MONTHYEARML20217A9811999-10-30030 October 1999 Forwards Sept 1999 Performance Indicator Data Rept for Revised Reactor Oversight Process Pilot Program.Rept Includes Data Through Aug 1999 (two-thirds of 3rd Quarter of 1999) for 13 Units at 9 Pilot Sites ML18107A5021999-08-31031 August 1999 Notification of 990915 Meeting with Licensee in Bethesda,Md to Discuss Conduct of Three Baseline Pilot Fire Protection Insp & Application of New Fire Protection Insp Findings Significance Determination Process ML20211H4441999-08-27027 August 1999 Notification of Significant Meeting with Util on 990916 & 17 in Arlington,Tx to Improve Utility & NRC Understanding of Industry & Regulatory Perspectives on Current Issues ML18107A4841999-08-23023 August 1999 Notification of 990915 Meeting with Industry & Util in Rockville,Md to Discuss Conduct of 3 Baseline Pilot Fire Protection Insp & Application of New Fire Protection Insp Findings Significance Determination Process ML18066A6211999-08-17017 August 1999 Notification of 990913-14 Meeting with Util in Kansas City, Mo Re NRC & USA Joint Sponsorship of Licensing Workshop with Goals of Improving Quality of Licensing Submittals & Improving Licensing Interface Between Licensees & NRC ML20210J9721999-08-0202 August 1999 Notification of 990817 Meeting with Util in Rockville,Md to Discuss Util Radiological Consequences Improvement Program Implementation,Program Impact on Util Response to GL 99-02 & Alternate Course of Action to Requirements Discussed in GL ML20210F6981999-07-27027 July 1999 Discusses 990430 Request for Waiver of 10CFR170 Fees for Certain Insp Efforts Re NRR Pilot Regulatory Oversight Program.Determined That Thirteen Plants in Pilot Program Will Be Exempted from 10CFR170 Fees for Insp Efforts ML20196J5661999-07-0101 July 1999 Notification of 990714 Meeting with OPPD & CE in Rockville, Maryland to Discuss Staff Concerns with OPPD PTLR Submittal & CEOG Topical Rept CE NPSD-683 ML16342A8471999-06-29029 June 1999 Notification of 990720 & 21 Meetings with Utils in Arlington,Tx to Discuss risk-informed Initiatives & Topics of Interest ML20196H8491999-06-28028 June 1999 Forwards June 1999 Performance Indicator (PI) Data Rept for Revised Reactor Oversight Process Pilot Program.Rept Constitutes Second Monthly PI Data Submittal from Pilot Plant Licensees,Which Includes Data Through May 1999 ML20207G4241999-06-0202 June 1999 Notification of 990630 Meeting with Util in Fort Calhoun, Nebraska to Discuss Miscellaneous Management Topics & Plant Status ML20207D3251999-05-28028 May 1999 Notification of 990617 Meeting with Util in Blair,Nebraska to Inform Public of NRC Plans for Implementing Risk Informed Baseline Insp Pilot Program at Fort Calhoun Station ML20210F7021999-04-30030 April 1999 Requests Waiver of Fees for Thirteen Dockets That Compromise Plant Population for NRR Pilot Regulatory Oversight Program. Purposes of Pilot Program Described in Commission Papers SECY-99-007 & SECY-99-007A ML20205N1741999-04-12012 April 1999 Notification of Revised Licensee Meeting with Util on 990419 to Discuss Results of PPR Completed 990211.New Location of Meeting Will Be in Visiting Inspector room,2nd Floor at Fort Calhoun Station,Admin Bldg,Fort Calhoun,Ne ML20204J0221999-03-19019 March 1999 Notification of 990419 Meeting with Omaha Public Power District to Discuss Results of Plant Performance Review Completed on 990211 ML20207L7181999-03-0202 March 1999 Notification of 990318 Meeting with OPPD