MONTHYEARML19221B7422019-08-30030 August 2019 Proprietary Determination Letter for ANP-10337, Revision 0, Supplement 1P, Revision 0, Deformable Spacer Grid Element RAI Response Project stage: RAI ML19347C1932019-12-10010 December 2019 Email Transmittal of Request for Additional Information Questions Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: RAI ML20083K3862020-03-26026 March 2020 Round 1 Request for Additional Information Questions for the Review of Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology (Non-Proprietary) Project stage: RAI ML20335A2182020-11-20020 November 2020 Framatome Inc. Response to Request for Additional Information Regarding ANP-10339P, Revision 0, ARITA-ARTEMIS/RELAP Integrated Transient Analysis Methodology Project stage: Response to RAI ML20338A1602020-12-10010 December 2020 December 7 - 11, 2020, Regulatory Audit Plan for Framatome Inc. Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML20338A1652020-12-10010 December 2020 Regulatory Audit Plan for Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project No. 728 Project stage: Other ML21026A0012021-02-0909 February 2021 Audit Report Letter for Framatome Topical Report ANP-10229P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML21055A8102021-03-0101 March 2021 March 3, 4, 24, 25, and 26, 2021 Regulatory Audit Plan for Framatome Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project No. 728 EPID L-2018-TOP-0034 Project stage: Other ML21055A8202021-03-0101 March 2021 March 3, 4, 24, 25, and 26, 2021, Regulatory Audit Plan Letter for Framatome Inc. Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML21110A1482021-05-0404 May 2021 April 22, 2021, Audit Plan for Framatome Inc. Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML21110A1472021-05-0404 May 2021 April 22, 2021, Audit Plan for Framatome Inc. Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology (EPID L-2018-TOP-0034) (Letter) Project stage: Other ML21159A1432021-06-11011 June 2021 June 15, 2021, Regulatory Audit Plan for Framatome Inc. Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML21187A1262021-07-0909 July 2021 July 9, 2021 Audit Plan for Framatome Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML21204A1012021-07-27027 July 2021 August 11-12, 2021, Regulatory Audit Plan for Framatome Inc. Topical Report, ANP-10339P, Revision 0, Arita - ARTEMIS-RELAP Integrated Transient Analysis Methodology Project stage: Other ML21309A1052021-11-0808 November 2021 November 8, 2021 Audit Plan for Framatome Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML22109A1212022-04-22022 April 2022 April 20 - 21, and 28, 2022, Regulatory Audit Plan for Framatome Inc. Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML22097A2642022-04-26026 April 2022 U.S. Nuclear Regulatory Commissions Revised Schedule for Review of Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Approval ML22200A0612022-07-25025 July 2022 Report for 2021 - 2022, Regulatory Audits Regarding Framatome Inc. Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML22259A0012022-10-0505 October 2022 Schedule Change Letter for Framatome Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other PMNS20221134, Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology2022-10-31031 October 2022 Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Request ML22357A0822023-01-0909 January 2023 The U.S. Nuclear Regulatory Commissions Revised Schedule for the Review of Framatome’S Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Approval ML23006A2522023-01-17017 January 2023 Summary of Closed Hybrid Meeting with Framatome Inc. and the U. S. Nuclear Regulatory Commission for Topical Report, Anp 10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Meeting PMNS20230079, Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology2023-01-30030 January 2023 Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Request ML23072A3862023-04-0606 April 2023 Summary of March 2, 3023, Closed Meeting with Framatome Inc. and the U.S. Nuclear Regulatory Commission for Topical Report, ANP-10339P, Revision 0, ARITA-ARTEMIS/RELAP Integrated Transient Analysis Methodology Project stage: Meeting PMNS20230725, Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology2023-06-0909 June 2023 Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Request ML23177A2582023-07-10010 July 2023 Summary of June 20, 2023, Closed Meeting with Framatome Inc. and the U.S. Nuclear Regulatory Commission for Topical Report, Anp 10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Meeting PMNS20231147, Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology2023-10-0606 October 2023 Closed Meeting with the Nuclear Regulatory Commission and Framatome Regarding Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Request ML23233A1392023-10-16016 October 2023 Final