MONTHYEARML19347C0651980-10-0101 October 1980 Forwards Application for Amend of License DPR-34,changing Tech Specs 2.0 & Tables 3.3.1 & 4.4-1 Through 4.4-4 to Revise Instrument Setpoints Project stage: Request ML19347C0701980-10-0101 October 1980 Application for Amend of License DPR-34,changing Tech Specs 2.0 & Tables 3.3.1 & 4.4-1 Through 4.4.4 to Revise Instrument Setpoints Project stage: Request ML19347C0731980-10-0101 October 1980 Proposed Changes to Tech Specs 2.0 & Tables 3.3.1 & 4.4-1 Through 4.4-4,revising Instrument Setpoints.Supporting Documentation Encl Project stage: Request ML20028E3271983-01-14014 January 1983 Requests Technical Assistance W/Proposed Tech Spec Setpoint Revs Requested by Util.Region Will Provide Assistance,Act as Contact Between NRR & Util & Process & Issue Change.Nrr Will Review Request & Issue Ser.W/O Encl Project stage: Other ML20072P1341983-07-11011 July 1983 Proposed Tech Spec Changes Assuring Operability of Plant Protective Sys Limiting Conditions for Operation Defining Trip Setpoint Operability Project stage: Other ML20087E6151984-02-17017 February 1984 Rev a to Work Spec WS-93-0004, Reevaluation of Plant Protection Sys Setpoints Project stage: Other ML20087E5941984-03-0909 March 1984 Forwards Rev a to Work Spec WS-93-0004, Reevaluation of Plant Protection Sys Setpoints, as Result of 831027 Agreement to Revise Previous Application for Amend to Tech Specs Project stage: Request ML20112J0981985-03-18018 March 1985 Advises That Setpoint Reevaluation Program & Tech Spec Update Program Adopted.Proposed Amend to License DPR-34 for Plant Protective Sys Setpoints Will Be Submitted on or Before 850501 Project stage: Other ML20127P1071985-06-21021 June 1985 Advises That Util 850607 Submittal Re Draft Tech Specs for Control Rod Operability Acceptable Provided That Listed Changes Made.Confirmatory Submittal by Licensee of Revised Draft Tech Specs Should Be Provided Prior to Restart Project stage: Request ML20209F4231985-06-21021 June 1985 Forwards Application for Amend to License DPR-34,revising Tech Specs Re Limiting Conditions for Operation of Protective Sys Instrument Setpoints & Allowable Values Project stage: Request ML20209F4401985-06-21021 June 1985 Application for Amend to License DPR-34,revising Tech Specs Re Limiting Conditions for Operation of Protective Sys Instrument Setpoints & Allowable Values.Fee Paid Project stage: Request ML20209F4461985-06-21021 June 1985 Proposed Tech Specs Re Limiting Conditions for Operation of Protective Sys Instrument Setpoints & Allowable Values Project stage: Other ML20136F6651985-12-31031 December 1985 Informs of Continuation of Reviews Re Allowable Value & Trip Setpoint.Tech Spec Changes Submitted in .After Acceptable Margin Established Analyses Will Be Performed. Tech Spec Change Request Will Be Submitted by 860401 Project stage: Other ML20137P8021986-01-24024 January 1986 Forwards Draft Safety Evaluation Re 850621 Request to Change Tech Specs on Plant Protection Sys Instrumentation Setpoints.Resubmittal of Proposed Tech Specs to Reflect Acceptable Setpoints Requested within 45 Days Project stage: Draft Approval ML20140F8271986-03-25025 March 1986 Ack Receipt of NRC Re Proposed Tech Spec Change Request for Plant Protective Sys Trip Setpoints.Reevaluation of Basis & Analyses for Setpoint Justification for Fixed Feedwater Flow Low Parameter in Progress Project stage: Request ML20155E8421986-04-14014 April 1986 Advises That Addl Time Required to Fully Integrate Tech Spec Changes Re Plant Protection Sys Setpoints Into Existing Format.Tech Spec Amend Request Will Be Submitted by 860516 Project stage: Other ML20210S3261986-05-15015 May 1986 Forwards Application for Amend to License DPR-34,changing Plant Protective Sys Trip Setpoints & Surveillance Requirements.Summary of Proposed Changes & Comments on Draft SER Also Encl.Fee Paid Project stage: Draft Request ML20210S3291986-05-15015 May 1986 Application for Amend to License DPR-34,changing Plant Protective Sys Trip Setpoints & Surveillance Requirements Project stage: Request ML20210S4191986-05-15015 May 1986 Proposed Tech Specs,Changing Plant Protective Sys Trip Setpoints & Surveillance Requirements Project stage: Other ML20211P8291986-07-18018 July 1986 Ack Receipt of Re Plant Protective Sys Setpoints. Item Under Review w/860930 Target Completion Date Project stage: Other ML20211E0111986-10-16016 October 1986 Forwards Request for Addl Info Re NRC Review of Util Info on Plant Protective Sys Trip