JAFP-98-0091, Monthly Operating Rept for Feb 1998 for JAFNPP

From kanterella
(Redirected from ML20248L336)
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1998 for JAFNPP
ML20248L336
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/28/1998
From: Michael Colomb, Gao Y
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
JAFP-98-0091, JAFP-98-91, NUDOCS 9803190361
Download: ML20248L336 (6)


Text

. _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ - _ - _ _ _ .

! J;mes A. FitzP; trick I

~

.* Nucirr Prw:t PI:nt e 268 Lake Road

  • P.O. Box 41 Lycoming, New York 13093 315-342 3840 4 NewYorkPower uicno.i a. coiome

& Authority site executive Omcer March 11,1998 JAFP-98-0091

)

U.S. Nuclear Regulatory Commission Mail Station P1-137 Washington, D.C. 20555 Attention . Document Control Desk

SUBJECT:

OPERATING STATUS REPORT

Reference:

DOCKET NO. 50-333 1

l

Dear Sir:

l Enclosed please find the James A. FitzPatrick Nuclear Power Plant j Operating Status Report for the month of February, 1998.  ;

1 If there are any questions concerning this report, please contact I Yan Gao, System Engineer, at (315) 349-6353.

Very truly yours, t

a d

4.-

MICHAEL J. COLOMB SITE EXECUTIVE OF' CER MJC:

Enclosure CC: T. Landers JAF Departmtif Heads White Plains Office New York Office JTS JAFP File l g

.. n Lbd*

i 9eo3190361 98022e DR ADOCK0500g3 R

J $

e I

i l

l i

i

)

i i

l f

i J.

, NEW YORK POWER AUTHORITY

+

JAMES A. FITZPATRICK NUCLEAR POWER PLANT OPERATING DATA REPORT REPORT MONTH: FEBRUARY, 1998 DOCKET NO.: 50-333 UNIT NAME: FITZPATRICK DATE: Maren 4, 1998 COMPLETED BY: YAN GAO TELEPHONE: (315)349-6353 OPERATING STATUS j

....................................... l

1. Unit Name: FITZPATRICK  : NOTES:  :
2. Reporting Period: 380201 - 980228  :  :
3. Licensed Thermal Power (MWT): 2536  :  :
4. Nameplate Rating (Gross MWE): 'oWO  :  : I S. Design Electrical Rating (Net MWE): 816.0  :  :
6. ' Maximum Dependable Capacity (Gross MWE) 813.0  :  :
7. Maximum Dependable Capacity (Net MWE) 7W4  :  :
8. If changes occur in capacity ratings (Items 3-7) since last report, give reasons: 1 Item 6 and 7 were recomputed based on 1997 data, j j
9. Power level to which restricted, if any (Net MWE): j
10. Reasons for restrictions, if any:

THIS HONTH YR-TO-DATE CUMULATIVE

11. Hours.in Reporting Period: 672.00 1416.00 198049.00 i
12. Number of Hours Reactor was Critical: 672,00 1416.00 142942.70 1
13. Reactor Reserve Shutdown Hours: 0 0 0
14. Hours Generator On-Line 672.00 1416.00 138363.10
15. Unit Reserve Shutdown Hours: 0 0 0
16. Gross Thermal Energy Generated (MWH): 1695480.00 3569256.00 309720228.0
17. Gross Electrical Energy Generated (MWH): 570200.00 1200720.00 104880070.0

-18. Net Electrical Energy Generated (MWH): 553885.00 1165775.00 100897330.0

19. Unit Service Factor: 100.00 100.00 69.86
20. Unit Availability Factor: 100.00 100.00 69.86
21. Unit Capacity Factor (using MDC Net): 104.94 104.82 71.69
22. Unit Capacity Factor (using DER Net): 101.01 100.89 62-.43
23. Unit Forced Outage Rate: 00.00 00.00 11.83
24. Shutdowns scheduled over next 6 months (type, date, and duration of each):

l

25. 'If shutdown at end of report period, estimated date of startup:
26. Units in Test Status (prior to commercial operation): FORECAST ACHIEVED Initial Criticality Initial Electricity Commercial Operation l

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PIANT AVERAGE DAILY UNIT POWER LEVEL REPORT MONTH: FEBRUARY, 1998 DOCKET No.: 50-333 UNIT NAME: FITZPATRICK DATE: .

March 4, 1998 COMPLETED BY: YAN GAO TELEPHONE: (315)349-6353 DAY NET AVERAGE DAILY POWER LEVEL DAY NET AVERAGE DAILY POWER LEVEL

! 1 828 17 828 2 828 18 828 3 828 19 828 4 828 20 828 5 828 21 820 6 828 22 828 7 741 23 828 8 824 24 827 9 828 25 828 10 828 26 827 11 828 27 827 12 828 28 828 13 828 29 14 828 30 15 828 31 16 828 l

l

3Zc 5 T E(

- TrN1 N CFE -

0I aA3 O UOSE 5FMY( ,

I TE R NL CC TNEI AN SOCF

E NII Y ER ITL)
B VR A R IU

.:  : TC RRE OE NM DE EN CE ER GAOLPF(

R TE A TO RT TN EH ON IRST E  : LP CE V

BPTR KTEPE DE I EO CITML NR UREP ONAOE AF XOHE DUDCT EO EFSR 4

ST U

A C

M T A N R A MC D L AS A P R O CCDL SIE R TUD E

CO DE LLANE YW AAMIC R O MPONENT :UUOTU E T OT I P DNNTND H R R OAAUOE T ORO HMMACR T

O H A P E . . . . . .

T E E 8 M12345 9 UL R 9 3 9

A C S 1 S 3Tgg CODE U N ,

R E NN Y N O

WKOR E I OCDA P I T UR ET S N R T T A

N O N E EP K RTU B

HFE C V E I S I E R M RA L A X

O P T  :

E Y Z I H T T WI N E G R N D N O S EF U O M

O HFTW IN ET ) N )

N TOTO HC N E N

. E UD TAE I C I T M H A A A R S R L

I L L O P N P S P X OD X E E E IN E M R (

T TA (

A EE S C IG R J RT RN O REASON U TI R)

LR SNERN EIVEI IO A RAI A FE RTLL C YTAAP TNGR RNX NANORTOE ENITOSI(

_ MELATIT

_ PTELANAR

_  : INUUPIRE

- H RS NUIFGEMEH OQAEEPDPT D ATyfN SEMRROAOO A

E . . . . . . . .

RABCDEFGH

-_ TYPE 2 D

E E L T DU A

D ED CE RH OC FS O. FS

_ N

  • ;,7 l
NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCIE.AR POWER PIANT NARRATIVE SUt44ARY OF OPERATING EXPERIENCE REPORT MONTH
FEBRUARY, 1998 DOCKET No: 50-333 UNIT NAME: FITZPATRICK DATE: March 4, 1998 COMPLETED BY: YAN GAO TELEPHONE:(315)349-6353 The FitzPatrick plant remained at full power for most of the month of February 1998, except on February 7, power was reduced to about 90% for control rod pattern adjustment.

l l

. - - . - - - - - . - - _ - - - - _ - _ . - - - . _ - _ . - - - - - _ _ - _ _