Text
_
- . **+,
UNITED STATES f%-
ATOMIC ENERGY COMMISSION Lt OEu -
..s,~ oro~.o.c......
l:
4,LQ3 -
- .. y. i.c 5
%ns e December 27, 1972 I 34 Docket No. 50-254
.i, " " 2' l o-
- ii1.
i I EE O!1 -
' 03 Dr. Chester P. Siess Chairman, Advisory Comittee on Reactor Safeguards U. S. Atomic Ehergy Conmission Washington, D. C.
20545
Dear Dr. Siess:
Sixteen (16) copies of the following am transmitted for the Comittee's information:
Letter from Commonwealth Edison Company dated December 4, 1972, regarding the Quad-Cities Unit 1 jet pump instru-J ment line failure.
Letter from Commonwealth Edison Company dated December 5, 1972, regarding the drift of two primary containment iso-lation system instruments at Quad-Cities Unit 1.
Sincem ly, 1
1 Asf h/"
/
Donald J.
o olt Assistant Dimetor for Operating Beactors Dimetorate of Licensing
Enclosures:
As stated
)0
,g la Q.~
l
i.
\\$
{
i o
m R A O L. M L <. 2; a (Ms B707070167 870610 PDR FOIA THOMAS 87-40 PDR
\\
+
Luiis.
...