MONTHYEARML20116A0341996-07-17017 July 1996 Rev 0 to Temp Vs Distance Profile for 10 RHR Line Containing Stagnant Water ML20058Q4061993-08-30030 August 1993 Package Consisting of Employee Concerns Programs ML20128G9491993-01-22022 January 1993 Calculation of Weights Due to Fire Protection Matl ML20128G9551992-12-29029 December 1992 Design Validation of Conduits W/Thermolag ML20128G9861992-10-0202 October 1992 Ampacity of Power Cable Wrapped W/330-660 Installed as Free Air Drop ML20105A7981992-08-14014 August 1992 Rev 0 to Calculation of Thermal Response for Sprinkler & Raceway Supports ML20101G0471992-06-17017 June 1992 Rev 3 to Calculation 2-FP-0085 Raceway & Firezone R Cable Supports Analysis ML20115B6851992-03-0202 March 1992 Rev 0 to 2-NP-GENX-544, Reconciliation of Local Stress Evaluation Using ME215 Analysis ML20104B4001992-02-13013 February 1992 Rev 1 to Calculation RXE-TA-CP1/0-027, Undervoltage/ Underfrequency Reactor Trip Setpoints ML20127H2091991-11-12012 November 1991 Calculation 2-NP-GENX-551, Evaluation of NUREG-0797 Suppl 1A (Sser 14) App a Sections 12.1 & 12.2 ML20082U5851991-05-0808 May 1991 Liner Attachment Welds Serviceability ML20055E2881990-03-12012 March 1990 Package Consisting of Event Notification Worksheet Re 900312 Inadvertent Safety Injection from Single Train.No Equipment Malfunction/Failure Noted ML20072A8471990-01-23023 January 1990 Rev 2 to Calculation 071, Review Statement for Safety Related Calculations ML20042D3711989-09-28028 September 1989 Audit Rept ATP-89-146S, Scaling Calculations, on 890821-0928 ML20247G4111989-03-31031 March 1989 Transit Time Flow Meter Calculations ML20151T3841988-08-0101 August 1988 Protocol Between OSP & NRR for Technical Review of Comanche Peak Fsar ML20151K5841988-04-18018 April 1988 Page from Draft Rept on Plant Safeteam Activity & Ofc of Investigations Review IR 05000445/19820141988-03-11011 March 1988 Draft of Insp Rept 50-445/82-14 Originally Withheld from FOIA-84-210 Response & Typing Cover Sheets or Transmittal Pages of Documents Withheld from FOIA-86-181 Response ML20148F8201988-01-21021 January 1988 Rev 0 to Investigation of SIF for Weld Shrinkage ML20148F8631988-01-21021 January 1988 Rev 1 to Parallel Snubbers ML20148F2151987-11-19019 November 1987 Rev 0 to Potential Binding of Lugs in Axial Supports ML20237K9771987-08-19019 August 1987 Press Release 87-115 Informing of NRC Release of Documents Re Investigation of NRC Actions Involving Plant Under Const. Portions of Documents Deleted for Personal Privacy Reasons or Prospective Personnel Matters ML20151M9601987-07-20020 July 1987 Package of NRC Administered Requalification Exam Results Summary ML20148F2521987-05-22022 May 1987 Rev 0 to Evaluation of Fluid Transient Cutoff Forces & Development of Screening Criteria for Piping Sys ML20237K0381987-05-14014 May 1987 Record of 870514 Telcon W/S&W & Util Re Insp Requirements for Pipe Supports (Ref Item 4,SWEC NA-1140 Rept) ML20237K0201987-05-13013 May 1987 Record of 870513 Telcon W/S&W & Util Re Insp Requirements for Pipe Supports for Plant.S&W Does Not Consider Insp of Designs to Be Warranted ML20236M4011987-04-17017 April 1987 Package Consisting of 870417 Request for Premium Cost Mail Svc & Unsigned & Undated Ltr to Util Forwarding Draft Insp Repts 50-445/87-02 & 50-446/87-02 & Notice of Deviation ML20128G9681987-02-24024 February 1987 Cable Ampacity Derating Factors for Conduits Boxed in W/ Thermolag (TSI Product) ML20236L9091987-02-19019 February 1987 Rev 1 to CT-1-137-701-S25R, Pipe Support Calculation ML20236N4981987-02-0202 February 1987 Package Consisting of Comanche Peak Steam Electric Station Design Change Authorizations & Evaluation Summaries ML20207D7231986-12-23023 December 1986 Pipe Support Calculation:General Calculation for Richmond Insert/Tube Steel Connections Design Mods ML20207D7481986-12-23023 December 1986 Generic Calculation:Evaluation of Npsi Rear Brackets, Dimension for Design Calculation IA-86-386, Package Consisting of Potential Violations Not Included in Proposed Enforcement Package & Violations of Little Safety Significance Not Included in Proposed Enforcement Package1986-12-16016 December 1986 Package Consisting of Potential Violations Not Included in Proposed Enforcement Package & Violations of Little Safety Significance Not Included in Proposed Enforcement Package ML20211P4701986-12-16016 December 1986 Package Consisting of Potential Violations Not Included in Proposed Enforcement Package & Violations of Little Safety Significance Not Included in Proposed Enforcement Package IA-85-799, Partially Withheld Package of Info Re Plant Investigation, Including