Westinghouse Proprietarf Class 3 Preliminary Draft l

l l

. Method for Calculating the PCS Film Coverage Input for the AP600 Containment DBA Evaluation Model I

May 15,1996 R. P. Ofstun D. R. Spencer J. Woodcock S. K. Slabaugh M. Sredzienski b

i I

1 9605290199 960521 PDR ADOCK 05200003 A

PDR

Westinghouse Proprietary Class 3 Preliminary Draft l

Execudve Summary l

The purpose of this chapter of the Applications Report is to describe the method useN le 9

3

=

3

+

s T

wi D

l

$a M

f*

4 9

9

+

4 i

L i

a 1

m>

l t

19 f

Westinghouse Proprietary Class 3 Preliminary Draft 8.2.6 Estimated AP600 Range of Film Coverage Parameters The estimates for the maximum and minimum values for the range of AP600 film coverage parameters during a DBA are calculated using the simple approach described below. The AP600 range of film coverage parameters is compared with the range of the PCS tests.

A conservative estimate for the gravity driven PCS water flow rate is calculated assuming a single failure of I of 2 valves (located in parallel) to open. This Gow rate is shown in Figure i

8-3. A combination of 3 standpipes is used along with orifices to adjust the delivered now rate j

with time. The flow rate is adjusted based on decay heat removal requirements. Note, the largest flow resistance is in the orifices, so the single failure assumption reduces the gravity driven flow rate by less than 2 percent. The flow rate decreases with time as the water level in the PCS. storage tank decreases. The 2 large decreases in flow rate (at about 5 and 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />) occur when the water level falls below the first and second standpipes. The minimum PCS flow rate occurs after about 3 days. Values of 220 gpm and 55 gpm are used for the maximum and minimum PCS flow rates in the calculations below.

The minimum sidewall film Dow rate, F, would ~be 0 lbm/hr-ft. To determine a maximum sidewall F, only 25% of the film is assumed to evaporate on the dome. It is likely that there would be more evaporation from the dome, which would reduce the film flow rate to the sidewall. Wi'th a 25% reduction in the PCS flow to the sidewall, measurements from the unheated, phase 3 Water Distribution Tests indicate that approximately 75% of the perimeter at the top of the sidewall will be wetted, resulting in an estimated maximum sidewall film flow rate of 256 lbm/hr-ft. At the estimated maximum 200*F film temperature, the sidewall Re, would n

be 1400. The Re and F values on the dome will be higher than the sidewall values since F no decreases as the diameter increases. A more detailed comparison of the expected AP600 Re e n

value with test data is given in Ref. 8.8.

The internal shell heat flux provides the boundary conditions for the evaporating film.

Condensation is the primary source of energy transfer to the internal surface of the shell. The condensation rate is dependent on the internal gas velocity along the shell, the internal steam distribution and the internal shell temperature. Large-scale test data indicate that the volume above the operating deck will be well mixed by the high velocity break jet during a MSLB event and the early blowdown phase of a LOCA event, but will be stably stratified (i.e. a vertical, density gradient will form) during the post-blowdown portion of a LOCA event. The shell temperature is highest in locations where the exterior surface is dry.

13

r 1

l Westinghouse Proprietary Class 3 Preliminary Draft 1

1 8

R

-8

?

n o*L 2

i O

Ev O

o._

m s g

- o e

O i

R 8

8.-

8.-

o,r a

~

Cwco) asse moig e

Figure 8 Conservative Estimate of the Gravity Driven PCS Flow Rate 14

Westinghouse Proprietary Class 3 Preliminary Draft The steady state shell average heat flux and film temperature were calculated for the subcooled, evaporating and dry portions of the shell assuming an initial ambient air and film temperature of 120*F. These calculations were performed at the containment design pressure,45 psig, to bound conditions at the expected DBA peak pressure and at 22.5 psig, for conditions representative of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after blowdown. The results are tabulated below.

Containment Avg. Subcooled Avg. Evaporating Avg. Dry Pressure Heat Flux Temp. Heat Flux Temp. Heat Flux Temp.

2 2

(psig)

(BTU /hr-ft ) (*F)

(BTU /hr-ft ) (.F)

(BTU /hr-ft ) (*F)

,_=

45' 7740 155 5500 190 455 260 22.5 3700 147 2500 175 300 220 The maximum wet shell heat flux is estimated to be 50% higher than the average subcooled 2

value (at 45 psig); this would be about 11500 BTU /hr-ft. The minimum wet shell heat flux is estimated to be at least 50% lower than the average evaporating value (at 22.5 psig); this would 2

be about 1300 BTU /hr-ft,

Per the Technical Specifications, the initial PCS film temperature will be between 50 and 120*F.

The 120*F value is used in the DBA evaluation model to minimize the benefit of sensible heat removal by the subcooled film. The film temperature will increase as the film flows down the dome and onto the sidewall. The maximum evaporating film temperature was estimated to be less than 200*F. Since the resistance to heat transfer through the thin film is very small (compared with the mass transfer and internal resistance, as shown in Ref. 8.9) and the heat flux is relatively low, the maximum wet shell surface temperature is estimated to be less than 20*F higher than the maximum film temperature.

The estimated range of the AP600 film parameters during a DBA is summarized in Table 8 6.

A comparison with the PCS test data range shows that, with the exception of the maximum evaporating film temperature and maximum sidewall Re number, the test data bounds the r

estimated range of the AP600 film parameters.

Table 8 Comparison of the Range of Film Coverage Parameters 40 9

/

l l

i

~

l

~

15

1 l

Westinghouse Proprietary Class 3 Preliminary Draft The test data parameter ranges are sufficient for evaluating the film stability model even though the estimated maximum film temperature and maximum Re are not covered. it is more n

important to cover the lower expected film temperature with the test data, than the higher expected film temperature since the film is less stable at lower film temperatures. Also, it is more important for the tests to cover the minimum sidewall Re for evaluating the film stability n

model. Also note, the test data for the maximum sidewall Re number is within the wavy n

laminar flow regime, while the maximum AP600 sidewall value is in the transition to turbulent flow regime. The resistance to heat transfer through the film is lower in the turbulent flow regime than in the laminar flow regime, so even though the tests did not cover the transition regime, the test results are conservative with respect to evaluating the resistance to heat transfer.

s 4

9 4

6 1

f 16

Westinghouse Proprietary Class 3 Preliminary Draft i

i l

8.3 AP600 Transient Wetting Behavior Water begins to flow onto the top of the AP600 containment vessel shortly after the PCS actuation signal occurs. The time sequence of events to establish steady state water coverage of the AP600 followmg actuation of the PCS is shown in Table 8-7 below.

I Table 8-7 PCS Time Sequence of Events l

Event Time (sec)

Signal Actuation 0

l Valve Strokes Open 20 Piping Fills 50 Bucket Fills & Spills 53-First Weir Fills & Spills 203 Second Weir Fills & Spills 353 Steady State Established 653 The maximum time for water to begin flowing onto the shell surface, following a postulated event that actuates the PCS, is 53 seconds and is based on a maximum 20 second valve stroke time plus 30 seconds to fill the pipes and 3 aconds to fill the bucket.

