JAFP-85-0226, Monthly Operating Rept for Feb 1985

From kanterella
(Redirected from ML20112A321)
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1985
ML20112A321
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/28/1985
From: Jackie Cook, Glovier H
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF ADMINISTRATION (ADM), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
JAFP-85-0226, JAFP-85-226, NUDOCS 8503180257
Download: ML20112A321 (11)


Text

__

.,. .g OPERATING DATA REPORT DOCKET NO. 50-333 DATE Mar 1985 COMPLETED hy J. Cook TELEPHONE (315)342-3840

_0PERATING STATUS

1. Unit Name: FitzPatrick  : Notes  :
2. Reporting Period: 850201 - 850228  :  :
3. Licensed Thermal Power (MWt): 2436  :  :
4. Nameplate Rating (Gross MWe): 883  :  :
5. Design Electrical Rating (Net MWe): 821  :  :
6. Maximum Dependable Capacity (Gross MWe): 830  :  :
7. Maximum Dependable Capacity (Net MWe): ~B10
8. If Changes occur in Capacity Ratings (Items 3 Through 7) Since Last Report,Give Reasons:

NONE

9. Power Level To Which Restricted, If Any (Net MWe): NONE
10. Reasons For Restrictions, If Any:

This Month Yr.-to-Date Cumulative

11. Hours In Reporting Period 672 1416 84097
12. Number Of Hours Reactor Was Critical 352.8 1096.8 00/12.5
13. Reactor Reserve Shutdown Hours 0 0 u
14. Hours Generator On-Line 352.8 1096.5 39U44.1
15. Unit Reserve Shutdown Hours 0 0 u
16. Cross Thermal Energy Generated (MWH) 836136 2555532 123494/50
17. Gross Electrical Energy Generated (MWH) 286010 8/3930 43134ziu
18. Net Electrical Energy Generated (MWH) 276710 845655 412436/U
19. Unit Service Factor 52.5% 77.5% 70.2%
20. Unit Availability Factor 52.5% 77.5% /U.2%
21. Unit Capacity Factor (Using MDC Net) 50.8% 73.7% 63./A
22. Unit Capacity Factor (Using DER Net) 50.2% 72.7% 59.7%
23. Unit Forced Outage Rate 0% 0% 13.3%
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
25. If Shut Down At End Of Report Period. Estinated Date of Startup: May 6, 1985
26. Units In Test Status (Prior to Commercial Operation): Forecast Achieved INITIAL CRITICALITY INITIA!. ELECTRICITY COMMERCIAL OPERATION 8503100257 850228 PDR ADOCK 05000333 R PDR

AVERAGE DAILY UNIT POWER LEVEL

, DOCKET NO. 50-333 --

UNIT FitzPatrick DATE March 1985 l

COMPLETED BY J. Cook TELEPHONE (315)342-3840 MONTH February 1985 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 713 17 -

2 802 18 -

4 3 802 19 -

l 4 804 20 -

5 801 21 -

6 802 22 -

7 793 23 -

4 8 791 24 -

9 788 25 -

10 787 26 -

11 777 27 -

12 771 28 -

13 767 29 -

14 530 30 -

15 -

31 -

16 - -

SUMMARY

The FitzPatrick Plant operated at near full thermal power until f

850214 when the unit was shutdown for refueling.

i .

. . .. , - . - - - ~_ _ - .. - - -

., <.,s i

4 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE i

FEBRUARY 1985 The FitzPatrick plant operated at near full' thermal power for the first j fourteen days of this reporting period. On February 14, 1985, the unit.

was shutdown for refueling ending cycle 6. During the shutdown while testing the turbine load unbalance circuitry, a mispositioned pressure

! transmitter isolation valve caused an' initiate signal which ultimately scrammed the plant. An evaluation for cause and corrective action =has been initiated. (See LER-85-006).

At the end of the reporting period, the FitzPatrick plant-is shutdown with startup scheduled to commence May 6, 1985.

