January 10, 2024 MEMORANDUM TO:

Michael Wentzel, Chief Advanced Reactor Licensing Branch 2 Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Jorge Hernandez, Project Manager

/RA/

Advanced Reactor Licensing Branch 2 Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE OCTOBER 11, 2023, PUBLIC MEETING WITH X ENERGY, LLC. (X-ENERGY), SPENT FUEL MANAGEMENT WHITE PAPER (EPID NO. L-2018-LRM-0076)

Meeting Information:

Applicant: X ENERGY, LLC. (X-energy)

Docket/Project No.(s): 99902071 Public Meeting Notice Agencywide Documents Access and Management System (ADAMS)

Accession No.: ML23268A054 Applicant Presentation Slides ADAMS Accession No.: ML23258A105 Meeting Attendees: See the enclosure for a list of meeting attendees.

CONTACT:

Jorge Hernandez, NRR/DANU 301-287-9096

Meeting Summary:

The U.S. Nuclear Regulatory Commission (NRC) staff conducted the meeting in accordance with NRC Management Directive 3.5, Attendance at NRC Staff-Sponsored Meetings (ML21180A271).

The purpose of the meeting was for X-energy to present their proposed plan for spent fuel management, which will be submitted for NRC review in a white paper.

The X-energy staffs presentation discussed the following topics:

Design overview of the Tri-structural Isotropic (TRISO) particle fuel and fuel cycle facilities.

Xe-100 functional arrangement for spent fuel transfer and storage facilities.

Regulatory approach for spent fuel management during operations and post-operating license storage. X-energy explained that NUREG-2215, Standard Review Plan for Spent Fuel Dry Storage Systems and Facilities, provides guidelines for design and concept of operations that are more applicable to the Xe-100 dry intermediate spent fuel storage facility than the guidance provided in NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition, for wet spent fuel storage facilities.

Compliance strategy options for criticality accident requirements under 10 CFR 50.68.

Contents of the proposed white paper.

The NRC staff asked the following questions:

Are the fuel pebbles individually traceable? X-energy indicated they are not.

Has X-energy considered using the NUREG-0800 guidelines along with NUREG-2215?

X-energy indicated most significant aspects of NUREG-0800 are concerned with maintaining safe water level, which are not applicable to the Xe-100 design.

Will there be details of instrumentation and controls in the white paper? X-energy indicated that only as an overview and that additional details will be included in a future licensing topical report.

In addition, during the closed portion of the meeting, NRC and X-energy staff discussed proprietary details pertaining to the design of the spent fuel facilities.

No regulatory decisions were made as a result of this meeting.

Project No. 99902071

Enclosure:

List of Meeting Attendees cc: X-energy Xe-100 via GovDelivery

SUBJECT:

SUMMARY

OF THE NOVEMBER 9, 2023, PUBLIC MEETING WITH X ENERGY, LLC. (X-ENERGY), SPENT FUEL MANAGEMENT WHITE PAPER (EPID NO. L-2018-LRM-0076) DATED: JAN 10, 2024 DISTRIBUTION:

PUBLIC RidsNrrDanuUal1 Resource RidsNrrDanuUal2 Resource RidsNrrDanu Resource JAshcraft DBeacon BWhite IJung YDiaz AMuniz GOberson RStattel KBanovac LKingsbury ADAMS Accession Number: ML24004A021 NRR-001 OFFICE NRR/DANU/UAL2/PM NRR/DANU/UAL2/BC NRR/DANU/UAL2/PM NAME JHernandez MWentzel JHernandez DATE 01 / 09 / 2024 01 / 10 / 2024 01 / 10 / 2024 OFFICIAL RECORD COPY

Enclosure List of Meeting Attendees For the October 11, 2023 Public Meeting With X Energy, LLC. (X-Energy), Spent Fuel Management White Paper Open Meeting Name Organization Adrian Muniz U.S. Nuclear Regulatory Commission (NRC)

Bernie White NRC Dan Beacon NRC Greg Oberson NRC Ian Jung NRC Jorge Hernandez Munoz NRC Joseph Ashcraft NRC Kristina Banovac NRC Lance Kingsbury NRC Michael Wentzel NRC Ondra Dukes NRC AJ Clore X-energy Brandon Hartle X-energy Eddie Grant X-energy Jessica Maddocks X-energy Maggie Staiger X-energy Mark Natale X-energy Sarah Gibboney X-energy Steve Vaughn X-energy Carl Friesen U.S. Department of Energy Rasheed Auguste U.S. Department of Energy Timothy Stuhldreher U.S. Department of Energy Charlyne Smith Breakthrough Institute Nicole Schlichting Kairos Power Timothy Polich RoPower Edwin Lyman Union of Concerned Scientists Carlyn Greene UxC, LLC Dominik Muszynski Member of the Public Toru Nakatsuka Member of the Public Closed Meeting Name Organization Adrian Muniz NRC Bernie White NRC Dan Beacon NRC Greg Oberson NRC Ian Jung NRC Kristina Banovac NRC Michael Wentzel NRC Ondra Dukes NRC AJ Clore X-energy Jessica Maddocks X-energy Maggie Staiger X-energy

2 Name Organization Mark Natale X-energy Sarah Gibboney X-energy Steve Vaughn X-energy Carl Friesen U.S. Department of Energy Rasheed Auguste U.S. Department of Energy Timothy Stuhldreher U.S. Department of Energy