Text
-_-
\\-
l-3'[ '\\,b UNITED STATES II [r b d ATOMIC ENERGY COMMISSION f
WASHINGTON, D.C. 20545
%, %,5 eD' RECEIVED October 4, 1972 Docket No. 50-254 L'.S. Aloi.t
.... ~. LOMM.
tDVISORY 0MMl1 TEE ON hEACIC5, SAFEGUARDS Dr. Chester P. Siess Chairman, Advisory Comittee on Reactor Safeguards U. S. Atomic Energy Comission Washington, D. C.
20545
Dear Dr. Siess:
Sixteen (16) copies of the following am transmitted for the
. Comittee's information:
TWX from Commonwealth Edison Company date'd September 29, 1972, reporting an incident regarding the 12th suppression chamber to drywell vacuum breakers.
r l
Sh m4, affolt&
Donald J.
Assistant Dimetor for Operating Beactors Dim otorate of Licensing Ehclosums:
As stated
[ '-
^~'}.
,J\\
@ p' r s
9;.
i g
40 Wg B707070413 870610 PDR FOIA THOMASB7-40 PDR '
O
'0" ' D.
i31 e
-( '.
OITICIAL 064, ONLY SUPPLEMENT NO. 158 CATEGORY B dhsal Cities Unitl October 6,1972-@-
9 01 Vacuum Breakers
. ;b
~
g 3:
ACRS Commonwealth Edison Coinpany TWX dated September 29. 1972 advises that an inspection at Unit I revealed three suppression chasher te drywell vacuum breaker valves lodged open even though tleeir i
remote indicators showed " closed". Modifications are 1eing made to correct this condition.
1 This matter is scheduled for discussion with the Regulatory Staff at the October 1972 ACRS meeting.
The enclosed material should be retained pending completion of the corrective action.
OCM) l l
I I
I ACRS
^
OrtidI4E."USE"Dd"" '
ut >
.10 /6/ 72--
- g i>
....... ~
t
.9 53) AECM 0240 opo so-in-stenH 645-o7s
_.-