Forwards Util Reporting Incident on 720727 Re Failure of Inboard Primary Containment Isolation Valve in Reactor Core Isolation Cooling Sys at Facility.Related Info Encl.W/O Ltr
ML20234E037
Person / Time
Site: 05000000, Quad Cities
Issue date: 08/14/1972
From: Skovholt D
US ATOMIC ENERGY COMMISSION (AEC)
To: Seiss C, Siess C
Advisory Committee on Reactor Safeguards
Shared Package
ML20234A777 List: ... further results
References
FOIA-87-40 NUDOCS 8707070429
Download: ML20234E037 (5)


Text

___

/",[ 4%,

UNITED STATES h.Dd/p

! [/ h )

ATOMIC ENERGY COMMISSION WASm NGTON, D.C. 20545 A pJ.

s

%,J e August 14, 1972 Dacket No. 50-265 Dr. Chester P. Siess Chaiman, Advisory Cordttee on Reactor Safeguards U. S. Atomic Energy Comission Washington, D. C.

20545

Dear Dr. Siess:

Sixteen copies of the following are transmitted for the Comittee's infor::ntion:

letter from Corranwealth Edison Company dated August 3, 1972, reporting an incident which occurred at 4:00 p.m.

on July 27 mgarding the failum of the inboard prima 17 containment isolation valve in the Beactor Com Isolation Cooling System at Quad-Cities Nuclear Power Station Unit 2.

r....ee L'

i e

.. n or -

Sincerely, ypph; /kn Yh Donald J.lSkovholt Assistant Director for Reactor Operations Division of Beactor Licensing

Enclosures:

As stated

-3 B707070429 B70610,

FOIA PDR 1

PDR THOMAse7-40

[)

.~

g 0FFICIA1, USE ONLY SUFFtBENT NO.156 CATEGORY B p.g nA, Quad Cities Unit 1 August 21, 1972 hb '

,2; ry BE Valve Malfunction

?

Caussonwesith Edison company letter dated July 10. 1972 reports that, during a test, the final injection valve on the RCIC system failed to open. The valve had been operated just before the test and later in the day, after the failure, was opened manually. Torque switch settings were increased and proper operation was demonstrated.

No ACRS action is recommended.

The enclosed z.aterial may be discarded after your review.

(JCM)

Quad Cities Unit 2 10 01 Cable Tray Fire L

ACRS Commonwealth Edison Company letter dated July 24. 1972 reports a ftre in two electrical cable trays on July 16, 1972. Initial indications of a problem appeared at about 1:30 an and a search was initiated, at about 3:30 am a small fire was discovered in two electrical cable trays in the TIF room. No smoka was detected and the fire appeared to have satinguished itself. Some remaining sparks were put out with a portable CO2 extinguisher. The fire is attributed to a high resistance joint failure at a splice fron the containment penetration. Repairs were made and a plan of corrective action for similar cables initiated.

No ACRS action is recommended.

The enclosed material should be retained as part of the permanent record.

(JCM) p omct >

_. ACR S.,....,

..QTUGAL DEE ON!J JCM:bjw sumw >

.#/ 21/.72...

DATE >

..2.....

Form AIC-Ste (Rn. 9-53) AICM 0240

    • o
    • 8-- 38 -M * * *
    • 646

b 0FFICIAL USE ONLY SUFFLEMENT No. 156 CATEGORY B

{ 'h i.y

" ' Cities Unit 2 Continued August 21, 1972 y

-s, 7

'g-

.s M

Valve Malfunction

{.,/

Commonwealth Edison Casesny TWK dated July 28. 1972 reports that 1

the inboard steam supply valve to the isolation cooling system would not close.

{

No ACRS action is recommended.

The enclosed material may be discarded after your review.

]

i (JCW)

{

HMH Valve Malfunction Commonwealth Edison Company letter dated Aurust 3.1972 reports the failure of the inboard primary containment isolation valve in the RCIC system. The failure was found to be a faulty torque limit switch.

The switch was replaced and normal operation restored.

No ACRS action is recommended.

The enclosed material may be discarded after your review.

(JCM) 4

{

Ouad Cities Units 1 & 2 i

HMH Change to Interim Report on Turbine Buildine Floodine Incident ACRS Commonwealth Edison causany latter dated July 24. 1972 describes the changes to the Interim Report already submitted by CE (see CE letter dated July 18, 1972, above).

No ACRS action is recommended.

The enclosed material may be discarded after yonr review.

(JCM)

M Tech Spee Chantes b

ACR8 Commonwealth Edison Company letter dated July 25, 1972 forwards proposed changes to the Technf cal Specifications.

{

5o ACRS action is recommended.

I o m et >

The enciesed material -should be-retained-pending Regulatory Staff ae' tion on the request.

$URNAME>

DATE >

form AIC-Sis (Rev. B-53) AFCM 0240 ENNiNE,5N17s

\\

CITICIAL USE OttLY SUPPLDENT NO.156 CATB00RY 5 fLh >-

Cities Units 1 & 2 continued Angest 21, 1972

  • j pip /

ff:i ~~ N &

[$[ 3l DEL Full Power License. Ramuest for Additional Kafermation AEC letter dated July 26. 1972 requests adC.itional information for the Technical Specifications for operation at 90% and 100%

of rated power. The additional information relates tot 1.

Turbine operation 2.

Radiation detectors 3.

Control rod position indication surveillance 4.

Rod worth minimiser 5.k water haummer prevention 6.

Containment surveillance 7.

Maintenance 8.

Set point changes No ACKS action is recommended.

The enclosed material may be discarded after your review.

(JCD0 -

HMH Modifications as a Result of the Turbine Baseanne Floodine Imeident ACKS Commonwealth Edison Company letter dated July 31. 1972 emhmics the

" Final Report on Condenser Pump Room Modifications for Quad-Cities Units 1 and 2".

The modifications include:

1.

Sealing of f the condenser pit from the condensate pump room.

2.

Enclosing the RHR service water pumps and the diesel generator cooling water pumps in water tight vaults.

Desighhdetails are provided.

i No ACRS action is recommended.

Ths enclosed material should be retained as part of the permanent record.

Aw TWh

+

i' p'

i.

d I

e omct>

i OFF :CiAL USI OhT

$URNAMt>

DATI>

Form AEC 318 tRev. 9-53) AECM 0240 e.o eo-se-sista-:.o-tas

0171 CIA 1. USE ONLY l

{

t SUFFimENT NO.156 CAT 300ItY 5

)

gg i

"' Cities Units 1 6 2 C-_tinued August 21,1972 Q'r BE Cask Dren Accident f

e e

-Ich Edison Company letter dated *--t 1.1972 requests that the due date for the cask drop accident evaluation be l

extended from July 21 to August 25, 1972.

1 No ACRS action is recommended.

1 The enclosed material may be discarded after your review.

(JCN) 4 HMH Diffuser Pipes C-n-1th Edison Commenv lattor dated A=-use 3.1972 reporto that the diffuser pipes into the Mississippi River were put into operation on August 2.1972. Issusace of a 90% of rated power license is requested.

No ACRS action is recommended.

The enclosed material may be discarded after your review.

(KM)

IMH Vacuum Breakers b

ACRS ABC letter dated Anaust 9. 1972 requests additional information regarding t.he suppression ch -har vacuum breakers to the drywell.

No ACRS action is recommended.

The enclosed material may be discarded after your review.

4 M)

I l

orrect >

$URNAME>

DATE >

0FFICIA1. W E.ONLY..

Form AFC-Sin (Rev. 9-53) AECM 0240

    • s F i+6a-a unsas b

j