in Rockville, Maryland to Discuss OPPD NPSH Calculation Used to Support Fort Calhoun Station USAR Change to Take Credit for Containment Overpressure or Sump Subcooling ML20198M3071998-12-31031 December 1998 Notification of 990114 Meeting with Util in Rockville,Md to Discuss Fort Calhoun Station Radiological Consequences Improvement Program Issues & Implementation ML20196D3341998-11-24024 November 1998 Notification of 981204 Meeting with Util in Rockville,Md to Discuss Fort Calhoun Station Radiological Consequences Improvement Program Issues & Implementation ML20195B4071998-11-0404 November 1998 Notification of 981130 Licensee Meeting with Util in Arlington,Tx to Discuss Recent License Exam Results ML20154L3781998-10-15015 October 1998 Notification of 981020 Meeting W/Util to Discuss Regional Administrator OPPD Common Cause Analysis ML20154C2211998-10-0101 October 1998 Notification of Licensee Meeting with Util on 981015 in Arlington,Tx to Discuss Maint & Engineering Issues Related to turbine-driven & diesel-driven Auxiliary Feedwater Pumps Overspeed Events ML20153D7441998-09-21021 September 1998 Notification of 981006 Meeting with Util in Fort Calhoun,Ne to Discuss Common Cause Analysis ML20236X5111998-08-0606 August 1998 Notification of 980819 Meeting W/Omaha Public Power District in Rockville,Md to Discuss Fort Calhoun Station Refueling Outage Accomplishments,Challenges & Emerging Issues ML20236M9621998-07-0808 July 1998 Notification of 980723 Meeting W/Util in Arlington,Tx to Discuss Licensee Performance ML16342E1431998-06-22022 June 1998 Notification of 980722-24 Meeting W/Utils in Arlington,Texas to Conduct Examination Writing Workshop ML20249C6141998-06-22022 June 1998 Revised Notification of Licensee Meeting W/Util on 980710 to Discuss Switchyard Mods at Fort Calhoun Station ML20248L2961998-06-0505 June 1998 Notification of Significant Licensee Meeting W/Util on 980710 to Discuss Switchyard Mods at Fort Calhoun Station ML20247M1631998-05-14014 May 1998 Refers to GL 92-01,Rev 1,Supplement 1, Rv Structural Integrity, Issued in May 1995.RAI Re Plant 971013 Submittal of Revised Rv Weld Chemistry Valves Encl.Response Requested within 90 Days of Receipt of Ltr ML20217K3251998-04-28028 April 1998 Notification of 980505 Meeting W/Nebraska Public Power District in Arlington,Tx to Discuss Current Operations Dept Issues ML20203F7461998-02-23023 February 1998 Notification of 980309 Meeting W/Util in Arlington,Tx to Discuss Switchyard Mods at FCS ML20198E2091997-12-30030 December 1997 Requests Attached 4 Pages Be Placed in Docket File & Pdr. Suppl to 961120 Application to Amend Fort Calhoun License & Tss.Document Faxed Concurrence of License Commitment Re Relocation of Certain TS Requirements ML20199H2531997-11-24024 November 1997 Forwards Signed Original of Order Prohibiting Involvement in NRC-licensed Activities (Effective Immediately) Fs Bandy,For Transmittal to Ofc of Fr for Publication.W/O Encl ML20198Q2461997-10-31031 October 1997 Notification of 971113 Meeting W/Util in Rockville,Md to Discuss Issues Related to FCS Fire Protection Improvements, USAR Verification & OPPD Proposal for Submitting Substantial TS Changes in Lieu of Coverting to Std TS ML20217B4311997-09-22022 September 1997 Notification of 971007 Predecisional Enforcement Conference W/Util in Arlington,Tx to Discuss Disabling of Containment Spray Sys ML20210N8801997-08-21021 August 1997 Notification of Licensee Meeting W/Util on 970924 in