Text
August 8, 2023
SUBJECT:
SEABROOK STATION - INTEGRATED INSPECTION REPORT 05000443/2023002
Dear Bob Coffey:
On June 30, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Seabrook Station. On July 24, 2023, the NRC inspectors discussed the results of this inspection with Brian Booth, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.
One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. One Severity Level IV violation without an associated finding is documented in this report. We are treating these violations as non-cited violations (NCVs) consistent with Section 2.3.2 of the Enforcement Policy.
If you contest the violations or the significance or severity of the violations documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:
Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement; and the NRC Resident Inspector at Seabrook Station.
If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region I; and the NRC Resident Inspector at Seabrook Station. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Matt R. Young, Chief Projects Branch 2 Division of Operating Reactor Safety
Docket No. 05000443 License No. NPF-86
Enclosure:
As stated
Inspection Report
Docket Number:
05000443
License Number:
Report Number:
Enterprise Identifier: I-2023-002-0035
Licensee:
NextEra Energy Seabrook, LLC
Facility:
Seabrook Station
Location:
Seabrook, New Hampshire
Inspection Dates:
April 1, 2023 to June 30, 2023
Inspectors:
T. Daun, Senior Resident Inspector
C. Newport, Senior Resident Inspector
S. Flanagan, Acting Resident Inspector
P. Cataldo, Senior Reactor Inspector
N. Eckhoff, Health Physicist
Approved By:
Matt R. Young, Chief
Projects Branch 2
Division of Operating Reactor Safety
SUMMARY
The U.S. NRC continued monitoring the licensees performance by conducting an integrated inspection at Seabrook Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
Failure to Establish Continuous Fire Watch on Fire Door Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000443/2023002-01 Open/Closed
[H.4] -
Teamwork 71111.05 The inspectors identified a Green finding and associated non-cited violation of Seabrook Station Facility Operating License Condition 2.F when the licensee failed to establish a continuous fire watch on fire door C107 which was open in the A essential switchgear room.
Failure to Make Required 50.72(b)(3) Notifications Cornerstone Severity Cross-Cutting Aspect Report Section Not Applicable Severity Level IV NCV 05000443/2023002-02 Open/Closed Not Applicable 71153 The inspectors identified a Severity Level IV non-cited violation of 10 CFR 50.72(b)(3)(iv) with three examples when NextEra failed to make three required event notifications.
Additional Tracking Items
None.
PLANT STATUS
Seabrook Station began the inspection period in refueling outage 22 (OR22) that commenced on March 31, 2023. On May 12, 2023, as the station was returning to 100 percent power, a heater drain pump failed requiring a rapid down power to 48 percent power for repairs. On May 14, 2023, the station returned to 100 percent power. Seabrook remained at or near 100 percent rated thermal power for the remainder of the inspection period.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed activities described in IMC 2515, Appendix D, Plant Status, conducted routine reviews using IP 71152, Problem Identification and Resolution, observed risk significant activities, and completed on-site portions of IPs. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.01 - Adverse Weather Protection
Seasonal Extreme Weather (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated readiness for seasonal extreme weather conditions prior to the onset of seasonal high temperatures for the following system: service water and control building heating ventilation and air conditioning
71111.04 - Equipment Alignment
Partial Walkdown (IP Section 03.01) (5 Samples)
The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:
- (1) Reactor water level instruments during decreased reactor pressure vessel water inventory for vessel disassembly on April 6, 2023 (2)
'B' shutdown cooling system during decreased water inventory in reactor vessel on April 7, 2023
- (3) Spent fuel pool cooling system following core offload to spent fuel pool on April 10, 2023 (4)
'A' cooling tower service water with 'B' cooling tower service water out-of-service for maintenance on April 11, 2023 (5)
'B' residual heat removal system after aligning for emergency core cooling on May 5, 2023
71111.05 - Fire Protection
Fire Area Walkdown and Inspection (IP Section 03.01) (5 Samples)
The inspectors evaluated the implementation of the fire protection program by conducting a walkdown and performing a review to verify program compliance, equipment functionality, material condition, and operational readiness of the following fire areas:
- (1) Containment building operating deck (C-F-3-Z) on April 13, 2023
- (2) Containment building middle level (C-F-2-Z) on April 21, 2023
- (3) Containment building lower level (C-F-1-Z) on April 27, 2023 (4)
'A' switchgear room (CB-F-1A-A) on June 1, 2023
- (5) Primary auxiliary building ventilation rooms (PAB-F-3B-Z) on June 12, 2023
Fire Brigade Drill Performance (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated the on-site fire brigade training and performance during an unannounced fire drill on May 19, 2023
71111.06 - Flood Protection Measures
Flooding (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated internal flooding mitigation protections in the control building cable spreading room on June 8, 2023
71111.07A - Heat Exchanger/Sink Performance
Annual Review (IP Section 03.01) (1 Sample)
The inspectors evaluated readiness and performance of:
(1) 'B' primary component cooling water heat exchanger
===71111.08P - In-service Inspection Activities (PWR)
The inspectors verified that the reactor coolant system boundary, risk significant piping system boundaries, and the containment boundary are appropriately monitored for degradation and that repairs and replacements were appropriately fabricated, examined and accepted by reviewing activities from April 10, 2023 through April 29, 2023.
