Text
_ _ - _ _ - _ _ - _ - _ _ _.
l
\\N(*g,,
UNITED STATES
//
.M
' i ' \\,"-
ATOMIC ENERGY COMMISSION l
'4
/ h'-
)*
W ASHINGTON. D.C.
20$45 kk[ig**
December 27, 1972 Dachet Nos. 50-237, 50--249, 50-254 and 50-265 s
Dr. Chester P. Siess Chainmn, Advisory Comittee on Reactor Safe w @
e U. S. Atomic Energy Comission Washington, D. C.
20545
- ar Dr. Siess:
n Sixteen (16) copies of the following am transmitted for the Co =ittee's infarmatlon:
Let ter f rom Commonwealth Edison Company dated December 18, 1972, regarding scram reactivity limitations for Dresden Units 2 and 3 and Quad-Cities Units 1 and 2.
- Sincemly, 1
/
h/
Y
/
Donald J.
. o'. tolt Assistant Director for Operating Beactors Directorate of Licensing Ehclostnes :
As stated f,
8707060455 070610 PDR FOIA "j l THOMAS 87-40 PDR
' i.
j j
b
f $h
- s' OFFICIAL USE ONLY SUPPLEMENT NO. 161 CATEGORY B Dresden Units 2 and 3 January 30, 1973 Quad Cities Units 1 and 2 HE Scram Reactivity Curves DOI Coenonwealth Edison Company letter dated December 18. 1972 ACRS responds to an AEC request to analyze the scram reactivity curves for Dresden Units 2 and 3 and Quad Cities Units 1 and 2.
The limiting scram curve was associated with an end of cycle, full power, all control rods out condition. Apparently Quad Cities 1 and 2 and Dresden 2 cannot operate within the current technical specifications until the end of a cycle.
Apparently Commonwealth Edison Company believes these plants
~
should not operate beyond 7500 IGD /T. Dresden Unit 3 appears to be in better shape for a number of reasons.
A complete evaluation and report is proposed for March 15, 1973.
No ACRS action is recommended.
The enclosed material may be discarded after your review.
(JCM) i 1
1 1
1 I
1 I
Filed:
- 1) Dresden Units 2 & 3
- 2) Quad Cities Units 1 & 2 omer >....ACRS su-c >
. JcM.; bj w..,,.,.
1/30/73 0FF [CIAL USE ONLV em..
.........=....l.
. i..
r-arc-m ix-s.si.4tcr.,om
.... u -i -. s.u.,.~.
_ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ - _. -