Setpoints & Surveillance Requirements Against Draft Safety Evaluation Forwarded on 860124 Project stage: Draft Approval ML20214P5751986-11-26026 November 1986 Recommends That Util Propose Tech Specs Based on Annual Allowable Values Re Plant Protective Sys Trip Setpoints. Response Requested within 60 Days of Ltr Date Project stage: Other ML20210B0611987-04-27027 April 1987 Requests That Submittal of Plant Protective Sys Setpoint Info Be Deferred Until 870831,in Response to NRC . Delay Due to Recent Efforts Focusing on Plant Restart Issues Project stage: Other ML20235A9971987-08-28028 August 1987 Forwards Response to NRC 861016 Request for Addl Info on Util 850621 & 860515 Requests for Amend to Tech Specs Re Trip Setpoints & Operating Requirements.Proposed Tech Specs Also Encl Project stage: Request ML20235B0091987-08-28028 August 1987 Proposed Tech Specs Re Trip Setpoints & Operating Requirements Project stage: Other ML20235R4161987-10-31031 October 1987 Draft Eg&G Technical Evaluation Rept for Plant Protective Sys Trip Setpoints for Fort St Vrain Nuclear Generating Station Project stage: Draft Other ML20235V8871987-10-31031 October 1987 Draft Plant Protective Sys Trip Setpoints for Fort St Vrain Nuclear Generating Station, Technical Evaluation Rept Project stage: Draft Other ML20236V3191987-10-31031 October 1987 Draft Plant Protective Sys Trip Setpoints for Fort St Vrain Nuclear Generating Station, Technical Evaluation Rept Project stage: Draft Other ML20236V2941987-11-25025 November 1987 Forwards Draft EGG-NTA-7289, Plant Protective Sys Trip Setpoints for Fort St Vrain Nuclear Generating Station, Technical Evaluation Rept.Discussion of Encl Draft W/Nrc at 871202 Meeting Proposed ML20237D6921987-12-15015 December 1987 Summary of 871203 Meeting W/Util & Inel Re Protective Sys Setpoints in Tech Specs.List of Meeting Attendees Encl Project stage: Meeting ML20149M2731988-02-0808 February 1988 Forwards Application for Amend to License DPR-34,revising Tech Specs on Plant Protective Sys Trip Setpoints & Operating Requirements Project stage: Request ML20149M2851988-02-0808 February 1988 Application for Amend to License DPR-34,revising Tech Specs Re Plant Protective Sys Trip Setpoints & Operating Requirements Project stage: Request ML20149M2901988-02-0808 February 1988 Proposed Tech Spec Re Plant Protective Sys Trip Setpoint & Operating Requirements Project stage: Other ML20151B0031988-03-31031 March 1988 Technical Evaluation Rept for Plant Protective Sys Trip Setpoints for Fort St Vrain Nuclear Generating Station, Informal Rept Project stage: Other ML20154B8061988-04-28028 April 1988 Forwards Notice of Consideration of Issuance of Amend to License DPR-34 & Opportunity for Hearing Re 880208 Application Concerning Setpoints for Plant Protective Sys Project stage: Other ML20154B8131988-04-28028 April 1988 Notice of Consideration of Issuance of Amend to License DPR-34 & Opportunity for Hearing.Amend Modifies Setpoints Used in Plant Protective Sys Project stage: Other ML20195B4981988-06-0303 June 1988 Forwards Notice of Environ Assessment & Finding of No Significant Impact Re Util 880208 Application Concerning Setpoints for Plant Protective Sys Project stage: Other ML20195B5481988-06-0303 June 1988 Notice of Environ Assessment & Finding of No Significant Impact Re Util 880208 Proposed Revised Setpoints for Plant Protective Sys to Allow for Administrative Errors.Commission Has Decided Not to Prepare EIS Project stage: Other ML20151A9881988-06-20020 June 1988 Forwards Amend 60 to License DPR-34,safety Evaluation & Technical Evaluation Rept EGG-NTA-7289.Amend Revises Setpoints for Plant Protective Sys to Allow for Instrumentation Error Project stage: Approval 1986-04-14
[Table View] |
Text
-
Mn N-O Public Service ~
=A..
?i?n$rTc$ao201ano RO WILLIAMS, JR.
NLIA oi[bDONS February 8, 1988 Fort St. Vrain Unit No. 1 P-88025 U. S. Nuclear Regulatory Commissica ATTN: Document Control Desk Washington, D.C.
20555 Attention: Mr. Jose A. Calvo Director, Project Directorate IV Docket No. 50-267
SUBJECT:
Technical Specification Change Request to the Plant Protective System Trip Setpoints
REFERENCE:
See Enclosure 1
Dear Mr. Calvo:
Public Service Company of Colorado (PSC) submitted by letters dated June 21, 1985 (Reference 1), May 15, 1986 (Reference 2), and August 28, 1987 (Reference 3) an amendment request to the Fort St. Vrain (FSV) Technical Specifications on the Plant Protective System (PPS)
Trip Setpoints and operating requirements.