The Water Distribution Tests (described earlier) were used to test the ability of various weir designs to cover a large fraction of the containment shell with water and to determine the time to establish steady state film coverage on the AP600. Based on a review of the video tapes of the phase 3 (improved weir design) Water Distribution Tests, the time to fill and begin to spill over the first weir with a flow rate of 27.5 gpm (equivalent to the single valve failure flow rate of 220 gpm on AP600) was conservatively estimated to be about 2 5 irjnutes; the time to fill and begin to spill over the second weir was conservatively estimated to be about 5 minutes: and the total ~ time to establish steady state coverage of the dome and sidewall was estimated to be about 10 minutes.

The shell surface temperature continues to increase during the pered to establish steady state coverage. The time for the dry outer shell to reach a given temperature is a function of the internal containment air temperature, the internal energy transfer coefficient and the shell thickness. It can be calculated using the properties of the [

]" steel shell and Figure 4-8 from Kreith (Ref.'8.10).

The initial shell temperature is assumed to be 120*F. The time for the dry external shell surface temperature to reach the boiling point (212*F) can be calculated with the following input:

l T

= 212*F (external shell surface temperature) l T,

= 120*F (initial shell temperature)

T.,

= 250*F (internal containment air temperature)

= (T - T.J/(T, - T ) = 0.292 17

Westinghouse Propiietary Class 3 Preliminary Draft The propenies of the steel shell are given below:

k,

= 25 BTU /hr ft-F (thermal conductivity)

L

=[

]" ft (thickness) 2 a

= 0.49 ft /hr (thermal diffusivity)

If the internal energy transfer coefficient (primarily condensation in air) is assumed to be much larger than the external energy transfer coefficient (primarily forced convection) such that the dry outer shell surface can be considered adiabatic (insulated) over the time period of interest. then the time to reach 212*F will be minimized. The results of the calculation are tabulated as a function of the internal energy transfer coefficient below:

j 2

2 U (BTU /hr-ft -F) 1/Bi at/L t (seconds) 5 34.3 43 5792 10 17.1 22 2963 50 3.43 5

673 100 1.71 2.6 350 The average, internal energy transfer coefficient for AP600 following a DB A LOCA is estimated 2

to be about 75 BTU /hr-ft F, therefore, the time for the dry outer containment shell temperature to reach the boiling poin' is estimated to be between 400 and 600 seconds.'

t A WGOTHIC AP600 model was run for comparison with the hand calculations. The calculated temperatures at the top of the dome, before application of the PCS film, are shown in Figure 8-4.

Figure 8-5 shows that condensation provides the bulk of the internal energy transfer to the shell.

During the 10 minute transient time after the initial blowdown, the containment temperature (and,

therefore the maximum possible internal shell temierature) is maintained at about 260*F by j

i condensation on the heat sinks inside containment. The WGOTHIC calculation of the time for i

the shell surface temperature on ' top of the dome to reach 212*F (about 450 seconds) agrees reasonably well with the estimate above. The heatup rate is about 0.2'F/sec and falls between the 50 and 100 BTU /hr-ft -F internal energy transfer coefficient values assumed in the hand 2

calculation.

The calculated temperature increase in the dry external shell surface is shown as a function of time in Table 8-8 below.

Table 8-8 increase in Dry, External Event Time (sec)

Shell Temp. (F)

Signal Actuation 0

0 Valve Strokes Open 20 Piping Fills 50 Bucket Fills & Spills 53 10 First Weir Fills & Spills 203 50 Second Weir Fills & Spills 353 70 Steady State Established 653 120 18

Westinghouse Proprietary Class 3 Preliminary Draft l

l l

At the maximum time delay for water application to the shell (53 seconds, from Table 8-7), the j

outer shell temperature will have increased by less than l0*F. The temperature of the dry ponion l

of the outer shell will have increased by less than 50*F at the time the first weir begins to spill '

(about 203 seconds) and less than 70*F at the time the second weir begins to spill (about 353 seconds). Therefore, the sidewall temperature will be less than 200*F at the time the stripes of water film begin to advance down the vertical surface. The outer shell surface temperature for the dry regions of the dome and sidewall will not exceed 240*F befc e steady state water coverage is established.

Water coverage is not adversely affected by application of the film to a hot, dry shell surface.

l Tests run during the PCS testing program verified the ability of the water film to wet and rewet l

a hot, dry. surface (temperature exceeding 240*F) coated with the inorganic zine compound.

i Video tapes of the STC ' wet flat plate show the initial wetting, dryout and re wetting of a hot.

l dry plate in both a venical and inclined position. The dry plate temperature was estimated to be about 240*F (based on the maximum heating fluid temperature). An applied wavy laminar film l

quickly covered the hot, dry plate. As the flow rate was reduced, the waves in the film became smaller and eventually disappeared. The plate remained visibly wet until after the film flow was turned off, then dry patches appeared and grew in circumference as the plate dried out. Video tapes also show the initial wetting of the large-scale test vessel. The measured shell surface temperature was about 260*F at the time the water was applied. The film front was observed to

" sizzle" as it quickly advanced downward and covered the surface of the elliptical dome.

I I

)

i

)

l 19

Westinghouse Proprietary Class 3 Preliminary Draft 8

m 11 11 g

~

O e

U C

II w

m 11

~

8

?

W ll e

V m

W u)

C 1

1 U

g

.- o C m O o

U Q

U1 11 V

I h

0 8

L G

~

G V

E C

O.

w U)

L i

Il g

3 E W w

0 11 a

It

- o C f W

j ll C

e 16

- u i

0 11 I

m L

li o

S 8

8 8

8 8

m n

~

~

Cd) aanteaadwal Figure 8 Shell Temperatures at the Top of the Dome (without PCS Film Flow) 20

\\

Westinghouse Proprietary Class 3 Preliminary Draft j

o 8

i i

c 11 o

g aem 11 C

0u n

C tn O

1 11 V U oo C m o o

V

)

e ll u

I i

11-og a

V O

4 Il C

O U

!! 8 n

11 ll ll 11 I

3O o

8 8

8 8,

8 8

8, e

~

Cs/nia) eco;;ns i iaus episui o2 asse se1sua;1 x0;eug Figure 8 Comparison of Internal Condensation and Convective Energy Transfer at the Top of The Dome 21

Westinghouse Proprietary Class 3 Preliminary Draft 8.4 Analytical Model for Determining Film Stability The stability of liquid films has attracted the attention of many analysts and experimenters over the last 40 years and has been examined from two different points of view: looking at the minimum flow rate required to re-wet a stable dry patch, or looking at the thermocapillary breakdown of the thin film. Norman and McIntyre (Ref. 8.11) presented data that showed a large increase in the minimum film wetting rate was required as the temperature difference between the sudace and film was increased. Hallett (Ref. 8.12) also observed this phenomena and developed a film breakdown correlation that was related to the film surface tension difference, the wave number and the heat transfer coefficient. Fujita and Ueda (Ref. 8.13) measured the breakdown of both subcooled and saturated liquid films on heated, venical, polished, stainless steel tubes, A comparison of the results from their tests also showed that the highly subcooled films' beconie unstable at flow rates several times higher than saturated films. More recently, Bohn and Davis (Ref. 8.14) also measured the breakdown of subcooled water films on heated.

vertical, polished, stainless steel tubes and developed a film breakdown correlation that was dependent on thermocapillary effects.

