist.gov.
UNITED STATES DEPARTMENT OF COMMERCE National Institute of Standards and Technology Gaithersburg, Maryland 20899
Sincerely, Dr. Elizabeth A. Mackey Executive Representative to the IRSC National Institute of Standards and Technology Enclosure LRA RAI Response Enclosure LRA RAI Response (OUO-SRI) Radioactive Material for which the License is Requested (OUO-SRI) (revised) LRA Section 9, Physical Security (OUO-SRI) (revised) Fire Safety Facility Schematics cc:
Dr. Laurie Locascio, NIST Director Dr. Alan Thompson, NIST IRSC Chair Mr. Henry Wixon, NIST Chief Counsel Mr. Manuel Mejias, NIST Radiation Safety Officer ELIZABETH MACKEY Digitally signed by ELIZABETH MACKEY Date: 2024.03.11 13:50:17 -04'00'