PWR In-service Inspection Activities - Nondestructive Examination (NDE) and Welding Activities (IP Section 03.01)===
(1)
- Manual ultrasonic and visual examinations of the -26' containment liner during repairs at the 220-240 azimuth (NDE Report SB1-IWE-23-239)
- Manual ultrasonic examination of 6-inch safety injection pipe-to-elbow welds S1-0251-07-02 and 03 (NDE Report SB1-UT-23-034 and 035)
- Visual examination of control rod drive mechanism canopy sleeve and clamp (NDE Report under WO 40807466-01)
- Class 1 welding activities and progressive liquid penetrant examinations associated with the steam generator bowl drain replacement under NRC-approved relief request 4RA-22-01 (ML23073A156) and engineering change EC297778
- Liquid penetrant inspection following welding of Class 2 piping high point vent of 'A' charging pump (EC298147, and WO 40854907-01)
- Verification of the performance of structural examinations of containment in accordance with IWE requirements, and associated with the 15-year 10 CFR 50 Appendix J, Type A Integrated Leak Rate Test (WO 40803307, EX1803.001 "Reactor Containment Integrated Leakage Rate Test - Type A,"
Revision 12)
PWR In-service Inspection Activities - Vessel Upper Head Penetration Inspection Activities (IP Section 03.02) (1 Sample)
The inspectors verified that the licensee conducted the following reactor vessel upper head penetration inspections and addressed any identified defects appropriately:
- (1) Reactor pressure vessel head bare metal visual examination of penetrations 2, 3, 66, 76, 77, and 78 (NDE Report SB1-VT-23-055)
PWR In-service Inspection Activities - Boric Acid Corrosion Control Inspection Activities (IP Section 03.03) (1 Sample)
The inspectors verified the licensee is managing the boric acid corrosion control program through a review of the following evaluations:
(1)
- Boric acid identified on 1-CS-FT-160 (AR 02405971)
- Boric acid identified on 1-RH-V59 (AR 02453747)
- Boric acid identified downstream of 1-CS-V17 (AR 02449495)
- Boric acid identified on flange of 1-RH-E-9B (AR 02453006)
- Boric acid identified on swing-check 1-RH-V29 (AR 02453748)
71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (1 Sample)
- (1) The inspectors observed and evaluated licensed operator performance in the control room during reactor coolant system heatup, reactor startup, approach to criticality, and low power physics testing in May 2023
Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)
- (1) The inspectors observed and evaluated licensed operator training conducted in the plant reference simulator on June 14, 2023
71111.12 - Maintenance Effectiveness
Maintenance Effectiveness (IP Section 03.01) (1 Sample)
The inspectors evaluated the effectiveness of maintenance to ensure the following structures, systems, and components remain capable of performing their intended function:
- (1) Control room building air system in accordance with the Maintenance Rule Program on June 8, 2023
Quality Control (IP Section 03.02) (1 Sample)
The inspectors evaluated the effectiveness of maintenance and quality control activities to ensure the following structures, systems, and components remains capable of performing their intended function:
- (1) Quality control verifications are properly specified in accordance with the Quality Assurance Program and are implemented as specified during outage work activities
71111.13 - Maintenance Risk Assessments and Emergent Work Control
Risk Assessment and Management (IP Section 03.01) (5 Samples)
The inspectors evaluated the accuracy and completeness of risk assessments for the following planned and emergent work activities to ensure configuration changes and appropriate work controls were addressed:
- (1) Elevated (shutdown) risk during reduced reactor coolant inventory on April 5, 2023
- (2) Risk management actions required for containment closure in Mode 5 on April 6, 2023
- (3) Risk management actions associated with all ocean service water and one cooling tower service water out-of-service for maintenance on April 11, 2023
- (4) Elevated (yellow) risk during emergency diesel generator 'B' planned maintenance window the week of June 6, 2023
- (5) Elevated (yellow) risk during emergency diesel generator 'A' planned maintenance window the week of June 20, 2023