Blair, Ne to Discuss Systematic Assessment of Licensee Performance. Meeting Open to Attendance by Members of General Public ML20217M0521997-08-14014 August 1997 Informs That Operator Licensing Exams Administered on 970414-0506 at Fort Calhoun,Unit 1.Listed Info for Processing Through Nudocs & Distribution to NRC Staff Including NRC PDR Also Encl ML20210J0951997-08-0505 August 1997 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam at Facility on 971008.Requests That Listing of Names of Candidates for Exam Be Submitted to Listed Individuals by 970908 ML20141G9081997-07-0707 July 1997 Notification of 970721 Predecisional Enforcement Conference in Arlington,Texas to Discuss Apparent Violation of 10CFR50.65 Related to 970421 Steamline Rupture Event ML16342D6551997-05-16016 May 1997 Notification of Licensee Meeting W/Util on 970529-30 to Conduct Workshop on Test Item & Exam Development to Meet Agency Expectations of Facility licensee-developed Initial Licensing Exam.Proposed Agenda Encl ML20138E3261997-04-29029 April 1997 Notification of Significant Licensee Meeting W/Util on 970505 to Discuss Steam Line Break,Root Cause Analysis & Corrective Actions ML20134P2231997-02-20020 February 1997 Discusses Ti 2515/122 Evaluation or Rosemount Pressure Transmitter Performance & Licensee Enhanced Surveillance Programs multi-plant Action B-122 ML16343A6961997-02-18018 February 1997 Notification of Licensee Meeting W/Util on 970225 in Arlington,Tx to Discuss Results of Region IV Util Group Review of NRC Enforcement Policy & Nonescalated Enforcement Process ML20133H7781997-01-14014 January 1997 Notification of Significant Licensee Meeting W/Util on 970129 in Arlington,Tx to Discuss Issues Re Post-Accident Sample Sys ML20129E7041995-12-29029 December 1995 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal) for Tests Administered on 951204-08 ML20136A7871995-12-19019 December 1995 Partially Withheld Memo Discussing Petition Filed by Jf Doherty Requesting Six Plant Reactors Be Immediately Shutdown & Directors Decision 95-22 Which Denies Request ML16342D0891995-10-10010 October 1995 Notification of Significant Licensee Meeting W/Listed Utils on 951109 to Discuss Pressure Locking & Thermal Binding of power-operated Gate Valves (GL 95-07).Meeting Agenda Encl ML16342D0301995-08-23023 August 1995 Notification of Significant Licensee Meeting W/Util on 950907 to Discuss Pilot Exam Development Program ML20059H8831994-01-24024 January 1994 Submits Daily Highlight Re 940127 Meeting W/Util in Rockville,Md to Discuss Plant Plans for Future Amends & Current Licensing Status ML20058K1231993-12-0202 December 1993 Forwards CS Wingo of FEMA Transmitting Final Exercise Rept for 930629 Exercise of Offsite Radiological Emergency Response Plans for Plant.Eight Deficiencies Noted During Exercise ML20057B3401993-09-13013 September 1993 Requests That NRR Provide Review of Concern Re Licensee TS Action Statement for Inoperable Channel for SIRWT Level to Determine If It Is Appropriate to Request Change Be Initiated to Plant TS 1999-08-31
[Table view] Category:MEMORANDUMS-CORRESPONDENCE
