Application for Amend to License DPR-34,changing Plant Protective Sys Trip Setpoints & Surveillance Requirements
ML20210S329
Person / Time
Site: Fort Saint Vrain 
Issue date: 05/15/1986
From: Odonnell B, Thompson R, Walker R
KELLY, STANSFIELD & O'DONNELL, PUBLIC SERVICE CO. OF COLORADO
To:
Shared Package
ML20210S328 List:
References
TAC-47416, NUDOCS 8605210172
Download: ML20210S329 (5)


Text

c-.

o-S BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of the Facility Operating License)

)

of

)

)

PUBLIC SERVICE COMPANY OF COLORADO

)

Application for Amendment to Appendix A of Facility Operating License License No. DPR-34 0F THE PUBLIC SERVICE COMPANY OF COLORADO FOR THE FORT ST. VRAIN NUCLEAR GENERATING STATION This application for Amendment to Appendix A of Facility Operating License, License No. DPR-34, is submitted for NRC review and approval.

Respectfully submitted, PUBLIC SERVICE COMPANY OF COLORADO By R. F. Walker, President KELLY, STANSFIELD & O'DONNELL Bryant O'Donnell Robert E. Thompson Public Service Company Building Denver, Colorado 80202

~

Attorneys for Applicant k

kDO P

r

-V h

O ATTACHMENT 1

SUMMARY

OF PROPOSED CHANGES

. g Attachmment 1 to P-86279

SUMMARY

OF PROPOSED CHANGES LCCTION DESCRIPTION LSSS 3.3

1. Page 3.3-1.

Definitions are added for Trip Setpoint and Allowable Value.

2. Pages 3.3-2a, 26, 2c, 3a and 3b replace old pages 3.3-2 and 3.3-3.

A Trip Setpoint and Allowable Value are now specified for each parameter and two curves are used with Table 3.3-1.

Basis for LSSS 3.3

1. Pages 3.3-4 through 3.3-9 replace old pages 3.3-4 through 3.3-8.

The new basis discusses the methodology for determining Trip Setpoint and Allowable Value and then describes the basis for each limiting safety system parameter.

LCO 4.4-1

1. Page 4.4-1.

Definitions added for Trip Setpoint and Allowable Value.

Two para-graphs of old page moved to next page.

2. Page 4.4-2.

The paragraph on Table 4.4-3 expanded and page reformatted.

3. Tables 4.4-1 through 4.4-4.

The tables were reformatted to provide for a Trip Setpoint and Allowable Value to replace the Trip Setting.

Each table was split into Part I containing Trip Setpoint and Allowable Values for each parameter and a Part 2 containing Minimum Operable Channels, Minimum Degree of Redundancy and Permissible Bypass Conditions. Part 2 follows Part 1 for each table.

l l

4. Old pages 4.4-3 through 4.4-7 replaced l

by pages 4.4-3a, 3b, 3c, 4a, 4b, 4c, 4d, Sa, 5b, Sc, 6a, 6b and 4.4-7.

Note that contents of old page 4.4-7 l

moved to new page 4.4-6.

New page 4.4-7 intentionally left blank.

I l

t L

3 s

5. Page 4.4-8.

Notes for Tables 4.4-1 through 4.4-4.

Note (a) deleted as Table 4.4-1 line items 3a. and 3b. refer operator to Table 3.3-1.

Note (d) deleted as the Trip Setpoint and Allowable Value in new tables provide specific criteria for the Plant Electrical System - Loss parameter. Note (h) in existing license split into two separate notes (hl) and (h2) to more correctly reflect applicable permissible bypass conditions for the different types of moisture monitors.

Basis for LCO 4.4-1

1. Pages 4.4-10 through 4.4-13 of existing license replaced by new pages 4.4-10, 10a, 10b, 10c, 11, lla, lib, 12, 12a, 12b and 4.4-13.

The new basis is more des-criptive than the original basis.

W-h ATTACHMENT 2 0F P-86279 PROPOSED CHANGES TO LSSS 3.3 AND LCO 4.4.1 0F THE FSV TECHNICAL SPECIFICATIONS

.