71111.15 - Operability Determinations and Functionality Assessments
Operability Determination or Functionality Assessment (IP Section 03.01) (3 Samples)
The inspectors evaluated the licensee's justifications and actions associated with the following operability determinations and functionality assessments:
(1)
'B' emergency bus failure and restoration (AR 02454289) on April 12, 2023 (2)
'B' emergency diesel following incorrect fluid addition to crankcase oil sump (AR
===02458425) on April 23, 2023
- (3) Emergency feedwater check valve cycling (AR 02458869*) on May 30, 2023
71111.20 - Refueling and Other Outage Activities
Refueling/Other Outage Sample (IP Section 03.01)===
- (1) The inspectors evaluated OR22 activities from April 1, 2023 through May 7, 2023
71111.24 - Testing and Maintenance of Equipment Important to Risk
The inspectors evaluated the following testing and maintenance activities to verify system operability and/or functionality:
Post-Maintenance Testing (PMT) (IP Section 03.01) (6 Samples)
(1)
'A' centrifugal charging pump following rotating element replacement on April 16, 2023 (2)
'B' containment sump isolation valve encapsulation tank as left leak rate test following installation of manways following valve inspection on April 17, 2023 (3)
'B' diesel generator sequencer power supply replacements on April 30, 2023 (4)
'D' vital inverter after replacement on June 1, 2023 (5)
'B' emergency diesel generator after the planned maintenance window on June 9, 2023 (6)
'A' emergency diesel generator after the planned maintenance window on June 26, 2023
Surveillance Testing (IP Section 03.01) (3 Samples)
(1)
'A' auto safety injection, phase 'A' containment isolation, containment ventilation isolation and main steam isolation actuation surveillance test on April 3, 2023
- (2) Reactor containment integrated leakage rate test on April 29, 2023 (3)
'B' emergency diesel generator engineered safeguards test on May 2, 2023
In-service Testing (IP Section 03.01) (1 Sample)
(1) 'B' centrifugal charging comprehensive pump test on April 7, 2023
Containment Isolation Valve Testing (IP Section 03.01) (1 Sample)
- (1) Local leak rate testing chemical and volume control normal letdown penetration X37A on April 21, 2023
71114.06 - Drill Evaluation
Drill/Training Evolution Observation (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated the conduct of a routine, full participation emergency planning drill on June 14,
RADIATION SAFETY
71124.01 - Radiological Hazard Assessment and Exposure Controls
Radiological Hazard Assessment (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated how the licensee identifies the magnitude and extent of radiation levels and the concentrations and quantities of radioactive materials and how the licensee assesses radiological hazards
Instructions to Workers (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated how the licensee instructs workers on plant related radiological hazards and the radiation protection requirements intended to protect workers from those hazards
Contamination and Radioactive Material Control (IP Section 03.03) (2 Samples)
The inspectors observed/evaluated the following licensee processes for monitoring and controlling contamination and radioactive material:
- (1) Observed egress of personnel and material at the radiologically controlled area alternate access point, along with technician response to personal contamination alarms
- (2) Observed counting of survey material in a low background area to ensure accuracy of survey results
Radiological Hazards Control and Work Coverage (IP Section 03.04) (4 Samples)
The inspectors evaluated the licensee's control of radiological hazards for the following radiological work:
- (1) Observed surveying of work area after pipe cut during steam generator bowl work
- (2) Observed surveys after valve removal in demineralizer alley
- (3) Outage reactor vessel disassembly and reassembly as low as reasonably achievable plan - package number 23-01
- (4) Outage reactor head peening as low as reasonably achievable plan - package number 23-02
High Radiation Area and Very High Radiation Area Controls (IP Section 03.05) (3 Samples)