Subcooled films, with temperatures much lower than the solid surface temperature, absorb heat j

causing the film temperature to increase. Evaporating nims, that are more nearly in thermal i

equilibrium with the solid surface, transfer mass and energy from the film sudace to the gas atmosphere. An apparent explanation for the reduced stability of subcooled films is the existenc,e j

of significantly higher temperature gradients that give rise to increased thermocapillary forces.

The list of papers considered for application to AP600 is extensive and will not be given here.

However, in a summary article (Ref. 8.15), Bankoff provided an extensive list of relevant papers, many of which have been considend for application to AP600. The current state of the art is focused on the " moving contact line", which was also considered for application to AP600, but is generally not very practical for engineering application. Overall, investigators have identified momentum, surface tension, thermocapillary, and vapor thrust as the dominant forces affecting o film stability. These forces are typically expressed as functions of flow rate, heat flux, fluid properties, and wetting angle. Vapor thmst can be neglected in AP600 because the heat flux is low, less than 10,000 BTU /hr-ft.

Consequently, for AP600, it is necessary to address 2

momentum, surface tension, and thermocapillary forces.

The model selected to perform AP600 film stability calculations was developed by Zuber and Staub (Ref. 8.16) to predict the conditions under which a stable dry patch will form. Since this model relies on local film and surface conditions, it is applicable to any size stmetum.

The Zuber-Staub model considers the stability of a dry patch located within a uniform, flowing i

l film, i.e. the inability of the liquid film to recover the dry patch. The Zuber-Staub model uses l

a venical force balance at the tip of a postulated dry patch to detennine the minimum uniform film thickness required to rewet the dry patch. This minimum film thickness is a function of the surface heat flux, the film properties (including the contact angle between the film and surface),

and the surface inclination angle.

l 22 I

Westinghouse Proprietary Class 3 Preliminary Draft l

According to the Zuber-Staub model, if the uniform film thickness 'were greater than the minimum stability value, any dry patch created in the film would be washed over and would readily disappear after formation due to the momentum of the flowing film. Conversely, if the film thickness were equal to or less than the minimum stability value, a dry patch, if formed.

would be predicted to be stable, i.e. the uniform film would not be able to recover the dry patch.

The Zuber-Staub model does not consider the effects of waves in recovering the dry patch.

1 A modified form of the Zuber-Staub model (shown below) was selected for AP600 because it includes each of the dominant terms: momentum, surface tension, and thermocapillary.

PUON0 + pgoosp.

= A-(1-cos0) + bIcos0 15p 2

6 dT k 2

where:

0 = the contact angle between the surface and film p = the surface angle of inclination relative to horizontal a = the liquid surface tension da/dT = the liquid surface tension temperature derivative q" = the surface heat flux k = the liquid thermal conductivity p = the li. quid density

. p = the lig'uid viscosity g = the gravitational constant i

S = the minimum stable film thickness A body force term was added to account for spreading on the inclined surface of the elliptical dome and the vapor thrust term was eliminated.

)

8.4.1 AP600 Film Stability Model Sensitivities The mass flow rate per unit perimeter, F, is more easily measured than the film thickness. The average film thickness in laminar film flow is related to F as follows:

31'p 3,

2

.gsinpp The sensitivity of the predicted F., value to the contact angle and film temperature is shown as a function of heat flux in Figures 8-6 and 8-7 (for film temperatures of 120 and 200*F respectively). F., decreases with increasing film temperature, consistent with test observations.

At very small contact angles, F., increases as the heat flux increases. At larger contact angles (0 > 10'). F., is not very sensitive to the estimated AP600 heat flux range during a DBA.

I 23

l q n E.53oc1 mgo:.22E4 "t M*

)

9 5

y%2B5eQ' UD2 o

0000 1

m

.e m

0 0

2 00 )

1 2 t

f r

++

h 3

/

U 1

T

=

B

(

c.

x u

l F

=,

t a

n 0 e

=

2

+

i 0

0 H 1

m

+

i

+

i F

2 0

_0 1

0 0

0 0

o 0

5 0

5 2

1 1

nawIh 'Ea v 3O a

ex a E&5aC Nc mgca IoQ3 3 ocN ? m. va 5' 3 cB g Eo ::.n 3 3ogWu8e~"faEnCr s

o r E o Iop g 5 Eo I y oo to" E ~ og 1 g aoByaeCN 3

.q--

mr=Og ="

o T

n wu

l t

,l Qnn.5 = roc $ yooE' aQ n5=

t.a c

m n,__ 5'5' A Q O,$

000

.ti 0

0 1

00 00 )

1 2 t

f r

+

h

/

U T

~

B

(

x u

l F

t a

0 e 0

^_

=+

7 0 H 1

, +

m i

i F

a

=

- 0 0

1 0

0 0

0 o

0 5

0 s,

2 1

=

nv+ILC'Ea U b

ce K CQa-rcR oem.

veo gcB esEa m=:.3 "Uog fR* yE_y= E 9'a EO~.daaNcpg>

r c

n P. a

=

~

e t:cg.=" N=5q 4 O aon~ 5 B" qn ll-* >boEN$oTm sB3a~CR nr c

U a

eu a

l l

Westinghouse Proprietary Class 3 Preliminary Draft 8.4.2 Contact Angle and Surface Wettability The contact angle between a water film and the surface is an important input to the AP600 film stability model. The contact angle is an indication of the surface wettability. Better wetting occurs on surfaces with small contact angles. Contact angles are measured for both advancing l

and receding films and usually the two values are quite different with the advancing contact angle being much larger than the receding contact angle.

l The AP600 containment shell surface will be coated with an inorganic zine compound for corrosion protection. The contact angle for a slowly advancing drop of water was measured as

, a function o'f temperature and age of the surface. These results are presented in Ref. 8-17 and

. show the advancing contact angle for this surface decreases with age and temperature, and is between [

]" for a new surface, and between [

]" after just 2 years of weathering. An advancing contact angle value of [

]" was chosen for the film stability calculations because it is the upper bound of the measured, steady state values for a heated, weathered surface.

A small drop of water spread around on the inorganic zinc coated surface does not contract, or snap back into a drop, demonstrating that the receding contact angle is nearly zero. Because the receding wetting angle is nearly zero, the film is expected to flow in constant width stripes down from the vessel springline (top of the vertical cylinder). This is consistent with observations qf the film behavior on the Large Scale Tests discussed earlier. From another point of view, these observations imply that the film breakdown to form a dry spot occurs at a lower film Reynolds number than the critical Reynolds number for rewetting. This is not surprising, since the contact angle formed in enlarging a small dry spot is smaller (~0 ) than in rewetting it.

A solid surface will be wet with liquid if the free surface energy of the solid is greater than the surface tension of the liquid. Surface tension, o, is defined as the work required to expand the surface of a liquid by a unit of area. It is a measure of the strength of the intermolecular forces in the fluid, similar to the latent h' at of vaporization.

e Hydrogen bonding is the strongest type of intermolecular force. Liquid water has relatively strong intermolecular forces due to the strong hydrogen bonds: 80% of the intermolecular attraction'in water is attributed to hydrogen bonding. In a water molecule, the electrons spend more time in the vicinity of the oxygen atom than the hydrogen atoms because oxygen is more electro-negative than hydrogen (3.5 vs. 2.1 for hydrogen on a scale of 4.0). This results in an electric dipole within the molecule. For this reason water is said to be a polar molecule.

