Letter Sequence Other |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance, Acceptance
- Supplement
Results
Other: ML21223A048, ML21223A049, ML21223A050, ML21223A056, ML22028A372, ML22196A086, ML22243A274, ML22243A278, ML22325A338, ML23005A002, ML23005A006, ML23005A275, ML23013A340, ML23013A341, ML23013A342, ML23013A343, ML23013A344, ML23013A345, ML23013A346, ML23013A347, ML23076A272, ML23076A275, ML23076A278, ML23263B123, ML23263B124, ML23263B125, ML23263B127, ML24178A432, ML24178A433, ML24178A434, ML24178A435, ML24178A436, ML24178A437, ML24178A438
|
MONTHYEARML21068A3612021-03-0909 March 2021 International, Submittal of HI-STORM 100 Multipurpose Canister Storage System Amendment 16 Request Project stage: Request ML21179A1792021-07-12012 July 2021 Acceptance Review of Request for Amendment No. 16 to Certificate of Compliance No. 1014 for HI-STORM 100 Multipurpose Canister Storage System, Request for Supplemental Information Project stage: Acceptance Review ML21237A0422021-07-23023 July 2021, 25 August 2021 Summary of July 27, 2021, Public Meeting on HI-STORM 100, Amendment No. 16, Graded Approach Project stage: Request ML21201A0282021-07-23023 July 2021 Handout for Meeting with Holtec on HI-STORM 100 Amendment No. 16 (July 27, 2021) Project stage: Request ML21223A0452021-08-10010 August 2021, 11 August 2021 HI-STORM 100 Amendment 16 Responses to Requests for Supplemental Information Project stage: Request ML21223A0562021-08-10010 August 2021 Attachment 10: Affidavit in Accordance with 10 CFR 2.390 Project stage: Other ML21223A0502021-08-11011 August 2021 Attachment 4: HI-STORM 100 FSAR Proposed Revision 21A, Changed Pages (non-proprietary) Project stage: Other ML21223A0492021-08-11011 August 2021 Attachment 3: HI-STORM 100 Amendment 16 Certificate of Compliance Appendix D, Changed Pages (non-proprietary) Project stage: Other ML21223A0462021-08-11011 August 2021 HI-STORM 100 Amendment 16 Responses to Requests for Supplemental Information Project stage: Supplement ML21223A0482021-08-11011 August 2021 Attachment 2: HI-STORM 100 Amendment 16 Rsi Responses (non-proprietary) Project stage: Other ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach Project stage: Meeting ML22028A3712022-01-28028 January 2022 International, HI-STORM 100 Amendment 16 Additional Information on Graded Approach Project stage: Request ML22028A3722022-01-28028 January 2022 International, HI-STORM 100 Amendment 16 Additional Information on Graded Approach Project stage: Other ML22048C2222022-02-17017 February 2022 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Project stage: Request ML22053A1302022-03-17017 March 2022 Acceptance Review Request for Amendment No. 16 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System (Docket No. 72-1014, CAC No. 001028, EPID: L-2021-LLA-0039) Project stage: Acceptance Review ML22167A1202022-07-0101 July 2022 Amendment No. 16 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information First Batch Project stage: RAI ML22196A0862022-07-15015 July 2022 International, Schedule for Responses to HI-STORM 100 Amendment 16 Requests for Additional Information Batch 1 Project stage: Other ML22243A2742022-08-31031 August 2022 Attachment 4: HI-STORM 100 FSAR Proposed Revision 21B, Changed Pages (non-proprietary) Project stage: Other ML22243A2692022-08-31031 August 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batches 1 and 2) Project stage: Request ML22243A2722022-08-31031 August 2022 Attachment 2: Holtec Response to Request for Additional Information (Batch 1 and Partial Batch 2) Project stage: Response to RAI ML22243A2702022-08-31031 August 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batches 1 and 2) Project stage: Response to RAI ML22243A2782022-08-31031 August 2022 Attachment 8: Affidavit in Accordance with 10 CFR 2.390 Project stage: Other ML22249A3472022-09-0606 September 2022, 9 September 2022 International, HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 2) Project stage: Request ML22249A3482022-09-0909 September 2022 International, HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 2) Project stage: Response to RAI ML22276A2872022-10-0303 October 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 3) Project stage: Response to RAI ML22276A2862022-10-0303 October 2022 HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 3) Project stage: Request ML22325A3382022-11-21021 November 2022 Schedule for Responses to HI-STORM 100 Amendment 16 Requests for Additional Information Batch 4 Project stage: Other ML22335A4552022-12-13013 December 2022 Amendment 16 to Certificate of Compliance 1014 for Hi-Storm 100 RAI Batch 5 Project stage: Request ML22335A4572022-12-13013 December 2022 Enclosure 1- Amendment 16 to Certificate of Compliance No. 1014 for Hi-Storm 100 Multipurpose Canister Storage System Request for Additional Information Batch 5 Project stage: RAI ML22335A4562022-12-13013 December 2022 Letter - Amendment 16 to Certificate of Compliance No. 1014 for Hi-Storm 100 Multipurpose Canister Storage System - Request for Additional Information Batch 5 Project stage: RAI ML23005A0012023-01-0404 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) Project stage: Response to RAI ML23005A0062023-01-0404 