The inspectors evaluated licensee controls of the following High Radiation Areas and Very High Radiation Areas:
- (1) Locked high radiation areas in the primary auxiliary building
- (2) Locked high radiation area controls for under the reactor vessel head during reactor head peening
- (3) Observed a briefing for valve work performed in a locked high radiation area Radiation Worker Performance and Radiation Protection Technician Proficiency (IP Section 03.06) (1 Sample)
- (1) The inspectors evaluated radiation worker and radiation protection technician performance as it pertains to radiation protection requirements
71124.03 - In-Plant Airborne Radioactivity Control and Mitigation
Permanent Ventilation Systems (IP Section 03.01) (1 Sample)
The inspectors evaluated the configuration of the following permanently installed ventilation systems:
- (1) Primary auxiliary building cleanup filter PAH-F-16
Temporary Ventilation Systems (IP Section 03.02) (1 Sample)
The inspectors evaluated the configuration of the following temporary ventilation systems:
- (1) Temporary ventilation used in the waste storage building
Use of Respiratory Protection Devices (IP Section 03.03) (1 Sample)
- (1) The inspectors evaluated the licensees use of respiratory protection devices
Self-Contained Breathing Apparatus for Emergency Use (IP Section 03.04) (1 Sample)
- (1) The inspectors evaluated the licensees use and maintenance of self-contained breathing apparatuses
71124.04 - Occupational Dose Assessment
Source Term Characterization (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated licensee performance as it pertains to radioactive source term characterization
External Dosimetry (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated how the licensee processes, stores, and uses external dosimetry
Internal Dosimetry (IP Section 03.03) (2 Samples)
The inspectors evaluated the following internal dose assessments:
- (1) Whole body counts related to AR 02455099
- (2) Reviewed calibration records of whole body count equipment
Special Dosimetric Situations (IP Section 03.04) (2 Samples)
The inspectors evaluated the following special dosimetric situations:
- (1) Neutron dosimetry program
- (2) Declared pregnant worker program
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification
The inspectors verified licensee performance indicators submittals listed below:
MS05: Safety System Functional Failures (IP Section 02.04)===
- (1) For the period April 1, 2022 through March 31, 2023
MS06: Emergency AC Power Systems (IP Section 02.05) (1 Sample)
- (1) For the period April 1, 2022 through March 31, 2023
MS07: High Pressure Injection Systems (IP Section 02.06) (1 Sample)
- (1) For the period April 1, 2022 through March 31, 2023
===71152S - Semi-Annual Trend Problem Identification and Resolution
Semi-Annual Trend Review (IP Section 03.02)===
- (1) The inspectors reviewed the Seabrook corrective action program for trends that might be indicative of more significant safety issues
71153 - Follow Up of Events and Notices of Enforcement Discretion Reporting (IP Section 03.05)
- (1) Reportability follow up on actuation of the 'B' emergency diesel generator emergency power sequencer
- (2) Reportability follow up on actuation of the reactor program system during digital rod position indication system surveillance testing
INSPECTION RESULTS
Failure to Establish Continuous Fire Watch on Fire Door Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems
Green NCV 05000443/2023002-01 Open/Closed
[H.4] -
Teamwork 71111.05 The inspectors identified a Green finding and associated non-cited violation of Seabrook Station Facility Operating License Condition 2.F when the licensee failed to establish a continuous fire watch on fire door C107 which was open in the A essential switchgear room.
Description:
On June 1, 2023, during a walkdown of the essential switchgear room NRC inspectors identified that fire door C107 was held open by extension cords pinched in the door. No fire watch was seen at the door or in either the essential switchgear room or the stairwell the door goes to. The inspectors immediately notified the control room. The control room confirmed a continuous fire watch should have been established by the work group and dispatched the fire brigade leader to investigate.