MONTHYEARML20217A9811999-10-30030 October 1999 Forwards Sept 1999 Performance Indicator Data Rept for Revised Reactor Oversight Process Pilot Program.Rept Includes Data Through Aug 1999 (two-thirds of 3rd Quarter of 1999) for 13 Units at 9 Pilot Sites ML18107A5021999-08-31031 August 1999 Notification of 990915 Meeting with Licensee in Bethesda,Md to Discuss Conduct of Three Baseline Pilot Fire Protection Insp & Application of New Fire Protection Insp Findings Significance Determination Process ML20211H4441999-08-27027 August 1999 Notification of Significant Meeting with Util on 990916 & 17 in Arlington,Tx to Improve Utility & NRC Understanding of Industry & Regulatory Perspectives on Current Issues ML18107A4841999-08-23023 August 1999 Notification of 990915 Meeting with Industry & Util in Rockville,Md to Discuss Conduct of 3 Baseline Pilot Fire Protection Insp & Application of New Fire Protection Insp Findings Significance Determination Process ML18066A6211999-08-17017 August 1999 Notification of 990913-14 Meeting with Util in Kansas City, Mo Re NRC & USA Joint Sponsorship of Licensing Workshop with Goals of Improving Quality of Licensing Submittals & Improving Licensing Interface Between Licensees & NRC ML20210J9721999-08-0202 August 1999 Notification of 990817 Meeting with Util in Rockville,Md to Discuss Util Radiological Consequences Improvement Program Implementation,Program Impact on Util Response to GL 99-02 & Alternate Course of Action to Requirements Discussed in GL ML20210F6981999-07-27027 July 1999 Discusses 990430 Request for Waiver of 10CFR170 Fees for Certain Insp Efforts Re NRR Pilot Regulatory Oversight Program.Determined That Thirteen Plants in Pilot Program Will Be Exempted from 10CFR170 Fees for Insp Efforts ML20196J5661999-07-0101 July 1999 Notification of 990714 Meeting with OPPD & CE in Rockville, Maryland to Discuss Staff Concerns with OPPD PTLR Submittal & CEOG Topical Rept CE NPSD-683 ML16342A8471999-06-29029 June 1999 Notification of 990720 & 21 Meetings with Utils in Arlington,Tx to Discuss risk-informed Initiatives & Topics of Interest ML20196H8491999-06-28028 June 1999 Forwards June 1999 Performance Indicator (PI) Data Rept for Revised Reactor Oversight Process Pilot Program.Rept Constitutes Second Monthly PI Data Submittal from Pilot Plant Licensees,Which Includes Data Through May 1999 ML20207G4241999-06-0202 June 1999 Notification of 990630 Meeting with Util in Fort Calhoun, Nebraska to Discuss Miscellaneous Management Topics & Plant Status ML20207D3251999-05-28028 May 1999 Notification of 990617 Meeting with Util in Blair,Nebraska to Inform Public of NRC Plans for Implementing Risk Informed Baseline Insp Pilot Program at Fort Calhoun Station ML20210F7021999-04-30030 April 1999 Requests Waiver of Fees for Thirteen Dockets That Compromise Plant Population for NRR Pilot Regulatory Oversight Program. Purposes of Pilot Program Described in Commission Papers SECY-99-007 & SECY-99-007A ML20205N1741999-04-12012 April 1999 Notification of Revised Licensee Meeting with Util on 990419 to Discuss Results of PPR Completed 990211.New Location of Meeting Will Be in Visiting Inspector room,2nd Floor at Fort Calhoun Station,Admin Bldg,Fort Calhoun,Ne ML20204J0221999-03-19019 March 1999 Notification of 990419 Meeting with Omaha Public Power District to Discuss Results of Plant Performance Review Completed on 990211 ML20207L7181999-03-0202 March 1999 Notification of 990318 Meeting with OPPD in Rockville, Maryland to Discuss OPPD NPSH Calculation Used to Support Fort Calhoun Station USAR Change to Take Credit for Containment Overpressure or Sump Subcooling ML20198M3071998-12-31031 December 1998 Notification of 990114 Meeting with Util in Rockville,Md to Discuss Fort Calhoun Station Radiological Consequences Improvement Program Issues & Implementation