1 4

t i

i 1

6 s

l l

J i

l i

I l

l i

i

t UNIT SilUTDOWSS AND F0WER-REDUCTIONS DOCKET NO. '

UNIT NAME DATE REPORT MONTH COMPLETED BY TELEPHONE l "

x xoo R e 3G 7w z $d LICENSEE S'is CAUSE & CORRECTIVE l' NO. DATE E' "$ 8 $U# EVENT $$ $$ ACTION TO

$ $ d is S $ REPORT # $" @. " PREVENT RECURRENCE ov x gmg 8 3 850214 S 319.2 C 3 85-006 TB N/A SHUTDOWN FOR REFUELING (cumulative hrs. 319.2) l SEE NARRATIVE

SUMMARY

1 i

2 3 4 1

F: Forced Reason: Method: Exhibit G. Instructions S: Scheduled A-Equipment Failure (E : plain) 1-Manual for Peparation of Data B-Maintenance of Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File NUREG D-Regulatory Restriction 4-Other(h. plain) 0161 E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)

H-Other(Explain)

)

NEW YORK POWER AUTHORITY - JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE

SUMMARY

FEBRUARY 1985 ACTION TAKEM REPAIR WORK REOUEST NO. HOW CAUSE OF RESULTS OF 10 PRECLUDE TIME DATE SYSTEM CO"PONENT NO. DETECTED MALFUNCTION MALFUNCTION RErURRENCE HOURS 850207 02-3 023108 JIC AGE GEARS WEARING / REPLACED C-13, CLEANED 5.0 TR-89 PRINT MECH CHART GEARS PROBLEM 850226 03 035577 OPS STICKY SWITCHES SCRAM LTS ON 09-5 CLEANED SWITCH 3.0 ROD 38-43 LACK OF USE FULL DISPLAY ACTUATORS / CHECKED OK 850219 03 027962 OPS N/A RETEST CERTAIN RODS PERFORMED IMP-3.7/ 4.0 ROD INDIC. FAILED FULL INDIC OK-TRANS TO MAINT.

850218 03 034496 OPS AGE R0D SPURIOUSLY REPLACED SWITCH / 8.0 ROD 34-37 DESELECTS ITSELF TESTED OK 850206 03 034490 OPS UNKNOWN RED & GREEN LTS ON PERFORMED IMP-3.7/ 1.5 ROD 06-19 AT SAME TIME PROBLEM DISAPPEARS 850130 03 034489 OPS WEAR / AGE NO CHART ADVANCE / REPLACED PEN AMP, 6.0 FR-528 NO BLACK PEN REPAIRED LOOSE GEAR 850218 03-800 034643 OPS AGE SELECT BUTTON NOT REPLACED SWITCH / 8.0 ROD 38-23 OPERATING PROPERLY TESTED OK 850213 07 023156 JIC DIRTY GEARS ON SLUGGISH RESPONSE CLEANED GEARS /RAN 1.5 R-45 RECORDER IMP-G14

NEW YORK F0WER AITTHORITY - JAMES A. FITZPATRICK NUCLEAR POWER PLANT s'

MAINTENANCE

SUMMARY

FEBRUARY 1985 ACTION TAKEN REPAIR WORK REOUEST NO. HOW CAUSE OF RESULTS OF 'IO PRECLUDE TIME DATE SYSTEM CO"PONENT NO. DETECTED MALFI'NCTION MALFUNCTION PErURRENCE HOURS 850212 07 034487 OPS UNKNOWN SELECT SWITCH WILL CHECKED SWITCH AND 16.0 ROD 34-19 NOT WORK FOR B RBH RELAY /0K 840214 11 034625 OPS PARTIALLY PLUGGED DISCREPENCY-METER PERFORMED ISP-82, 9.0 LI-66 SENSING LINE AND DIPSTICK ADJ TRANSMITTER ZERO AND SPAN 850206 16-1 034610 OPS RECORDER OUT RECORDER READING CALIBRATED RECORDER 18.0 DPR-200 0F CALIBRATION LOWER THAN PER ISP-35 COMPUTER 850131 17 034528 ops OUT OF CALIBRATION "A" SIDE READING CALIBRATED BLACK PEN / 10.0 RR-433 ERRATIC CLEAN SLIDEWIRE 850220 23 034640 OPS SWITCH FLOAT INDICATES OPEN SWITCH TO BE REPLACED 8.0 A0V-53 ASSEMBLY WHEN FULLY DRND BY MAINTENANCE 850216 23 023046 JIC AGE-DAMAGE INSTRUMENTS REPAIRED AND 11.0 PI-311/PI-312 DURING OVERHAUL DAMAGED RECALIBRATED 850217 23 029187 JIC NATURAL WEAR / ISOLATION VALVE INSTALLED NEW VALVE 3.0 PT-83 AGE LEAKS AND PRESSURE TESTED 850128 27 029642 OPS BAD SAMPLE FLOW 101A READS REPLACED FLOW DIAPHRAGM 224 MAZ-101 REGULATOR DOWNSCALE