As temperature increases, the mean spacing between molecules in a liquid increases causing the density to decrease and a reduction in the intermolecular forces. Therefore, both a and the latent heat of vaporization decrease with increasing temperature. For example, the surface tension of water is about 4.97E-03 lbf/ft and the latent heat of vaporization is about 1054 BTU /lbm at room temperature. These decrease to 4.0E-03 lbf/ft and 970 BTU /lbm respectively at 212*F.

I i

26

Westinghouse Proprietary Class 3 Preliminary Draft The wetting of a solid surface by water is improved by reducing the surface tension of the water (by use of a wetting agent, such as a detergent) or by making the surface more porous (to improve the spreading by capillary action). The porosity of the inorganic zine coating is believed to be the primary factor affecting wetting early in life. It was postulated that the buildup of polar molecules (e.g., oxides of Zn) on the surface improved the wetting with age. Tests on both new and weathered surface coating samples were performed using a scanning electron microscope with an energy dispersive X-ray spectrometer to identify the chemical species present on the surface. More oxides of zine were found on the weathered surface, supporting the hypothesis that the increase in wetting is due to the surface becoming more polar as it ages.

Buildup of some surface contaminants can result in a reduction in wettability. The worst surface contaminant is silicone because it has a very low surface energy and low polarity. Other surface contaminants, that could result in reduced wetting, include hydrocarbons; i.e. oils, members of the PTFE family (Teflon), polypropylene and polyethylene residues. The coatings vendor has a standard cleaning procedure and a specially developed detergent available that emulsifies these types of surface contaminants so they can be. washed away.

Although the number of potential contaminants that would adversely affect wetting is probably limited to a dozen or so, it would be very difficult to analytically predict the wetting degradation over time. We would have to estimate the degradation of surface wettablility as a function of

'the concentration of each, the deposition rate of each as a function of the local or worst case atmospheric condidons, assume the degradation is additive, etc. Therefore, periodic In-Service Inspections will' be performed to sample the surface for wettability. The frequency and procedures for testing and the minimum acceptance criteria prior to cleaning the surface are defined in the Reliability Assurance Program.

8.4.3 Comparison of the AP600 Film Stability Model with Test Data The PCS tests provided measurements of film flow rates on the prototypical AP600 surface.

' Stable, evaporating films were produced in the STC wet flat plate tests and the small-scale tests.

Subcooled film breakdown was observed to occur just below the J-tube location on the dome in some of the large-scale tests, as described in Section 8.2.5, but the evaporating film stripes that traveled down the vertical sidewall remained stable and maintained a relatively constant width.

A compilation of the film data from these 3 tests is provided in Tables 8-3,8-4 and 8-5.

The lowest measured film flow rates from the PCS tests are shown in Figures 8-6 and 8-7 for comparison with the modified Zuber-Staub film stability model calculations. Note, these data points represent stable, evaporating films on the vertical, prototypical surface. These measured film flow rates are significantly lower than the predicted stability limit calculated with the model (using a measured contact angle of [

1"). Therefore, the modified Zuber-Staub film stability model will over-predict the breakdown flow rate of evaporating films on the vertical sidewall of the AP600 containment.

27

__.______.__._____.______.,_-_____._._m._.

i Westinghouse Proprietary Class 3 Preliminary Draft The br:akdown of subcooled films was observed on the prototypical surface in some of the large-scale tests, but it was not accurately measured. The heat flux and film flow rate at the point of breakdown were estimated using the measured data on the top of the dome.

The estimated film Re number at breakdown is shown as a function of the maximum dome heat flux in Figure 8-8. For comparison, minimum stable film Re number curves are calculated using both the modified Zuber-Staub film stability model and the AP600 film stability model with a

[

]" advancing contact angle, an estimated surface inclination angle (at the breakdown location) of 20* and an estimated film temperature (at the breakdown location) of 80*F. Note, as described later in this section, the AP600 film stability model includes a multiplier for subcooled film breakdown that bounds all of the PCS test data. The estimated film Re number at breakdown is, in most cases, higher than the predicted stability limit calculated by the modified Zuber-Staub l

model. The AP600 film stability model bounds the breakdown flow rate of subcooled films on l

the prototypical surface.

i l

The modified Zuber-Staub film stability model was compared with published subcooled film j

breakdown data on other surfaces. Fujita and Ueda (Ref. 8.13) and Bohn and Davis (Ref. 8.14) measured the breakdown of subcooled water films.on heated, vertical, polished, stainless steel l

tubes.~ A wide range of film flow rates and heat fluxes was covered; the subcooled fdm j

temperatures were between 70 and 170*F. The minimum stable film Re number calculated by the AP600 film stability model, using a 65* advancing contact angle for stainless steel (Ref.

8.18), was compared with this data set. The results are shown in Figure 8-9.

I A comparison of the range of subcooled film Re numbers at breakdown between the polished, vertical, stainless steel tube surface and the prototypical inorganic zinc coated surface (Figures 1

8-8 and 8-9) shows that the subcooled film remains stable at much lower flow rates on the inorganic zinc coated surface over the same range of heat fluxes. The stainless steel and copper surfaces, typically used in film stability studies, do not wet well and consequently are expected l

to exhibit less stable films than the inorganic zine coating on the AP600 containment shell.

Therefore, it is important and appropriate to use fdm stability data from the prototypic surface to validate the AP600 film stability model.

All three data sets show the modified Zuber-Staub film stability model is relatively insensitive to heat flux in the range of the subcooled film test data. At higher heat fluxes, the model predicts stable dry patches will be formed at lower Re numbers than were measured in the tests:

l and at lower heat fluxes, the model predicts stable dry patches will be formed at higher Re number than were measured in the' tests.

4 l

i l

It is quite clear that the modified Zuber-Staub film stability model does not predict the subcooled film breakdown data for either the prototypical surface or the stainless steel tubes. One approach to force the model to better correlate the subcooled film breakdown data is to apply a multiplier to the thermocapillary term in the model. Another approach is to apply a multiplier to the prediction of the minimum stable subcooled film flow rate and bound all of the test data from i

the prototypical surface over the entire heat flux range of interest.

This second, more l

conservative, approach has been chosen for the AP600 film stability model.

28

~

r 1-

O Bm u kn$DaoCg ?om:

2o~M i

,E 3 5PO' 0 $

^

0 3

5 2

)

2 x-t f

-r 2

U h

/

0 T

x x B

(

y x

m.

n w

o d

k 5

a 1 s e a r

/

aB n

A**

s u

ot n a i

m x

u l

0 F

1 E

y t

a e

a.