January 2023 Attachment 4 - HI-STORM 100 FSAR Proposed Text Changes, Changed Pages Project stage: Other ML23005A0002023-01-0404 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) Project stage: Request ML23005A0022023-01-0404 January 2023 Attachment 6 - Affidavit of Kimberly Manzione Project stage: Other ML23005A0042023-01-0404 January 2023 Attachment 2 - HI-STORM 100 Amendment 16 Response to Request for Additional Information (Batch 4) Project stage: Response to RAI ML23005A2752023-01-0404 January 2023 Attachment 2 - Affidavit of Kimberly Manzione Project stage: Other ML23005A2732023-01-0505 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 4) – Additional Supporting Document Project stage: Response to RAI ML23013A3412023-01-13013 January 2023 Attachment 3 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix a, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3432023-01-13013 January 2023 Attachment 5 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix C, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3402023-01-13013 January 2023 Attachment 2 - HI-STORM 100 Amendment 16 RAI Responses Batch 5 (Non-Proprietary) Project stage: Other ML23013A3452023-01-13013 January 2023 Attachment 7 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix A-100U, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3462023-01-13013 January 2023 Attachment 8 - HI-STORM 100 FSAR Proposed Revision 21E, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3442023-01-13013 January 2023 Attachment 6 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix D, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3422023-01-13013 January 2023 Attachment 4 - HI-STORM 100 Amendment 16 Certificate of Compliance Appendix B, Changed Pages (Non-Proprietary) Project stage: Other ML23013A3382023-01-13013 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 5) Project stage: Response to RAI ML23013A3472023-01-13013 January 2023 Attachment 9 - Affidavit of Kimberly Manzione Project stage: Other ML23013A3372023-01-13013 January 2023 International HI-STORM 100 Amendment 16 Responses to Requests for Additional Information (Batch 5) Project stage: Request ML23076A2782023-03-17017 March 2023 Attachment 5: Affidavit Project stage: Other ML23076A2752023-03-17017 March 2023 Attachment 3: HI-STORM 100 FSAR Proposed Text Changes, Changed Pages Project stage: Other ML23076A2742023-03-17017 March 2023 Attachment 2: Holtec Response to Request for Additional Information (Batch 4) Project stage: Response to RAI 2022-02-17
[Table View] |
Text
Page 1 of 1 Holtec Response to Request for Additional Information (Second Round)
Docket No. 72-1014 Certificate of Compliance No. 1014 Amendment No. 16 to HI-STORM 100 Multipurpose Canister Storage System Shielding Evaluation RAI 5-5 Provide calculations demonstrating that the HI-STORM 100 storage system design meets regulatory annual dose limits for a real individual located beyond the controlled area in Title 10 of the Code of Federal Regulations (10 CFR) Section 72.104(a) with the proposed limits for burnup and enrichment in final safety analysis report (FSAR) tables 2.1.28 and 2.1.29.
As part of Proposed Change No. 7, the applicant proposed replacing the tables of correlation coefficients used to determine appropriate content limits for meeting regulatory dose rate requirements with a table of allowable burnup and cooling time for zirconium based cladding fuel within the ventilated overpacks for the following canisters: MPC-24/24E/24EF, MPC-32/32F and MPC-68/68FF. These new limits on allowable contents produce source terms that would result in higher dose rates than the source terms produced from previously approved correlations and correlation coefficients. The applicant did not provide calculated annual dose for a real individual located beyond the controlled area with the limiting source terms produced from the proposed content limits.
The NRC staff makes findings that regulations associated with cask design in 10 CFR 72.236 are met during design certification. Although there are technical specification dose rate limits on the storage cask surface that have not changed and would serve to limit dose, these are very limited in number, and do not provide enough information to justify that potential loadings allowed by FSAR tables 2.1.28 and 2.1.29 that also meet technical specification dose rate limits would subsequently meet the dose limits in 10 CFR 72.104(a) at the previously specified distances to the controlled area boundary for the HI-STORM 100.
These calculations are needed by the NRC staff to be able to make a finding per 10 CFR 72.236(d) that the system has appropriate shielding to meet annual dose limits in 10 CFR 72.104(a).
Holtec RAI Response:
The calculations are performed for HI-STORM 100S Version B loaded with the MPC-24, MPC-32 or MPC-68 canister with the limiting contents in Tables 2.1.28 and 2.1.29 of the FSAR, and the annual dose to an individual at or beyond the controlled area boundary as well as the minimum distance required to meet the dose limits in 10 CFR 72.104(a) are determined. The results of the calculations are added to Section 5.4.11 of the HI-STORM 100 FSAR.
Holtec Letter 5014969 Attachment 1