It was discovered that work was being performed in the stairwell that required power cords to be run from the essential switchgear room to the stair well for electrical power. The work group was briefed by the control room on the requirement to station a continuous fire watch while the door was open for the cords but when the work group left, they removed all the cords but missed one that was still in door. This was left unnoticed by the work group until the inspectors discovered it.
This fire door falls under the licensees Technical Requirements 11 for Fire Rated Assemblies which prescribes the actions for one or more fire rated sealing devices being nonfunctional as establishing a continuous fire watch on at least one side of the affected assembly within one hour or verify the functionality of fire detectors on at least one side of the nonfunctional assembly and establish an hourly fire watch patrol. The appropriate compensatory action for this degraded fire door was determined by the licensee to be a continuous fire watch on at least one side of the affected assembly.
Corrective Actions: Corrective actions included entering the appropriate actions in the Technical Requirements Manual and implementing the required continuous fire watch until the degraded fire barrier had been restored. NextEra also wrote an AR for which directs an evaluation for the reason and to provide coaching to the work group. (AR2459087)
Corrective Action References: 2459087
Performance Assessment:
Performance Deficiency: The inspectors determined that Seabrook's failure to establish appropriate compensatory measures for a degraded fire rated assembly as required by the Technical Requirements Manual was a performance deficiency that was reasonably within Seabrooks ability to foresee and correct and should have been prevented. Specifically, a continuous fire watch was not established when fire door C107 was degraded.
Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the Protection Against External Factors attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the degraded condition identified with the open fire door would have adversely impacted the essential switchgear room's fire barrier functionality.
(IMC0612 Appendix E example 2.d)
Significance: The inspectors assessed the significance of the finding using IMC 0609 Appendix F, Fire Protection and Post - Fire Safe Shutdown SDP. The inspectors determined this issue to be of very low safety significance, Green, in Phase 1, Task 1.4.4.F, Fire Confinement, because the degraded fire barrier only adversely impacted one fire area and did not impact any other adjoining fire areas.
Cross-Cutting Aspect: H.4 - Teamwork: Individuals and work groups communicate and coordinate their activities within and across organizational boundaries to ensure nuclear safety is maintained. Lack of communication or understanding between work personnel that ordered the continuous fire watch and the assigned personnel to the fire watch resulted in a misunderstanding of duties and responsibilities of the position.
Enforcement:
Violation: Seabrook Station, Unit 1 Facility Operating License Condition 2.F requires, in part, NextEra to implement and maintain effect all provisions of the approved fire protection program as described in the Updated Final Safety Analysis Report, the Fire Protection Program Report, and the Fire Protection and Safe Shutdown Capability Report, as supplemented. Supplement 7 of the Safety Evaluation Report approved NextEra's request to establish fire protection program limiting conditions for operation and action statements that provide a level of protection equivalent to that provided by the fire protection sections of the Westinghouse Standard Technical Specifications. This commitment was incorporated into Section 9.5-1 of the Seabrook Updated Final Safety Analysis Report which states, in part, limiting conditions for operation, action statements, and surveillance requirements for the fire protection program are prescribed in the Seabrook Station Technical Requirements Manual.
The Seabrook Station Technical Requirements Manual, Technical Requirement 11, Fire Rated Assemblies, establishes the limiting condition for operation, in part, to be all sealing devices in fire rated assemblies shall be functional while the equipment protected by the fire rated assemblies is required to be operable. The Technical Requirement 11 prescribes the actions for one or more fire rated sealing devices being nonfunctional as establishing a continuous fire watch on at least one side of the affected assembly within one hour or verify the functionality of fire detectors on at least one side of the nonfunctional assembly and establish an hourly fire watch patrol. Contrary to the above, on June 1, 2023, Seabrook did not establish required compensatory actions of Technical Requirement 11.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
Failure to Make Required 50.72(b)(3) Notifications Cornerstone Severity Cross-Cutting Aspect Report Section Not Applicable Severity Level IV NCV 05000443/2023002-02 Open/Closed
Not Applicable 71153 The inspectors identified a Severity Level IV non-cited violation of 10 CFR 50.72(b)(3)(iv) with three examples when NextEra failed to make three required event notifications.