The latter amendment request was based on NRC written direction submitted in References 4 and 5.
The NRC, by letter dated November 25,1987 (Reference 6), submitted a Draft Technical Evaluation Report prepared by their contract reviewer on the sutoittal of Reference 3.
On December 3, 1987 a meeting between members of the PSC staff, the NRC and the Idaho National Engineering Laboratory (EG&G Idaho) was held to discuss Reference 3 and 6.
PSC is hereby submitting a revised Amendment request to the Plant Protective System Instrumentation Technical Specification, based on the resolutions reached in the December 3, 1987 PSC/NRC meeting.
This Amendment request contains the following Attachments:
8802250455 080200 PDR ADOCK 05000267 il P
PDR
\\
Y P-88025 Page 2 l
February 8, 1988 1
' : PSC response to the Draft Technical Evaluation Report concerning the Plant Protection System setpoints for Fort St. Vrain.
. : Proposed Amendment Request to the FSV PPS Technical Specification, b : Significant Hazards Consideration.
At the December 3, 1987 NRC/PSC meeting, a discussion was held on the i
applicability of addressing the safety valves and rupture discs specified in the LSSS 3.3 Technical Specification section with the Standard Technical Specification format for "<" or ">" specified Trip Setpoints and Allowable Values.
Since valves and rupture discs are not directly applicable to the applied ISA S67.04-1982 methodology l
for instrumentation, the proposed Trip Setpoints and Allowable Values are based on the existing FSV Technical Specification tolerances.
2 I
i The NRC staff upon further review notified PSC in a telecon that the
]
applicable Trip Setpoints specified with a
'plus' and
'minus' j
tolerance and associated Allowable Value based on the
'plus' tolerance was acceptable as proposed in Reference 3.
The NRC staff requested that the significance of the 'minus' tolerance value be i
discussed in the Basis and that the minus tolerance not be included in the Allowable Value column, since only the plus tolerance corresponds to a Safety Limit.
)
PSC would like to note that while the existing Technical
)
Specifications specified tolerances apply to the "as found" condition 3
and therefore the basis for reportability, the proposed Technical i
Specifications for the safety valves and rupture discs (LSSS 3.3) associated "minus" tolerance (with no corresponding Allowable Value) does not have this provision. The reportability requirements will r
still exist shoulti the "as found" value exceed the 'plus' tolerance i
which is the specified Allowable Value.
The License Amendment Fee of $150.00 was submitted in the original Amendment Request dated June 21, 1985 (Reference 1).
t A 90 day period after approval of these revisions by the Commission is requested before the revised sections are incorporated into the i
FSV Technical Specifications. The 90 day period is required by PSC I
to revise the applicable procedures, computer software, Plant Protective System daily log sheets, and the Technical Spt.cification j
Compliance Log. This time is also required to retrain all licensed i
persennel.
a
.)
i 4
P-88025 Page 3 February 8, 1988 Should you have any questions concerning this matter, please contact Mr. M. H. Holmes at (303) 480-6960.
Very truly yours, s
/ //
d
. y Kitths/
R. O. Williams, Jr.
Vice President, Nuclear Operations R0W/JS:dd Attachments cc: Albert J. Hazie Colorado Department of Health Regional Administrator, Region IV Attention: Mr. T. F. Wetterman, Chief Project Section B Mr. R. E. Farrell Senior Resident Inspector
P-88025 Page 4 February 8, 1988 1)
PSC Letter Lee to Johnson, dated June 21,1985(P-85214) 2)
PSC Letter Walker to Berkow, dated May 15, 1986 (P-86279) 3)
PSC Letter Williams to Calvo, dated August 28, 1987 (P-87278) 4)
NRC Letter Heitner to Williams, dated October 16, 1986 (G-86545) 5)
NRC Letter Heitner to Williams, dated November 26,1986(G-86624) 6)
NRC Letter Heitner to Williams, dated November 25,1987(G-87422) 4 t
i
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION in the Matter
)
)
Public Service Company of Colorado
)
Docket No. 50-267 Fort St. Vrain Unit No. 1
)
AFFIDAVIT R.
O.
- Williams, Jr., being first duly sworn, deposes and says:
That he is Vice President, Nuclear Operations, of Public Service Company of Colorado, the Licensee herein, that he has read the foregoing information and knows the contents thereof, and that the statements and matters set forth therein are true and correct to the best of his knowledge, information and belief, tO tl R. O. Williams, Jr.'
Vice President Nuclear Operations STATE OF de/nru/r'
)
)
COUNTY OF fff,m n /
)
Subscribed and sworn)to before me, a Notary Public on this 9 '3 day of 6 /wam.
, 1988.
J n sulk)I $$$$ltlWft ires' U$9$glNN)hinll4 &tb t4)tanftw, $tN My commission expires d/mn46 jf
,198f.