Dear Ms. Stephens:
SUBJECT:
RIV-85-A-0013 This refers to our letter to you dated February 4,1985, in which we requested that you contact us and provide additional information regarding your concerns related to construction activities at Kansas Gas and Electric Company's Wolf Creek Generating Station. A general discussion had taken place with Mr. L. E.
Martin of this office on January 23, 1985, prior to the sending of the mentioned letter. The conversation with Mr. Martin was in regard to your previous contact with NRC.
In that you have not contacted us and provided the additional information we-requested, the Regional Staff plans no further action regarding this matter. We did, however, alert our inspectors to your general concerns so that they could pay particular attention to those areas during their routine inspections.
Should you have any questions regarding our disposition of +% ' matter, please call me collect at (817) 860-8100.
If you should call and I am not available, please leave a messege and I will return your call.
Sincerely, T. A. Nash i
i Investigations / Allegations eg62pg6860618 Coordinator, Region IV.
l STEPHEN 85-594 PDR g
Y S W AN
- P.D.%p4zt' h - p W
.OM.
En L-9/6fts-x.p.c w L n '2 % -
B ~M
<L,s k -
~ '
" L -
- E d-IQ
1
'.C CORRECTIch 0F TESTS (CERTIFICATION)
BETWEEN REVISIOhS QA has come up with a way for us to adjust certification tests that are incorrect while we are in the process of reachirg full revision status on all certification.
If you have. just giyen a test,_ and in the evaluation.
1..
stage you find a, question to be incorrect or the answer (fo'r any reason) then you will prepare key to be ' incorrect a meno addressed.to me giving the following information:
Name of the Examination with Rev. number.
a.
Name of' the individ'ual taking the 'tes't'
~
b.
c.' List the question (s) number with a brief statement which speaks to why.the question (s) are not any good. i.e. procedure revision, "out of date material, ho answer. choice,..etc.
d.
For each item in c above state you action taken, i.e. "gave credit for the question due to prouedure revision" or "because answer key is wrong" etc.
Af ter completion of No.1 above. adjust the grade accordingly and send me the memo fastened to. the individual's comple ted tact.
Be sure to ad the grade on a redistribution of good questions /100%.just Should you find prior to giving a certification exam.
2.that a question (s) in incorrect you may eliminate the The question (s) by following the process in No. 1 above.
the individual's exception is that you do not need to include name.That allows you to give the test excluding those bad
~
questions you have identified.
Readjust the remaining Give the test, grade it good questio'ns on the 100% scale..
and send it to me with the meno attached..Thereafter, anyone who takes the same examination do'the same thing as identified in no.1 above. -
IF YOU ADJUST A TEST IN THE ABOVE WAY(S) THEN IMMEDIATELY BEGIN A REVISION PROCESS FOR THE AFFECTED TESTS.
Wf' qulp 1
~
(1)(jb v
0 Qv
/
v (f
X' 3-to s ti2.;ap
DAMID INT E R.O F FIC E CO M M U NIC ATIO N se a nnrEnhADOMAI.
c.,
sus (n e ni D ATE:
January 27, 1983 TO: Lloyd Gladman FROM:
W.S. Lockwood Level II Coatings Certification Exam
SUBJECT:
While grading a Level II Coatings certification Exam ' yesterday'I noted questions 57, and 71-100 (4 questions), were no longer valid due to Procedure Revision - Revision 8 to QCP-V-100 approved 12-15-82.
The exam was KG&E approved 7-8-82.
If the exam is graded per the approved answer sheet the individual who is being tested for re-certification will not recieve a passing grade and his present certification shall It should be noted that the person tested missed only expire 1-28-83.
one of the remaining 69 questions and he is the Lead Coatings Inspector.
In as much as KG&E has revision control which means no additions, deletions or changes without their approval I must grade this persons test to the approved answer sheet, give him a failing grade, and retest This him after 16 working days and an appropriate training program.
course of action is the only approved procedure I may follow per AP-VI-01.
Please advise me as soon as possible as to any alternative approved grading procedure.
/W
/ 0~
M S. fockwood t
r' Ar m e w t O) 3 -/ d 7 eR-ILl
@ML INT ER-O F FIC E CO M M U NIC ATIO N ca amrE n.unomas.
s.,o ga n. s.rst DATE:
TO:
0.L. Gladman January 28, 1983 FROM:
L.D. Bryant Out of Date Certification Exams and/or questions
SUBJECT:
When certification Examinations or individual examination questions become outdated due to procedure revisions, the question (s) or the examination shall be corrected, brought up-to-date and used while waiting for client approval of forth coming revision.
Submission of a new revision should be undertaken within a week (7 working days) after discrepancies have been determined.
Notification must be given to the Project Quality Manager prior to implementing the provisions of this memo.
W. ~ W
$wd//;flrf 4.,arry D. Bfyant Project Qua;ity Manager LDB/mls e,
G t
9 e
e 4
=
8-/05 62-\\h g
j t m.;.d O
(
U $- /ce f(ass}
o M
w
- o
.v.f~.h.va.T.i.7..s_,.
S. F. /M. i. m.M._./..
og 5'l~b$
~
Tr% bed h [ht l'e' c ev s's b e nn..< of / o kf ku
- C yn
/;. (/
,e
'e[s p
n.: s q 71, n, w s,.
-r J,~.,,.s. C a, ~ p n s:sg,,
f kt syrofsw7e '.}l'YC :
Ar<<!,9/ur.1E #7c ' c f 5/9 T
i c' g
......i_._..._..
re..
_.. u.;n r.
o Bill - you go ahead and assign the grade based upon the elimination g
of the above oited questions from the test taken by Mr. McMoy.
g p
This applies only in this specific case.
Future cases will be handlod in the same way on an individual basis.
t Y
r
(\\
11 i(t 1r QJ AIGO bN AP E7IM fOHM p
.f0P COPY FOR RE'FERENCE
~~'
. g.g g g ~ ~ ~ ~ ~
NO. 45001250/CTN 45002 50!PKG l
e I
.