OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION February 9, 2021 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.

3315 Old Forest Road Lynchburg, VA 24501

SUBJECT:

AUDIT REPORT DECEMBER 7 - 11, 2020, REGULATORY AUDIT FOR FRAMATOME INC. TOPICAL REPORT ANP-10339P, REVISION 0, ARITA -

ARTEMIS/RELAP INTEGRATED TRANSIENT ANALYSIS METHODOLOGY (EPID L-2018-TOP-0034)

Dear Mr. Peters:

By letter dated August 28, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18242A443), Framatome, Inc., submitted Topical Report (TR)

ANP-10339P, Revision 0, ARITA - ARTEMIS/RELAP Integrated Transient Analysis Methodology (ADAMS Package No. ML18242A480), to the U.S. Nuclear Regulatory Commission (NRC) for review and approval. The proposed TR presents a coupled code system and evaluation models for the analysis of most pressurized water reactor (PWR) non-Loss-of-Coolant Accident events identified in Chapter 15, Transient and Accident Analysis, of NUREG-0800 (Standard Review Plan).

On December 7 through 11, 2020, the NRC staff conducted a virtual regulatory audit to discuss major topics of the TR review associated with the request for additional information (RAI) responses received in March 2019, March 2020, July 2020, and November 2020 (ADAMS Package Accession Nos. ML19078A260, ML20097E582, ML20237F488, and ML20335A217, respectively). The results of the audit provided additional information to support the NRC staff safety evaluation of the TR. The audit report is enclosed.

NOTICE: The enclosure to this transmittal letter has proprietary information, once this letter is separated from the enclosure it is decontrolled.

OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Please contact Ngola Otto at 301-415-6695 or via e-mail at Ngola.Otto@nrc.gov with any questions you may have regarding this letter.

Sincerely,

/RA/

Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041 Project No. 728

Enclosure:

Audit Report (Proprietary)

ML21026A007 (Package)

ML21026A001 (Letter)

ML21026A005 (Audit Report)

OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DSS/SFNB/BC NRR/DORL/LLPB/BC NAME NOtto DHarrison RLukes DMorey DATE 1/25/2021 2/2/2021 2/5/2021 2/9/2021