NE*J YORK POWER AUTHORITY - JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE SUPMARY FEBRUARY 1985 ACTION TAEEN REPAIR WORK REOUEST NO. Il0W CAUSE OF RESULTS OF 10 PRECLUDE TIME DATE SYSTEM CO"PONENT NO. DETECTED MALFITNCTION MALFUNCTION P Ert'RRENCE l!OURS 850214 71 023177 JIC PREVENTATIVE SETPOINT VERIF. WORKED THROUGH EXIDE 8.0 INV-3B MAINTENANCE ON LPCI U.P.S. PROCEDURE 850222 76 034526 OPS N/A TIMER NEEDS SET PERFORMED ST76J11- 1.0 SOV-106 FOR 145-155 SEC NO ADJ. NECESSARY 850211 93 034628 OPS SPEED SENSING EDG WOULD NOT CORRECTED SHORT 16.0 EDG "D" CKT MALFUNCTION SHUT OFF IN+65V BUS l

l

r.

IEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCEAR POWER FIAl?T SAFEIY REIATED ELECIRICAL & IECHANICAL !!AINITNANCE SlWARY FEBRUARY 1985 REPAIR WORK R$UEST / TIME DATE SYSTEM C W P0t E rr HOW DEIECTED CAUSE OF 1%1RJNCTION ACTION TAIGN 'IO PRECLUDE RECURRENCE HOURS 2/15/85 08 22525 OPS Misadjusted limit Adjusted limit switch; cleaned and 8 Refuel Bridge switch and corrosion. and lubricated th mb switch.

2/26 10 34647 LIRI Worn packing. Repacked. 22 MDV-27A 2/26 10 35505 LLRT Ucrn packing. Repacked. 63 MOV-25A 2/19 29 34504 OPS Water in position Replaced switch internals and 6 ADV-86B indication switch. gasket.

2/27 07 26385 OPS Faulty switch. Replaced switch. 8 7A-53E 2/15 24 34650 OPS Bent Door Linkage. Straightened linkage. 2 EOD-1 2/28 10 35413 LIRT Seat Irak. Disass abled ground seat and disc 166 MOV-31A -reassmbled.

3/2 08 34642 OPS Faulty solenoid. Replaced solenoid. 33 Pcfuel Bridge Monorail Hoist 2/1 01-125 34565 OPS Defective elapsed Replaced meter. 2 FN-1B time meter.

2/21 11 22661 N/A No malfunction. Performed F-ST-06 D & E 16 EV-14 A&B 2/11 24 34616 OPS Bent linkage. Straightened linkage. 32 EOD-1

- s

]

!! hBI YORK POWER AUI110RITY

, JAES A. FITZPATRICK NUCLEAR POWER PIXr SAFETY REIATED ELECIRICAL & MECHANICAL MAINIDMNCE SGNARY 4

1 lezAIR WORK REQUEST # TIME DAIE SYSIDI C WPONENT HOL7 Drau;1tu CAUSE OF MAIRRKT, ION ACTION TAKEN TO PRECLUDE RECUPJENCE HOURS i

2/6 24 34493 OPS Bent linkage. Straightened linkage. 10 EDD-2  :

1/30 27 34322 OPS Misadjusted limit Adjusted limit switch. 3 I VB-2 switch. t

. 2/7 46 34611 Breaker Faulty trip device. Checked cut motor and cabling. 76 j P-2A Tripped replaced trip device. ,

1/29 66 36274 N/A No tralfunction. Replaced unit cooler fan motors 6Je 278 to environmental qualification i

UC22A-K requirements.

J d

2/7 71 34626 OPS Dirt. Cleaned inverter and circuit 15 IIN-3B breakers replaced fuses.

2/20- 02 22623 N/A No malfunction. Disassenbled reactor vessel for 920 ,

j . VI refueling. ,

a 2/16 08 22659 Prevmtive Wear Adjusted brakes 18 Refuel Bridge - Maintenance Monorail i Hoist i

[

i l i

s-

r ,

+. 't J;me3 A. FitaPitrick Nucle:r Powre Plant PO. Ebu 41 Lycoming. New York 13093 315 342.3840 Harold A. Glovier

  1. b NewYorkPower

& Authority March 7, 1985 JAFP-85-0226 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION: DOCUMENT CONTROL DESK

REFERENCE:

DOCKET No. 50-333

Dear Sir:

Enclosed please find the J. A. FitzPatrick Operating Status Report for the month of February, 1985. Refueling information remains the same as previously submitted.

If there are any questions concerning this report, please contact John Cook at (315) 342-3 40, Ext. 439.

HAROLD A. GLOVIER IIAG:JPC:mac cc: Internal Distribution Enclosures Ilg '