Description:
On April 12, 2023, while Seabrook Station was in Mode 6 at zero percent power, a valid actuation signal of the B emergency diesel generator emergency power sequencer occurred due to a loss of power to the B emergency Bus E6. The loss resulted from spurious operation of emergency power sequencer remote manual override relays that opened the unit auxiliary transformer feeder breaker to bus E6. Subsequently, the loss of power to bus E6 resulted in a valid actuation of an emergency power sequencer starting signal to the B emergency diesel generator. At the time of this event, the B emergency diesel generator was removed from service for scheduled maintenance and therefore, did not start.
Within eight hours of the event occurring inspectors questioned the licensee on the reportability of the event but at the time the licensee determined the event was not reportable because the emergency diesel generator was tagged out-of-service. The inspectors reviewed NUREG-1022, Rev.3, Event Report Guidelines, and noted Section 3.2.6 example 3 states, The event is reportable because the actuation logic for the emergency diesel generator start was completed, even though the emergency diesel generator did not power the safety buses.
On May 6, 2023, at 15:52 with Seabrook Station in Mode 3 at zero percent power, while performing digital rod position indication system surveillance testing, shutdown bank 'E' stopped withdrawing. In response, the reactor trip breakers were manually opened, initiating a valid actuation of the reactor protection system. Subsequently on May 6, at 22:53 while continuing to perform digital rod position indication system surveillance testing, shutdown bank 'C 'stopped inserting. Reactor trip breakers were manually opened, initiating a valid actuation of the reactor protection system. Initially the operators had determined these two reactor protection system actuations were not reportable. On May 11, 2023 the resident inspectors questioned why two events were not reported as required by 10 CFR 50.72(b)(3)(iv)(A) "Eight Hour Reports", for the valid actuation of the reactor protection system.
Corrective Actions: AR 02458443 was generated to perform common cause evaluation and make the missed reports as required by 10 CFR 50.72. NextEra reported the valid actuation of the 'B' emergency diesel generator emergency power sequencer and the two valid actuations of the reactor program system as required by 50.72 (EN 56564 and EN 56565) on June 8, 2023.
Corrective Action References: ARs 02458443, 02454289, 02456934, 02456952, 02459323, 02454246
Performance Assessment:
The inspectors determined this violation was associated with a minor performance deficiency. Failing to submit the event notifications as required by 10 CFR 50.72 within the required time was a performance deficiency that was reasonably within NextEras ability to foresee and correct and should have been prevented. The inspectors reviewed the condition for Reactor Oversight Process significance and concluded there was no associated finding. Because this violation involves the traditional enforcement process and does not have an underlying technical violation that would be considered more than minor, a cross-cutting aspect is not assigned to this violation in accordance with IMC 0612.
Enforcement:
The ROPs significance determination process does not specifically consider the regulatory process impact in its assessment of licensee performance. Therefore, it is necessary to address this violation which impedes the NRCs ability to regulate using traditional enforcement to adequately deter non-compliance.
Severity: This violation was assessed using Section 2.2.4 of the NRCs Enforcement Policy.
Using the example listed in Section 6.9.d.9, A licensee fails to make a report required by 10 CFR 50.72, the issue was determined to be a Severity Level IV violation.
Violation: 10 CFR 50.72(b)(3)(iv)(A), "Eight Hour Reports," requires the licensee to notify the NRC for any event or condition that results in valid actuation of any of the systems listed in paragraph (b)(3)(iv)(B) of this section, except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation. Contrary to the above, NextEra did not notify the NRC within eight hours of the occurrence of a condition at Seabrook Unit 1 as evidenced by the following examples:
- (1) On April 12, 2023 NextEra did not notify the NRC within eight hours of the occurrence of a condition at Seabrook Unit 1 that resulted in a valid actuation of the 'B' emergency diesel generator emergency power sequencer.
- (2) On May 6, 2023 at 15:52 NextEra did not notify the NRC within eight hours of the occurrence of a condition at Seabrook Unit 1 that resulted in a valid actuation of the reactor program system.