Draft NRC Ltr to Aslb,Partial Transcript & Handwritten Notes1986-12-0101 December 1986 Partially Withheld Package of Info Re Plant Investigation, Including Draft NRC Ltr to Aslb,Partial Transcript & Handwritten Notes ML20214R3351986-12-0101 December 1986 Partially Withheld Package of Info Re Plant Investigation, Including Draft NRC Ltr to Aslb,Partial Transcript & Handwritten Notes ML20235S1101986-11-15015 November 1986 Package of Documents Re Nomination & Authorization for Cash Awards to NRC Personnel Involved W/Insp Efforts Re Implementation of Util Comanche Peak Response Team Program IA-87-528, Package of Documents Re Nomination & Authorization for Cash Awards to NRC Personnel Involved W/Insp Efforts Re Implementation of Util Comanche Peak Response Team Program1986-11-15015 November 1986 Package of Documents Re Nomination & Authorization for Cash Awards to NRC Personnel Involved W/Insp Efforts Re Implementation of Util Comanche Peak Response Team Program ML20210E5991986-11-0707 November 1986 Rev 2 to Calculation 020-040-M19, Clip Stiffness Production Value ML20210E6811986-10-31031 October 1986 Rev 4 to Calculation M-03, Cable Tray Properties ML20236L8891986-10-31031 October 1986 Rev 1 to CT-1-137-702-S25R, Pipe Support Calculation. Supporting Documentation Encl ML20210E5221986-10-15015 October 1986 Rev 2 to Calculation M-10, Cable Tray - Clip Angle Stiffness ML20210E5751986-10-10010 October 1986 Rev 2 to Calculation M-12, Qualification Procedures for Cable Tray Support Evaluation ML20148F4591986-09-16016 September 1986 Rev 0 to Fatigue Cycle Determination for Pipe Supports ML20148F4921986-09-10010 September 1986 Rev 2 to Documentation of Use of Low Strength A563 Grade a Double Nuts on High Strength SA 193 Grade B-7th D Rod for Richmond Insert Bolt Connection ML20210E6261986-08-31031 August 1986 Rev 0 to Calculation M-28, Justification of Clip Modeling Procedure ML20148F3351986-08-28028 August 1986 Rev 2 to Development of Method for Evaluating Local Stress in Pipe Support Members ML20210E4611986-08-25025 August 1986 Rev 3 to Calculation M-25, Base Plate Prying Action Factors ML20236L9371986-07-31031 July 1986 Rev 1 to Calculation CT-1-032, Texas Util Generating Co Comanche Peak Steam Electric Station Containment Spray Sys 15454-NP(H) ML20211K2971986-06-11011 June 1986 Partially Withheld Package of 850711 & 860611 Lists of Allegations on Comanche Peak 1996-07-17
[Table view] Category:TELEPHONE OR VERBAL CONVERSATION RECORD
MONTHYEARML20237K0381987-05-14014 May 1987 Record of 870514 Telcon W/S&W & Util Re Insp Requirements for Pipe Supports (Ref Item 4,SWEC NA-1140 Rept) ML20237K0201987-05-13013 May 1987 Record of 870513 Telcon W/S&W & Util Re Insp Requirements for Pipe Supports for Plant.S&W Does Not Consider Insp of Designs to Be Warranted ML20134J9451985-06-17017 June 1985 Telcon W/Rm Grant on 850617 Re Reinsp of Structural Welds in Power Block ML20206U6031985-01-27027 January 1985 Record of 850127 Telcon W/Alleger A-31 to Discuss Concern Re Const of Facility ML20134G0411984-12-28028 December 1984 Telcon W/Members of Comanche Peak Project Technical Review Team & Util on 841228 Re Util Action Items.Nrc Briefed Re Util Approach to as-built Concrete Schmidt Hammer Test Work IA-86-217, Partially Withheld Record of 840614 Telcon Between D Andrews & B Hayes Re Drug Investigation at Plant1984-06-15015 June 1984 Partially Withheld Record of 840614 Telcon Between D Andrews & B Hayes Re Drug Investigation at Plant ML20215E3631984-06-15015 June 1984 Partially Withheld Record of 840614 Telcon Between D Andrews & B Hayes Re Drug Investigation at Plant 1987-05-14
[Table view] |
Text
' u5 _ ~..~ ~' m STONE G WE8 STER ~ ENGINEERING ~COWP6iiATION QUA LITY ASSURANCE DEPARTMENT NOTES OF TELEPHONE CONVERSATION ;
1 T-1928 CALL DATE 6/17/85 TIME 2:15 P.M.
~
PROJECT Comanche Peak a , o, 15297.00 -
FROM: TO:
H.F. Faery NAME .R.M. Grant l Asst. Chief Engineer, NDT Division TI M Director, QA, Kansas Gas & Electric SWEC Boston i ADDRESS Wolf Creek Generating Station (617) 589-5185 TELEPHONE (316) 364-8831 X2230 SUBJECT Re-inspection of Structural Welds in Power Block - Reference CAR 19 j l
SUMMARY
Inspection of welds was carried out through the coating. Welds had previously been inspected and accepted, but some records were misplaced, thus requiring a reinspection. NRC did sample inspections to check our results, even I
used MT on 59 joints through the paint, then had the paint removed for verification.
No defects were found.
l 1
l l ACTION REQUIRED l
i l
COPY TO:
v Q'N g(f"
/
SIG N ATURE '
/< im '
B508290528 850617 5 '4 ,/
ADOCK 0500 ,p,_w 3,t _f u _,
{DR , _