H Mm

, 5 d

ie e

s i

a t

w a

m.

m i

o t

e

  • m

,m s

E M

=

0 0

0 0

0 o

0 0

0 0

0 5

0 5

2 1

1 C3oyyeGLO #O L aZ GE E

_1 U.pOE $m

r B yr.E.< $OC1m k::

Oo3m 'mCDo".3o $Osmmn NC7"?vg g go > 3 8 2

75Ca***

E

~v)H uC7fc"5c*T.B Wnkc.o5D ope 1

n t

aC t

m

!i

Westinghouse Proprietary Class 3 Preliminary Draft l

l R

x x

O

- p

  • Y
  • x

/

g x

m s

m a

x x s

a 5

h x

0 c

e s

$3 0

m se 5v 2

x r X a

E j

O "m

E l

  • g o e

i mi

~

t 1

3 Il l

S j

i O

s O

1 1

0 x

i i

i i

i i

i i

o m

e m

e e

v m

N e

o l

smesnwi 1

umopMusJG 4Q JequanN ed uJ t ! y pa l ocoqng Figure 8 Comparison of the Modified Zuber-Staub Film Stability Model with Other Subcooled Film Breakdown Data 30 l

l

i t

Westinghouse Proprietary Class 3

)

Preliminary Draft j

The value for a bounding subcooled film stability multiplier, R,,,, was obtained using the film L

coverage test data from the unheated, full-scale Water Distribution Tests and the heated 1/8-scale l

Large Scale Tests.

Because prototypical test data was used R,,, includes the effects of l

subcooling, plate misalignment and the method of film application on the initial film splitting l

behavior. The following method was used to determine the bounding R,,, value.

l 1.

The modified Zuber-Staub film stability model was used with: a contact angle of [

}",

the measured peak dome heat flux, the initial flow rate at the point of application, and the initial water temperature to determine a maximum value for F..

2.

The C., value was multiplied by R,,, to determine the dome circumference, Cl, at which the average film flow rate became unstable.

)

1 3.

The wetted coverage (width of the film stripes) at the circumference of the vessel springline, CSL, was predicted using the following approximation:

WDL = (Cl + CSL)/2 4.

The predicted film coverage at the springline was compared with the measured film coverage and the R,,, value was varied until all of the data was bounded. Note, the film coverage was measured at the vessel gutter, not at the springline in the Large Scale Tests.

Since the widths of the film stripes were observed to remain relatively constant from the springline down to the point of measurement (at the vessel gutter), the same coverage was assumed at the springline.

Using a higher film contact angle or lower film temperatum in step 1 above would cause the F,,

(

value to increase, however, this would force the bounding R,,, value to be lower (since the test data is bounded by the product of F., and R,,,).

Therefore, this method for determining the bounding coverage at the vessel springline is conservative at any contact angle.

This approach yields a bounding R,,, value of (

]". The results are shown in Figure 810. The ratio of the predicted-to-measured film coverage is shown as a function of the maximum heat flux in Figure 8-11. This shows that this method for determining the initial sidewall coverage-bounds the ' measured test coverage values over a larger range of heat flux than is expected on the AP600 shell during a DBA.

i a

i 9

l 1

31

Westinghouse Proprietary Class 3 Preliminary Draft

- %O t

I e

i

\\

l i

I 1

Figure 8-10 Bounded Water Coverage Data 32

1 Westinghouse Proprietary Class 3 Preliminary Draft I

c), L I

l t

t i

l t

t

)

i 1

1 L

1 Figure 8 Bounded Test Coverage Data as e Function of Heat Flux 33

]

Westinghouse Proprietary Class 3 Preliminary Draft 8.5 The AP600 Containment DBA Evaluation Model Film Coverage Input The shell evaporation rate is a function of the shell heat flux, wetted perimeter and film flow rate, all of which are interdependent and vary with time and position. The heat Oux to the shell is dependent on the mass and energy release rate and the condensation rate. The shell heat flux decreases with time and increases with increasing elevation. The gravity driven water flow rate is dependent on the standpipe design and the head of water in the storage tank, and decreases l,

with time as the storage tank drains. The film flow rate and wetted perimeter decrease with time and change with elevation as spreading and evaporation occur.

t The containment DBA evaluation model requires an input water flow rate along with elevation i

dependent water coverage area and wetted perimeter input values to compute the evaporation rate l

from the shell. Because'the evalunion model uses constant values for the water coverage area l

and wetted perimeter input at each elevation, the water flow rate input must account for changes l

in the evaporation rate with time.

An 1I minute delay in the application of the PCS Dow is assumed. This delay is based. on the maximum time required to reach steady state coverage for a PCS flow rate of 220 gpm (as i

determined by the Water Distribution Tests and described in Section 8.3). An estimate of the conservatism in this assumed delay time is provided in Section 8.6.3.

Water that does not evaporate on the shell will runoff. The amount of runoff will increase as

]

the shell heat flux and coverage decrease.

The AP600 film stability model is used to l

conservatively calculate a maximum runoff amount. This runoff amount is subtracted from the gravity driven water flow rate and the result is input to the WGOTHIC evaluation model. The method and assumptions that are used to calculate the flow rate input are described in the sample 1 calculation that follows.

l 8.5.1 Sample PCS Film Flow Rate Calculation The gravity driven PCS film flow rate is conservatively calculated assuming one of two parallel l

valves in the PCS piping fails to open. An example is shown in Figure 8-3.

l The AP600 film stability model is used to calculate a bounding value for the minimum stable l

film flow rate, I'.. The minimum stable film flow rate is shown in Figure 8-12 as a function l

of heat Oux assuming film temperatures of 200 and 120*F (the initial film temperature) and a l

contact angle of [

]". The value selected [

l". bounds film temperatures greater 2

l than 120*F and heat fluxes up to 10000 BTU /hr-ft,p, To calculate a conservative ~ maximum runoff flow rate, assumptions are made to minimize the wetted perimeter and maximize the film now rate at the vessel springline. To minimize the wetted perimeter at the springline, ignore the re-distribution effect of the weirs. To maximize the film How rate at the springline, assume the film does not evaporate on the dome.

j 34 l

I I

Westinghouse Proprietary Class 3 Preliminary Draft

-Q,d f

+

[

i t

i 1

[

l i

t I

l l

l s,

Figure 812 - Minimum Stable Film Flow Rates Predicted by the Zuber-Staub Model Showing Sensitivity to Heat Flux and Film Temperature at a [ ] Wetting Angle a

e 35

Westinghouse Proprietary Class 3 Preliminary Draft The wetted perimeter at the springline is calculated by first determining the point on the dome where the film is predicted to become unstable M PCS

  1. " 2nR,,p.

The wetted perimeter at the springline is given by the minimum of the vessel circumference, 2nr,,,,,, and Pm - x(r p + r _ p The film evaporates as it flows down the vertical sidewall, causing F to decrease. The sidewall evaporative. heat flux decreases as the film travels downward. A conservatively low value for the average sidewall evaporative heat flux, Q,", is used to minimize the evaporation rate and maximize the amount of film that is calculated to run off the surface. If the average sidewall evaporative heat flux calculated by the evaluation' model is less than the assumed value, the runoff amount is recalculated using the lower heat flux value and a new film flow rate is input to the evaluation model.

In the PCS tests, the film was observed to continue to thin while maintaining a relatively constant width until it was completely evaporated. For the calculation, the wetted perimeter of the evaporating film is assumed to remain constant until evaporation thins the film to a value equal to the minimum film flow rate predicted by the AP600 film stability model. The distance down the vertical sidewall at which the film reaches the stability limit, r,,, is calculated as the minimum of

~

k Z

OYuemad and the sidewall height.

From this point on, the wetted perimeter is assumed to decmase as the film continues to evaporate at the constant stability limit, r...