- (3) On May 6, 2023 at 22:53 NextEra did not notify the NRC within eight hours of the occurrence of a condition at Seabrook Unit 1 that resulted in a valid actuation of the reactor protection system.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
Observation: Semi-Annual Trend Review 71152S The inspectors evaluated a sample of issues and events that occurred over the first and second quarters of 2023. The evaluation did not reveal any new trends that could indicate a more significant safety issue. The inspectors determined that, in most cases, the issues were appropriately evaluated by NextEra for potential trends at a low threshold, and resolved within the scope of the corrective action program.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On April 14, 2023, the inspectors presented the 71124.01 inspection results to Brian Booth, Site Vice President, and other members of the licensee staff.
- On April 20, 2023, the inspectors presented the 71111.08P inspection results to Jeff Sobotka, Engineering Director, and other members of the licensee staff.
- On May 25, 2023, the inspectors presented the 71124.03 and 71124.04 inspection results to Brian Booth, Site Vice President, and other members of the licensee staff.
- On July 24, 2023, the inspectors presented the integrated inspection results to Brian Booth, Site Vice President, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Procedures
Seasonal Readiness
Revision 40
Work Orders
40617315
40738017
4078192
40804835
40834945
40835181
Corrective Action
Documents
2196368
Drawings
PID-1-RH-
B20660
Residual Heat Removal System Overview
Revision 003
PID-1-SF-F20482
Spent Fuel Pool Cooling and Clean Up System Detail
Revision 11
Miscellaneous
DBD-SF-01
Spent Fuel Pool Cooling, Purification, and Cleanup System
Revision 3
Procedures
OS1000.04
Plant Cooldown From Hot Standby to Cold Shutdown
Revision 72
OS1000.12
Operation with RCS at reduced Inventory
Revision 19
OS1001.11
Reactor Coolant System Shutdown Level Instrumentation
Revision 17
OS1001.12
Draining the Reactor Coolant System for Vessel Head
Removal
Revision 23
OS1013.04
Residual Heat Removal Train B Startup and Operation
Revision 38
OS1016.05
Service Water Cooling Tower Operation
Revision 40
OS1016.12
Contingency Cooling Tower Pump Restoration During
Cooling Tower Maintenance
Revision 2
Corrective Action
Documents
Resulting from
Inspection
2459087
Procedures
FP 5.1
Fire Brigade Response
Revision 07
Revision 6
Fire Response
Revision 3
OS1200.00
Response to Fire or Fire Alarm Actuation
Revision 28
OS1200.05
Response to EFW Pump House Fire
Revision 00
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Corrective Action
Documents
00120752
Drawings
1-NHY-310431
Control Building, General Electrical Arrangement
Revision 30
Procedures
MA5.7
Station Barriers, Penetration Seals, and Fire Wrap
Revision 20
Corrective Action
Documents
2454023
2454415
2454487
Miscellaneous
FPLE-213
Final Eddy Current Inspection Report For: PCCW E-17B
04/13/2023
Work Orders
40806953
40829216
71111.11Q Procedures
Conduct of Operations
Revision 38
Conduct of Infrequently Performed Tests or Evolutions
Revision 19
OS1000.02
Plant Startup From Hot Standby To Minimum Load
Revision 47
OS1000.07
Approach to Criticality
Revision 16
RS1735
Reactivity Calculations
Revision 10
RS1737
Post Refuel Low Power Physics Testing
Revision 14
Corrective Action
Documents
2432518
2453360
2454004
2455093
2455101
2456467
2545140
Drawings
PID-1-CBA-
B20307
Control Building Air Conditioning System Safety Related
Chilled Water System Train A
Revision 8
Procedures
ER-AA100-2002
Maintenance Rule Program Administration
Revision 13
Work Orders
40363937
40719515
40829214
40876569
40876632
237635
Corrective Action
2453437
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Documents
2453447
2453483
2453553
2453595