ML20196D3341998-11-24024 November 1998 Notification of 981204 Meeting with Util in Rockville,Md to Discuss Fort Calhoun Station Radiological Consequences Improvement Program Issues & Implementation ML20195B4071998-11-0404 November 1998 Notification of 981130 Licensee Meeting with Util in Arlington,Tx to Discuss Recent License Exam Results ML20154L3781998-10-15015 October 1998 Notification of 981020 Meeting W/Util to Discuss Regional Administrator OPPD Common Cause Analysis ML20154C2211998-10-0101 October 1998 Notification of Licensee Meeting with Util on 981015 in Arlington,Tx to Discuss Maint & Engineering Issues Related to turbine-driven & diesel-driven Auxiliary Feedwater Pumps Overspeed Events ML20153D7441998-09-21021 September 1998 Notification of 981006 Meeting with Util in Fort Calhoun,Ne to Discuss Common Cause Analysis ML20236X5111998-08-0606 August 1998 Notification of 980819 Meeting W/Omaha Public Power District in Rockville,Md to Discuss Fort Calhoun Station Refueling Outage Accomplishments,Challenges & Emerging Issues ML20236M9621998-07-0808 July 1998 Notification of 980723 Meeting W/Util in Arlington,Tx to Discuss Licensee Performance ML16342E1431998-06-22022 June 1998 Notification of 980722-24 Meeting W/Utils in Arlington,Texas to Conduct Examination Writing Workshop ML20249C6141998-06-22022 June 1998 Revised Notification of Licensee Meeting W/Util on 980710 to Discuss Switchyard Mods at Fort Calhoun Station ML20248L2961998-06-0505 June 1998 Notification of Significant Licensee Meeting W/Util on 980710 to Discuss Switchyard Mods at Fort Calhoun Station ML20247M1631998-05-14014 May 1998 Refers to GL 92-01,Rev 1,Supplement 1, Rv Structural Integrity, Issued in May 1995.RAI Re Plant 971013 Submittal of Revised Rv Weld Chemistry Valves Encl.Response Requested within 90 Days of Receipt of Ltr ML20217K3251998-04-28028 April 1998 Notification of 980505 Meeting W/Nebraska Public Power District in Arlington,Tx to Discuss Current Operations Dept Issues ML20203F7461998-02-23023 February 1998 Notification of 980309 Meeting W/Util in Arlington,Tx to Discuss Switchyard Mods at FCS ML20198E2091997-12-30030 December 1997 Requests Attached 4 Pages Be Placed in Docket File & Pdr. Suppl to 961120 Application to Amend Fort Calhoun License & Tss.Document Faxed Concurrence of License Commitment Re Relocation of Certain TS Requirements ML20199H2531997-11-24024 November 1997 Forwards Signed Original of Order Prohibiting Involvement in NRC-licensed Activities (Effective Immediately) Fs Bandy,For Transmittal to Ofc of Fr for Publication.W/O Encl ML20198Q2461997-10-31031 October 1997 Notification of 971113 Meeting W/Util in Rockville,Md to Discuss Issues Related to FCS Fire Protection Improvements, USAR Verification & OPPD Proposal for Submitting Substantial TS Changes in Lieu of Coverting to Std TS ML20217B4311997-09-22022 September 1997 Notification of 971007 Predecisional Enforcement Conference W/Util in Arlington,Tx to Discuss Disabling of Containment Spray Sys ML20210N8801997-08-21021 August 1997 Notification of Licensee Meeting W/Util on 970924 in Blair, Ne to Discuss Systematic Assessment of Licensee Performance. Meeting Open to Attendance by Members of General Public ML20217M0521997-08-14014 August 1997 Informs That Operator Licensing Exams Administered on 970414-0506 at Fort Calhoun,Unit 1.Listed Info for Processing Through Nudocs & Distribution to NRC Staff Including NRC PDR Also Encl ML20210J0951997-08-0505 