Using this assumption, the rate of change of the film flow rate with height is related to the evaporation rate r*D - r~N de h,

l r

36

Westinghouse Proprietary Class 3 Preliminary Draft l

Solving for P(z) gives the exponential function P(z) = Pm eWh The runoff Gow rate at the bottom, Z,,, is is

-pg g4W-Ud Alternatively, if the wetted perimeter is assumed to remain constant as the film evaporates on the vertical sidewall (more consistent with the PCS test observations), the change of the film flow rate with height would be

$=Y N

and the runoff flow rate at the bottom would be Q"zPw 54=km-This alternative approach results in less runoff flow, as shown in Figure 8-13. Therefore, the assumption that the film evaporates at a constant minimum stable film flow rate is more conservative.

The difference of the gravity driven PCS flow rate and the nmoff flow rate is input to the AP600 containment DBA evaluation model. The calculations are summarized in Table 8-9.

l l

l 37

Westinghouse Proprietary Class 3 Preliminary Draft O

9 no 8

8 n[

R Co a

0 g

2mm<

I A

C L O.

.O O

oo e c

- a 2.f1 p

m a v

. g g

g9 t

.E m o o

m c.

H U

n o B

P, 8$

a a C

C o

e a a aq

~

0 f

88 o o

?

N -_

T: _

s p

o O

g c

e Cs /wA13 825d

  • Id 44 #d Figure 8 Comparison of Predicted Runoff Flow Rates 38

Westinghouse Proprietary Class 3 Preliminary Draft i

l

- cl L

/

I I

i M

II

t

?

)

s W

~l!

w I

C w

O w

.4 a

1 O.

,9 t

k a

9 1

4

?

Y I

O v.

T 4

9 U

6 asse ans b

l i

I J

1 i

P i

F

'M og I

l 39 i

i I

i i

Westinghouse Proprietary Class 3 l

Preliminary Draft l

l 8.5.2 Coverage Area and Wetted Perimeter Inputs All of the PCS film flow input to the containment DBA evaluation model should be evaporated since the predicted runoff flow rate has been maximized and subtracted from the gravity driven PCS flow rate. Therefore, the coverage area and wetted perimeter inputs to the evaluation model should be maximized to prevent runoff.

The coverage area and wetted perimeter 'aput values for the evaluation model are based on the measured water coverage values from the unheated, phase 3 Water Distribution Tests. The coverage. area percentage values listed below represent the measurements at the 27.5 gpm flow i

rate (which is equivalent to a 220 gpm flow rate on the AP600).

Clime Percentage Location 1

[ ]"

(Top of dome to first weir) 2

[ ]"

(Dome - between first and second weirs) 3

[ ]"

(Dome - second weir to top of vertical sidewall) 4-7

[ ]"

(Sidewall)

The coverage value for the top of the dome down to the first weir is estimated from the video tapes of the tests. The coverage area and wetted perimeter change significantly over the diverging area between the first and second wein. The coverage value for this region is based on the minimum measured value just above the second weir. The coverage area and wetted perimeter do not change much over the nearly vertical region between the second weir and the top of the vertical sidewall. The coverage value for this region is based on the measured value at the springline. Based on observations from the heated large scale tests, the coverage area and wetted perimeter are assumed to remain constant down the vertical sidewall.

8.5.3 Summary of Bounding Assumptions and Conservatisms The following list of the bounding assumptions and coriservatisms in the method for determining the AP600 containment DBA evaluation model is provided for reference.

1.

The gravity driven PCS flow rate is calculated assuming a single failure of one of two parallel valves in the PCS piping (Section 8.2.6). This reduces the amount of the initial water flow rate available for evaporation from the shell by about 2E 2.

A water coverage delay time is used to account for filling of the weirs and establishing steady state water coverage (Section 8.3).

This neglects energy removal from the containment during the initial water coverage transient. A conservative estimate of the l

amount is given in Section 8.6.3.

3.

The initial (applied) film temperature is assumed to be at the maximum allowable value to minimize the amount of sensible heat removal by the film.

40

l.- -

---.~.

l Westinghouse Proprietary Class 3 Preliminary Draft l

4.

The AP600 film stability model is based on a model for predicting the stability of a postulated dry spot (Section 8.4). Since film stability increases as the film temperature i

increases, the minimum stable film flow rate is calculated assuming the film remains at

[

the initial (applied) temperr.ture. Comparisons with test data for stable, evaporating films i

show that the stability model over-predicts the minimum measured stable film flow rates by at least a factor of 2. Comparisons with test data for subcooled films show that the stability model under-predicts the minimum stable film flow rate as the heat flax increases. A multiplier is applied to predict the breakdown of subcooled films on the E

dome. The value of this multiplier was determined by bounding all of the available PCS film coverage test data over a range of heat flux that is more than twice the estimated i

peak'value during a DBA LOCA event.

l 5.

The ' contact angle that is used as input to the AP600 film stability model is based on the l

maximum measured steady state value for a heated, weathered surface (Section 8.4.2).

l 6.

The AP600 film stability model is used to estimate the maximum amount of runoff flow from the shell (Section 8.5.1). The redistribution effect of the weirs and the heatup and l

evaporation of the applied film are neglected in estimating the wetted perimeter and film l

flow rate at the springline. Contrary to test observations, the width of the film stripes is assumed to decrease while maintaining the predicted minimum stable film flow rate as the film evaporates on the vertical sidewall. A low estimate of the sidewall average evaporative heat flux is used to minimize the evaporation and maximize the predicted runoff flow.

-l 7.

The difference between the minimum gravity driven PCS flow rate and the maximum' j

predicted runoff flow rate is input to the AP600 containment DBA evaluation model.

t L

i 41

l I

Westinghouse Proprietary Class 3 Preliminary Draft 8.6 AP600 Containment DBA Evaluation Model Film Coverage Sensitivities Sensitivitiy analyses perfomied with the AP600 containment DBA evaluation model are provided l

in this section. The models sensitivity to the location of water coverage and PCS film flow rate input are provided. An estimate of the conservatism in the assumed time delay for PCS film l

application is also provided.

8.6.1 Sensitivity of the Evaluation Model to the Location of Water Coverage Calculations were performed with the WGOTHIC code to determine if the evaluation model was sensitive to the location of the water coverage. Three cases were examined. In the first case, PCS water was applied to the dome portion of the shell; in the second case, PCS water was applied to the wall portion of the shell, and in the third case, PCS water was applied to one hemisphere of the dome and wall. The input PCS water flow rate was selected to be smal~.1 enough to prevent any mnoff flow from the ' minimum surface area of the three test cases. The input PCS water flow rate was maintained at the same fixed value for each case.

l Figure 8 14 compares the pressure transients for the three sensitivity cases, and clearly illustrates j

the insensitivity to the location of evaporation in the evaluation model. Since the input PCS flow rate is based on a conservative estimate of the evaporation rate, the coverage area input can be 4

any value that is large enough to completely evaporate all of the flow, preventing mnoff from the shell. Therefore, using coverage area input values that are based on measurements from the unheated Water Distribution Tests is reasonable.

j 42 l

Westinghouse Proprietary Class 3 Preliminary Draft o

8

ci

=

~

i$

I 6e 6 !

o 8

Y9 ;;

4

~

ai 7

=

n xE o' o O

" "g i$

=

o l

?

l 2

i=

3 2.

CL.