2453649
2453704
Procedures
Guarded Equipment
Revision 46
OS1016.11
Contingency Ocean Pump Restoration for SW Work
Activities with Ocean Service Water Pumps Not in Service
Revision 12
OS1056.03
Containment Penetrations
Revision 16
OS1401.12
RCS Reduced Inventory Containment Integrity Verification
Revision 5
WM-AA-203-1006 Critical Maintenance Management
Revision 18
Work Orders
40844256
Corrective Action
Documents
2447144
2453822
2454246
2454289
2454290
2454753
2454778
2458425
2458457
2458527
2459800
Corrective Action
Documents
Resulting from
Inspection
2458869
Drawings
1-NHY-310102,
Sh A72a
4160V Bus 1-E6 RAT Inc Line Three Line Diagram
Revision 7
1-NHY-310102,
Sh A72b
4160V Bus 1-E6 RAT Inc Line Close Schematic
Revision 14
1-NHY-310102,
4160V Bus 1-E6 RAT Inc Line Trip Schematic
Revision 9
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Sh A72c
1-NHY-310102,
Sh A73e
4160V Bus 1-E6 P.T.S. Schematic Diagram
Revision 10
1-NHY-310102,
Sh A73f
4160V Bus 1-E6 P.T.S. Auxiliary Contacts
Revision 10
1-NHY-310102,
Sh A73h
4160V Bus 1-E6 PT'S. Schematic Diagram
Revision 7
Work Orders
40803551
40803602
40882367
40883359
Drawings
9763-F-101402
Containment Concrete Mat Sections
Revision 14
9763-F-101462
Containment Liner Bottom Plate
Revision 8
9763-F-805139
Containment Liner Floor Leak Chase Piping System Piping
Arrangement
Revision 10
FP01925-06
Seabrook Station Unit No. 1 Bottom Leak Chase - Erection
Revision 0
Engineering
Changes
298541
Design Change Package for Containment Boundary Change
to Include Embedded Liner Leak Chase System
Revision 0
Miscellaneous
445860-SBSAG-
Containment Shell Structure Axisymmetric Analysis
Revision 0
9763.006-80-1
Containment Design Specification
Revision 8
CS-23-CALC
Containment Embedded Liner Leak Chase System
Structural Evaluation
Revision 0
Corrective Action
Documents
2454401
2454409
Miscellaneous
OR22 Outage Safety Review Supporting Documentation,
Seabrook Nuclear Plant
Procedures
ON1090.04
Containment Entry
Revision 43
OS1000.03
Plant Shutdown From Minimum Load To Hot Standby
Revision 40
OS1000.04
Plant Cooldown From Hot Standby To Cold Shutdown
Revision 71
OS1000.06
Power Decrease
Revision 30
OX1406.12
Month Containment And Containment Spray
Recirculation Sump Surveillance
Revision 17
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
SM 7.31
Shutdown Safety Review And Safety Assessment
Revision 02
Corrective Action
Documents
2317995
2411459
2454285
2454455
2454623
2454629
2454753
2455034
2456062
2456181
2456182
2459359
2459413
2459415
2459684
2459690
2460574
2460704
2460764
Drawings
1-NHY-300229
Installation of Electrical Raceway and Supports
Revision 2
1-NHY-310108
Emergency Power Sequencer System Schematic Diagram
Revision 6
Procedures
ES1804.056
CBS-TK-101A and CBS-TK-101B Encapsulation Tank
Leakage Rate Test
Revision 1
EX1803.001
Reactor Containment Integrated Leakage Rate Test - Type
A
Revision 12
EX1803.003
Reactor Containment Type B and C Leakage Rate Tests
Revision 19
LS0567
MS0539.28
A-EDG Coolant Recirculation, Draining and Refilling
Revision 19
MS0539.54
B-EDG Coolant Recirculation, Draining and Refilling
OX1426.03
Emergency Power Sequencer 18 month Operability Test
Revision 11
OX1426.32
Diesel Generator 1B 36 Month Operability Surveillance
Revision 29
OX1456.92
Centrifugal Charging Comprehensive Pump Test
Revision 19
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
OX1456.92
Centrifugal Charging Comprehensive Pump Test
Revision 19
OX1456.93
Train B SI, Phase A, CVI & MSI Actuation 18 Month
Surveillance
Revision 27
OX1456.96
Train A SI, Phase A, CVI & MSI Actuation 18 Month
Surveillance
Revision 24
Work Orders
40394846
40427243
40605097
40728214
40782885
40803307
40803583
40806895
40806896
40807046
40807047
40807052
40807117
40807583
40811961
40825215
40844205
40844321
40844718
40845313
40854907
40877477
40879331