August 1997 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam at Facility on 971008.Requests That Listing of Names of Candidates for Exam Be Submitted to Listed Individuals by 970908 ML20141G9081997-07-0707 July 1997 Notification of 970721 Predecisional Enforcement Conference in Arlington,Texas to Discuss Apparent Violation of 10CFR50.65 Related to 970421 Steamline Rupture Event ML16342D6551997-05-16016 May 1997 Notification of Licensee Meeting W/Util on 970529-30 to Conduct Workshop on Test Item & Exam Development to Meet Agency Expectations of Facility licensee-developed Initial Licensing Exam.Proposed Agenda Encl ML20138E3261997-04-29029 April 1997 Notification of Significant Licensee Meeting W/Util on 970505 to Discuss Steam Line Break,Root Cause Analysis & Corrective Actions ML20134P2231997-02-20020 February 1997 Discusses Ti 2515/122 Evaluation or Rosemount Pressure Transmitter Performance & Licensee Enhanced Surveillance Programs multi-plant Action B-122 ML16343A6961997-02-18018 February 1997 Notification of Licensee Meeting W/Util on 970225 in Arlington,Tx to Discuss Results of Region IV Util Group Review of NRC Enforcement Policy & Nonescalated Enforcement Process ML20133H7781997-01-14014 January 1997 Notification of Significant Licensee Meeting W/Util on 970129 in Arlington,Tx to Discuss Issues Re Post-Accident Sample Sys ML20129E7041995-12-29029 December 1995 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal) for Tests Administered on 951204-08 ML20136A7871995-12-19019 December 1995 Partially Withheld Memo Discussing Petition Filed by Jf Doherty Requesting Six Plant Reactors Be Immediately Shutdown & Directors Decision 95-22 Which Denies Request ML16342D0891995-10-10010 October 1995 Notification of Significant Licensee Meeting W/Listed Utils on 951109 to Discuss Pressure Locking & Thermal Binding of power-operated Gate Valves (GL 95-07).Meeting Agenda Encl ML16342D0301995-08-23023 August 1995 Notification of Significant Licensee Meeting W/Util on 950907 to Discuss Pilot Exam Development Program ML20059H8831994-01-24024 January 1994 Submits Daily Highlight Re 940127 Meeting W/Util in Rockville,Md to Discuss Plant Plans for Future Amends & Current Licensing Status ML20058K1231993-12-0202 December 1993 Forwards CS Wingo of FEMA Transmitting Final Exercise Rept for 930629 Exercise of Offsite Radiological Emergency Response Plans for Plant.Eight Deficiencies Noted During Exercise ML20057B3401993-09-13013 September 1993 Requests That NRR Provide Review of Concern Re Licensee TS Action Statement for Inoperable Channel for SIRWT Level to Determine If It Is Appropriate to Request Change Be Initiated to Plant TS 1999-08-31
[Table view] |
Text
July 1,1999 MEMORANDUM TO: Stephen Dembek, Chief, Section 2
(
i Project Directorate IV & Decommissioning l
Division of Licensing Project Management L. Raynard Wharton, Project Manager FROM:
Project Directorate IV & Decommissioning /s/
Division of Licensing Project Management
SUBJECT:
FORTHCOMING MEETING WITH OMAHA PUBLIC POWER DISTRICT AND COMBUSTION ENGINEERING REGARDING STAFF CONCERNS WITH PRESSURE TEMPERATURE LIMITS REPORT (PTLR) AND ASSOCIATED TOPICAL REPORT CE NPSD - 683 DATE & TIME:
July 14,1999 1:00 p.m - 4:00 p.m.
LOCATION:
One White Flint North 11555 Rockville Pike l
Room O 12-8-4 Rockville, Maryland 20852 PURPOSE:
To discuss staff concerns with OPPD's PTLR submittal and Combustion Engineering Owners Group (CEOG) Topical Report CE NPSD-683.