~

xE O

_ o o

E b

a

?=

i

~

E<

i i

O o

o O

O tO sn M

C3 N

(etsd) eJnsseJd Figure 8 Coverage Area Sensitivity Case Comparison of Transient Pressure 43 I

l l

Westinghouse Proprietary Class 3 Preliminary Draft I

i 8.6.2 Sensitivity of the Evaluation Model to the Input PCS Film Flow Rate l

i l

Calculations were performed using the WGOTHIC code to determine the sensitivity of the evaluation model to the input PCS film flow rate. The nominal input PCS film flow rate was conservatively calculated, as described in Section 8.5.1.

The input PCS film flow rate was increased in 10% increments from this nominal value. The time of film application was adjusted in each case to account for the increased film flow rate since the time it takes to fill the headers j

and weirs is inversely proponional to the film flow rate. Note, the time to reach steady state l

coverage after the weirs are filled (5 minutes) was conservatively assumed to be independent of the film flow rate. The coverage area and wetted perimeter input values were kept the same for each case.

Figure 8-15' presents the' change in peak containment pressure as a function of the normalized change in PCS flow rate. The peak containment pressure decreases as the PCS flow rate increases from the nominal value. Incmasing the PCS film flow rate does two things: it reduces the time of film application and increases the amount of evaporation from the shell. Eventually, the evaporation rate reaches a maximum value and water begins to run off the shell.without evaporating. Further increases in the PCS flow rate result in diminishing reductions in the peak containment pressure.

1

.u

Westinghouse Proprietary Class 3 Preliminary Draft AP600 - Water Film Flowrote Sensitivities PCS Flow Rote Sensitivity 0

m o.

~

.2 u

a m

m e

L o-

.4 C

E C

.6

\\

o

\\

C oa u

.s o

o o_

C x

\\

e T

N O

.c O

-1 2 1

1.2 1.4 1.6 1.8 2

Normalized PCS Flow Rate Figure 8 Sensitivity to the Input PCS Film Flow Rate 45

Westinghouse Proprietary Class 3 Preliminary Draft 8.6.3 Conservatism in the Assumed Time Delay for Application of the PCS Film l

A delay in application of the PCS film is assumed in the DBA evaluation model to cover the time it takes to fill the weirs and establish a steady state coverage, as described in Section 8.3.

l The coverage delay time is conservative in that it neglects energy removal from the shell while j

l steady state film coverage is being developed. An assessment of the amount of conservatism in the predicted energy removal is provided in the calculations that follow.

l To quantify the amount of energy removal neglected during the development of steady state film l

coverage, the WGOTHIC case described in Section 8.3 was extended out to 1800 seconds. The shell temperature and heat removal results from this case were compared to the results from a second case in which the assumed water coverage delay time (for the top of the dome) was

~

reduced to a more realistic value. For the base case, the water film was applied at 660 secorids and for the second case, the water film was applied at 60 seconds. The same input water coverage fractions were used in both cases.

l l

Note, the WGOTHIC code assumes steady state water coverage develops instantaneously at the.

~

time the film is applied, i.e the time required to fill the weirs and develop steady state coverage with the 220 gpm water flow rate is bounded by the assumed 660 second time delay in application of the film. Although the second case, with a more realistic estimate of the film-l,

  • application delay time for the top of the dome, will give a more accurate estimate,of the hegt removal from the top portion of the dome,it will overestimate heat removal from the rest of the dome and sidewall since the code does not model the time required to fill the weirs and establish the steady state water coverage. Therefore, only the heat mmoval from the top of the dome will be compared to give a minimum value for the heat removal neglected.

.The transient inner and outer shell temperatures of the wet portion on the top of dome down to the first weir for both assumed PCS delay times are shown in Figure 8-16. The wet outer shell

]

temperature increases to only about 165*F in the more accurate,60 second delay case. It is also j

interesting to note that about 5 minutes after water is applied iri the 660 second delay case, the wet shell temperatures decrease to about the same values as the 60 second water coverage delay case and that the difference in the coverage delay time doesn't seem to have much impact on the containment temperature.

The transient inner and outer shell temperatures for the wet and dry areas at the top of the dome for the 60 second delay case are shown in Figure 8-17. WGOTHIC models 1-D conduction (through the shell) so conduction between the wet and dry areas is neglected. If azimuthal conduction were modeled, the temperature of the dry area would be lower and the temperature of the wet area would be higher. More water would be evaporated at the. higher elevations so the amount predicted to reach the lower elevations (or runoff the shell) over time would be lower.

Therefore, the use of a 1 D conduction model in the evaluation model results in a higher l

predicted runoff flow rate and reduces the amount of evaporative heat removal from the shell.

46

h Westinghouse Proprietary Class 3 Preliminary Draft Figures 8-18 and 8-19 compare the transient and integrated energy removal rate from the top of i

the dome as a function of time. There is very little difference in the energy removal rates for the first 300 seconds (due to the relatively long time constant of the shell), but the earlier application of the water film does significantly increase heat removal after 300 seconds. The heat removal rate for the 660 second delay case increases rapidly after the liquid film is applied and i

matches the heat removal rate of the 60 second delay case about 5 minutes later. Approximately 350,000 BTUs more energy is absorbed by the top portion of the dome due to the earlier application of water on the dome.

The energy release frorn the lower po'rtions of the dome and sidewalls (if it could be calculated with the proper weir fill delay times) would cause this value to increase significantly. As an estimae, u.:wme that all of the film applied after the first 5 minutes evaporates without running off he shell. With this assumption, an additional 10,900,000 BTUs would be absorbed from the shel. If this same amount were assumed to be removed from the containment atmosphere, it would correspond to approximately a 2 psi decrease in the peak containment pressure.

Therefore, the assumed water coverage delay time conservatively neglects the energy removal from containment during the initial water coverage transient.

l

)

O l

4 47

Westinghouse Proprietary Class 3 Preliminary Draft i

i I

I l

O 8

~

ll>

<l(

Ci(

j ll>

<lf (lC 4

1 j

j

<n (lC ni l

{

5 ll>

<ll

( (

g 8

i 5

lle

<>l (lC l

l up

<n (lC

<i x

n, (i(

uk

<l)

(lC n

ll>

<l I

()(

0 I

a o V e

- 8.c 3

g ni t r m

8 g

e a>

5 s

M i

ni 0

"a v

g 3

a b

4 1

i w

O ()

ll F i

l l >

1 i!

e s

i t

I

~

4 3

i n

n 4

o 8

8 8

8 8

m a

~

c c

(d) aan1GJadwal l

l l

Figure 8 Comparison of Wet Shell Temperatures at Top of Dome j

(with PCS Film Applied at 60 and 660 Seconds) 48

Westinghouse Proprietary Class 3 Preliminary Draft 4

8 8

a) u x

41 )

n x

III) n x

s n

ol) n x

1 o

8 C

oly n

x i

3 inl) n x

e 3

in<D n

X y

);

)

o n

5' U) a 1i f

o u 1

- 88 i

o 3,

"u a

+

e 1

x t

3 o<

o 8

1 i

O O e

R g

1 a

i s

i 1

i o

n 4

O 8

8, 8

8 8

m n

~

e (d) eJn2eaedwei Figure 8 Comparison of Wet and Dry Shell Temperatures at Top of Dome (with PCS Film Applied at 60 seconds) 49

i Westinghouse Proprietary Class 3 l

Preliminary Draft I

i S

R 15 15

'l IP ll

- S l

B 1 5 1 >

QU M

C D

l O

C U

O O

U A

Q 0

O W

o

- 8 D o

C D Q e

O w a U

O 9

9 W

d d

L./

D D

0 0

0 E

O O Q

~

o L

L 0

0 a

a d

d 3

3 ll 16 O

i i

i i

i i

i i

o en a

n a

e w

m n

e o

r SpuGSncyl Cs/nie3 ewoo os pes;easua;1 x6;eug l

l Figure 8 Comparison of Energy Transferred at the Top of Dome j

(with PCS Film Applied at 60 and 660 Seconds) 50

l _

l I

l Westinghouse Proprietary Class 3 l

Preliminary Draft I

o 8~

l l\\

i l

l 8

C 1

l mV L9 C

U O

C U

O e

U n

e o

i

_ 8$o c

l s

e o O

e e j

o a

a m

o o

l V t

.b

.3 a a a

a L

L

- 8 e

o n

s a

t e

o t

i 3

3.