Safety Evaluation for Framatome Topical Report Anp 10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology (EPID L 2018-TOP-0034) Letter Project stage: Approval ML23299A2322023-10-16016 October 2023 Final Safety Evaluation for Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology - Non-Proprietary Project stage: Approval ML23299A2402023-10-16016 October 2023 Final Safety Evaluation for Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology (Appendix IV) - Non-Proprietary Project stage: Approval ML23305A0642023-11-0505 November 2023 Summary of October 19, 2023, Closed Meeting with Framatome Inc. and the U.S. Nuclear Regulatory Commission for Topical Report ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Meeting ML24044A0622024-02-13013 February 2024 Withholding Determination for Publication of Framatome Topical Report, ANP-10339P, Rev. 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML24044A0632024-02-13013 February 2024 Transmittal Withholding Determination for Publication of Framatome Topical Report, ANP-10339P, Rev. 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Project stage: Other ML24040A1792024-04-16016 April 2024 Verification for Publication of Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Topical Report Project stage: Other ML24040A1762024-04-22022 April 2024 Verification for Publication of Framatome Topical Report, ANP-10339P, Revision 0, Arita - Artemis/Relap Integrated Transient Analysis Methodology Transmittal (EPID L-2018-TOP-0034) - Email Project stage: Other 2022-04-22
[Table View] |
Text
November 16, 2021 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
NOVEMBER 8, 2021, REGULATORY AUDIT PLAN FOR FRAMATOME INC.
TOPICAL REPORT, ANP-10339P, REVISION 0, ARITA - ARTEMIS/RELAP INTEGRATED TRANSIENT ANALYSIS METHODOLOGY (EPID L-2018-TOP-0034)
Dear Mr. Peters:
By letter dated August 28, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18242A443), Framatome, Inc. (Framatome) submitted Topical Report (TR) ANP-10339P, Revision 0, ARITA - ARTEMIS/RELAP Integrated Transient Analysis Methodology (ADAMS Package No. ML18242A480), to the U.S. Nuclear Regulatory Commission (NRC) for review and approval. ANP-10339P, Revision 0 (ARITA) presents a coupled code system and evaluation models for the analysis of pressurized water reactor non-loss-of-coolant accident events identified in NUREG-0800, Chapter 15, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition -
Transient and Accident Analysis.
The NRC staff technical review of this TR is ongoing. The NRC staff will perform a virtual regulatory audit on November 3, 2021. The NRC staff determined that this regulatory audit is needed to facilitate the review. Previous audits were held on December 7-11, 2020 (ADAMS Package Accession No. ML21026A007), March 3-4 and 25-26, 2021 (ADAMS Package Accession No. ML21055A702), April 22, 2021 (ADAMS Package Accession No. ML21110A149), June 15, 2021 (ADAMS Accession No. ML21159A143), July 9, 2021 (ADAMS Accession No. ML21187A126), and August 11-12, 2021 (ADAMS Accession No. ML21204A101). Enclosed for your information is a copy of the audit plan the NRC staff will follow.
Please contact Ngola Otto at 301-415-6695 or via e-mail at Ngola.Otto@nrc.gov with any questions you may have regarding this letter.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041
Enclosure:
Audit Plan (Non-Proprietary)
Enclosure REGULATORY AUDIT PLAN FOR FRAMATOME TOPICAL REPORT ANP-10339P, REVISION 0, ARITA - ARTEMIS/RELAP INTEGRATED TRANSIENT ANALYSIS METHODOLOGY PROJECT NO. 728 EPID L-2018-TOP-0034
1.0 BACKGROUND
By letter dated August 28, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18242A443), Framatome, Inc. (Framatome) submitted Topical Report (TR) ANP-10339P, Revision 0, ARITA - ARTEMIS/RELAP Integrated Transient Analysis Methodology (ADAMS Package No. ML18242A480) to the U.S. Nuclear Regulatory Commission (NRC) for review and approval for licensing applications. ANP-10339P, Revision 0 (ARITA) presents a coupled code system and evaluation models for the analysis of pressurized water reactor non-loss-of-coolant accident (non-LOCA) events identified in Chapter 15 of NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (SRP). In December 2018, the NRC staff completed an acceptance review of the TR and found additional information was necessary (ADAMS Accession No. ML18345A159) before a formal review effort could begin. The necessary supplemental information was submitted by Framatome in March 2019 (ADAMS Accession No. ML19078A253). The NRC staffs review also relies upon information submitted by Framatome in March 2020, July 2020, November 2020, and June 2021 (ADAMS Accession Nos. ML20097E381, ML20237F458, ML20335A218, and ML21162A080, respectively) in response to request for additional information (RAI) questions from the NRC staff.