PARTICIPANTS *:
NRC OMAHA PUBLIC POWER DISTRICT S Richards R. Phelps S. Dembek T.Heng R. Wharton T. Matthews E. Weiss L. Lois ABB-CE J. Medoff A. Sowers M. Weston A. Ulses Westinohouse S. Anderson Docket No. 50-285
\\
cc: See next page t
CONTACT: L. Raynard Wharton j
301-415-1396
/ O\\
- Meetings between NRC technical staff and applicants or licensees are open for interested y
members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to " Commission Policy Statement on Staff Meetings Open to the Public" 59 Federal Reoister 48340,9/20/94.
To receive a copy of tnis document, indicate "c" in the box OFFICE PDIV-2/PM C PDIV-2/LA C PDIV-2/SC NAME RWharton EP @
h bekk b DATE 6 /3 0 /99 6 hsR /99 6 / 3D/99 DOCUMENT NAME: G:\\PDIV-2\\FortCalhoun\\71499MTG.WPD OFFICIAL RECORD COPY C "I A O f' O.
i 9907070351 990701 PDR ADOCK 05000295 l
P pm E
r M E:o g
i UNITED STATES
,j j
NUCLEAR REGULATORY COMMISSION
't WASHINGTON, D.C. 20066 0001 O
July 1,1999 MEMORANDUM TO: Stephen Dembek, Chief, Section 2 Project Directorate IV & Decommissioning D'visio of Lice sing roj Management FROM:
ard ha on, Project Manager Project Directorate IV & Decommissioning Division of Licensing Project Management
SUBJECT:
FORTHCOMING MEETING WITH OMAHA PUBLIC POWER DISTRICT AND COMBUSTION ENGINEERING REGARDING STAFF CONCERNS WITH PRESSURE TEMPERATURE LIMITS REPORT (PTLR) AND ASSOCIATED TOPICAL REPORT CE NPSD - 683 DATE & TIME:
July 14,1999 1:00 p.m - 4:00 p.m.
LOCATION:
One White Flint North 11555 Rockville Pike Room O 12-B-4 Rockville, Maryland 20852 PURPOSE:
To discuss staff concerns with OPPD's PTLR submittal and Combustion Engineering Owners Group (CEOG) Topical Report CE NPSD-683.
PARTICIPANTS *:
NBQ OMAHA PUBLIC POWER DISTRICT S Richards R. Phelps S. Dembek T.Heng R. Wharton T. Matthews E. Weiss L. Lois ABB-CE J. Medoff A. Sowers M. Weston A. Ulses Westinahouse S. Anderson Docket No. 50-285 cc: See next page CONTACT: L. Raynard Wharton 301-415-1396
- Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to " Commission Policy Statement on Staff Meetings Open to the Public" 59 Federal Reaister 48340,9/20/94.
(
Ft' Caihdn 3tation, Unit 1 cc:
Winston & Strawn Mr. S. K. Gambhir ATTN: Perry D. Robinson, Esq.
Division Manager - Nuclear Operations 1400 L Street, N.W.
Omaha Public Power District Washington, DC 20005-3502 Fort Calhoun Station FC-2-4 Adm.
Post Office Box 399 Mr. Jack Jensen, Chairman Hwy. 75 - North of Fort Calhoun Washington County Board Fort Calhoun, Nebraska 68023-0399 of Supervisors Blair, Nebraska 68008 Mr. Wayne Walker, Resident Inspector U.S. Nuclear Regulatory Commission Post Office Box 309 Fort Calhoun, Nebraska 68023 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Ms. Cheryl Rodgers, LLRW Program Manager Environmental Protection Section Nebraska Department of Health 301 Centennial Mall, South P.O. Box 95007 Lincoln, Nebraska 68509-5007 Mr. J. M. Solymossy Manager-Fort Calhoun Station Omaha Public Power District Fort Calhoun Station FC-1-1 Plant Post Office Box 399 Hwy. 75 - North of Fort Calhoun Fort Calhoun, Nebraska 68023 Mr. Mark T. Frans Manager-Nuclear Licensing Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.
Post Office Box 399 Hwy. 75 - North of Fort Calhoun Fort Calhoun, Nebraska 68023-0399 u