I 11 lb l

l t

t i

f I

I I

b g e

n e

n e

m

~

e a

suo n i m (nie) ewoO 01 DeJJegsuaal X6;eug pele;6elui Figure 8 Difference in the Integrated Energy Transferred to the Top of the Dome (with PCS Film Applied at 60 and 660 Seconds) 51 l

1

4 Westinghouse Proprietary Class 3 l

Preliminary Draft i

f l

8.7 Summary The range of the PCS film coverage test data parameters is tabulated and compared with the l

estimated range for the AP600 during a DBA. It is important for the test data to bound the j

l maximum expected heat flux, minimum sidewall Re number and the minimum expected film l

m temperature for evaluating the film stability model since the film is less stable at higher heat flux.

I lower film temperatures and lower flow rates. The test data bounds the expected range of the i

AP600 film parameters and is sufficient for evaluating the film stability model.

l The PCS tests show that the applied water film is able to wet and rewet a hot surface l

l (temperat'ure exceeding 240*F) painted with the inorganic zine coating to be used on the AP600 l

containment shell. Calculations of the AP600 shell temperature response, during the 10 minute time period to establish steady state water coverage, show the dry, external shell surface temperature will increase by less than 10*F at the time water first reaches the shell, by-less than 50*F at the time the first weir fills and begins to spill, and by less than 70*F at the time the second weir fills and begins to spill, l

A modified form of the Zuber-Staub model (for determining dry spot stability) is used to i

conservatively estimate a maximum value for the minimum stable film flow rate. The sensitivity of the model to contact angle, film temperature and heat flux is presented. The minimum stable film flow rate predicted by the model decreases with increasing film temperature. He minimum stable film flow rate is not sensitive to heat flux at the measured contact angle for the inorganic zine surface.

1 i

Measurements of the film contact angle show the wettability of the inorganic zine surface improves as it oxidizes with age. The effect of surface contamination on wettability cannot be accurately quantified, so in-service inspection and cleaning procedures will be developed to maintain surface wettability above an acceptable minimum level.

)

i

, Comparisons with test data on the prototypical inorganic-zinc coated surface show the AP600 film stability model conservatively over-predicts the minimum stable film flow rates measured on the vertical test section. A multiplier, which is determined by bounding test data from the unheated Water Distribution Tests and the heated baseline and Phase 2 Large Scale Tests, is applied to the model prediction of the minimum stable film flow rate to conservatively account for subcooled film breakdown on the AP600 dome surface.

The input film flow rate is calculated to minimize the evaporation rate in the DBA evaluation model.- A conservatively high film runoff flow rate is calculated using the AP600 film stability model. The difference between the gravity driven PCS flow rate and the runoff flow rate is input to th'e evaluation model. A sample calculation is provided'to illustrate the method.

j The AP600 containment DBA evaluation model is shown to be insensitive to the location of evaporation (i.e., coverage area) for a given PCS film flow rate. Derefore, the film coverage area mput is based on the measured coverage fractions from the Water Distribution Tests.

i 52 I,

Westinghouse Proprietary Class 3 Preliminary Draft References l

8.1 A. T. Pieczynski, W. A. Stewan, WCAP-13884, " Water Film Formation on AP600 l-Reactor Containment Surface", February 1988 l

8.2 J. E. Gilmore, WCAP-13960, "PCS Water Distribution Phase 3 Test Data Report".

l December 1993 1

8.3 W. A. Stewan, A. T. Pieczynski, L. E. Conway, WCAP-12665 Rev 1. " Tests of Heat Transfer and Water Film Evaporation on a Heated Plate Simulating Cooling of the AP600 Reactpr Containment", April 1992 j

8.4 R. E. Batiste, WCAP-14134, "AP600 Passive Containment Cooling System Integral l

' Small-scale Tests Final Report", August 1994 8.6 F. E. Peters, WCAP-13566, "AP6001/8th Large Scale Passive Containment Cooling System Heat Transfer Test Baseline Data Report", October 1992 8.7 F. E. Peters, WCAP-14135, " Final Data Repon for PCS Large-Scale Tests, Phase 2 and Phase 3", July 1994 D. R. Spencer, Enclosure 2 to Westinghouse Letter NTD-NRC-94-4100, " Liquid Filln l.

8.8 Model Validation", January 1994 8.9 D. R. Spencer, WCAP-1,4190, " Scaling Analysis for AP600 Passive Containment Cooling System", October 1994 8.10 Frank Kreith, " Principles of Heat Transfer",3rd Edition,1973 8.1 I W. S. Norman and V. McIntyre, " Heat Transfer to a Liquid Film on a Vertical Surface",

i Trans. Inst. Chem. Engrs Vol. 38, pp301-307 (1960) 8.12 V. A. Hallett, " Surface Phenomena Causing Breakdown of Falling Liquid Films During i

Heat Transfer", International Journal of Heat and Mass Transfer, Vol. 9. pp 283-294 (1966) l l

8.13 T. Fujita and T. Ueda, " Heat Transfer to Falling Liquid Films and Film breakdown Parts 1'

I and II", International Journal of Heat and Mass Transfer, Vol. 21, pp 97-108 and 109-118 (1978) 8.14 M. S. Bohn and S. H. Davis, "Thermocapillary breakdown of Falling Liquid Films at j

High Reynolds Numbers", International Journal of Heat and Mass Transfer, Vol. 36, pp i

1875-1881 (1993) 53

Westinghouse Proprietary Class 3 Preliminary Draft 8.15 S. G. Bankoff, " Dynamics and Stability of Thin Heated Liquid Films" Transactions of the ASME - Journal of Heat Transfer, Vol. I12, pp 538-546. (1990).

8.16 N. Zuber and F. W. Staub!" Stability of Dry Patches Forming in Liquid Films Flowing over Heated Surfaces". international Journal of Heat and Mass Transfer, Vol. 9, pp 897-905 (1966) 8.17 R. Wright, PCS-GSR-003, "A Method for Determining Film Flow Coverage for the AP600 Passive Containment Cooling System", July 1994 8.18 A. B. Ponter, G. A. Davies, T. K. Ross and P. G. Thornley, "The influence of Mass Transfer on Liquid Film Breakdown", International Journal of Heat and Mass Transfer, Vol'10, pp 349 -359 (1966) l 1

j l

f l

54