The NRC staff has identified that many of Framatomes RAI responses do not fully address the staffs concerns. Therefore, the NRC staff conducted regulatory audits in December 2020 (ADAMS Package Accession No. ML21026A007), March 2021 (ADAMS Package Accession No. ML21055A702), April 22, 2021 (ADAMS Package Accession No. ML21110A149), June 15, 2021 (ADAMS Accession No. ML21159A143), and July 9, 2021 (ADAMS Accession No. ML21187A126), and August 11-12, 2021 (ADAMS Accession No. ML21204A101) to increase efficiency in the review, facilitate discussion, and close the open items. At the close of each of these audits, both the NRC staff and Framatome staff concluded that additional regulatory audits of this nature would further enhance the efficiency of the review.
The NRC staff will conduct this virtual audit under the guidance provided in LIC-500 (Topical Report Process) and LIC-111 (Regulatory Audits).
2.0 REGULATORY AUDIT BASES Regulatory guidance for the review of fuel system materials and designs and adherence to Title 10 of the Code of Federal Regulations, Appendix A to Part 50, General Design Criteria (GDC)-10, Reactor Design, GDC-27, Combined Reactivity Control Systems Capability, and GDC-35, Emergency Core Cooling, is provided in NUREG-0800, Section 4.2, Fuel System Design. In accordance with SRP Section 4.2, the objectives of the fuel system safety review are to provide reasonable assurance that: (1) the fuel system is not damaged as a result of normal operation and anticipated operational occurrences, (2) fuel system damage is never so severe as to prevent control rod insertion when it is required, (3) the number of fuel rod failures is not underestimated for postulated accidents, and (4) coolability is always maintained.
3.0 REGULATORY AUDIT SCOPE The NRC staff will conduct a one-day audit online. This audit is expected to include discussion between the NRC staff and Framatome staff regarding areas of technical disagreement identified, and open items from the RAI responses. Details regarding the discussions and open items are provided below.
4.0 INFORMATION NEEDS The NRC staff requests that Framatome make available appropriate engineer(s) with knowledge of ARITA and any appropriate references, to address questions by the NRC staff.
Documents referenced in the TR should also be made available.
Discussion Topics This audit will focus on the following RAI responses, which were submitted June 2, 2021 (ADAMS Package Accession No. ML21162A080):
RAIs - 33, 35, 39, 40, 41, 42, 43, 44, 45, 46, 48, 49, 61, 68, 69, 70, 74, 75, 77, 78, 81, 82, 88, 89, 90, and 91 5.0 TEAM ASSIGNMENTS Kevin Heller, Technical Reviewer (NRR/DSS/SFNB)
John Lehning, Technical Reviewer (NRR/DSS/SFNB)
Joshua Kaizer, Technical Reviewer (NRR/DSS/SFNB)
Ngola Otto, Project Manager (NRR/DORL/LLPB)
Ken Geelhood, Pacific Northwest National Laboratory (PNNL)
Bruce Schmitt, PNNL Dave Engel, PNNL David Richmond, PNNL 6.0 LOGISTICS Audit Date: Wednesday, November 8, 2021.
The audit is scheduled to begin at 9:00 a.m. Eastern Standard Time. Time will be allocated for specific topics during the day of the audit as presented below:
Audit Agenda Wednesday AM Major Discussion Topics PM Major Discussion Topics
/ Next Steps The audit will be performed using the WebEx online platform and log-in information provided by Framatome.
7.0 DELIVERABLES A regulatory audit summary will be provided within 90 days of the completion of the audit.
ML21309A105 (Audit Plan)
OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DSS/SFNB/BC NRR/DORL/LLPB/BC NAME NOtto DHarrison RLukes DMorey DATE 11/5/2021 11/15/2021 11/16 /2021 11/16 /2021