I NUREG/CR-3132 l
UCRL-53047 Concentration and Distribution of Copper in Effluents from the H.B. Robinson Steam Electric Plant F. L. Harrison, D. J. Bishop, D. W. Rice, Jr., and J. P. Knezovich Prepared for U.S. Nuclear Regulatory Commission Lawrence Livem1 ore National Laboratory D
DO OO 61 P
pop
l l
l NOTICE This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nct any agency thereof, or any of their employees, niakes any warranty, expressed or implied, or assumes any legal liability of re-sponsibility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.
Availability of Reference Materials Cited in NRC Publications Most documents cited in NRC publications will be available from one of the following sources:
- 1. The NRC Public Document Room,1717 H Street, N.W.
Washington, DC 20555
- 2. The NRC/GPO Sales Program, U.S. Nuclear Regulatory Commission, Washington, DC 20555
- 3. The National Technical Information Service Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.
Referenced documents available for inspection and copying for a fee from the NRC Public Docu-ment Room include NRC corresoondence and ir,ternal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and corresponder ce; Commission papers; and applicant and licensee documents and correspondence.
The following documents in the NUREG serias are available for purchase from the NRC/GPO Sales Program: formal NRC staff and contractor reports NRC sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides NRC regulations in the Ccde of Federal Regulations, and Nuclear Regulatory Commission issuances.
Documents available from the National Technical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.
Documents available from public and special technical libraries nclude all open literature items, such as books, journal and periodical articles, and transactions. Federal Register notices, federal and state legislation. and congressional reports can usually be obtained from these libraries.
Documents such as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings are available for purchase from the organizatioriiponsoring the publication cited.
Single copies of NRC draft reports are available free upon written request to the Division of Tech-nical Information and Document Control, U S. Nuclear Regulatory Commission Washington, DC 20555.
Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are Americzn National Standards, from the American Nationil Standards institute.1430 Broadway, New York, NY 10018.
GPO Pnnted copy pnce $3x75
NUREG/CR-3132 UCRL-53047 RE 1
l Concentration and Distribution of Copper in Effluents from the H.B. Robinson Steam Electric Plant lla'r3Me1 M!N"8 gary 1983 Prepared by F. L. Harrison, D. J. Bishop, D. W. Rice, Jr., and J. P. Knezovich Lawrence Livermore National Laboratory 7000 East Avenue Livermore, CA 94550 Prepared for Division of Health, Siting and Waste Management Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, D.C. 20555 NRC FIN No. A-0119
ABSTRACT Water and bedload sediments were sampled at the intake and discharge areas of the H.B. Robinson Steam Electric Plant and at a. control area upstream of the plant in November 1979 and May and July 1980. Water samples were analyzed for total, for soluble and particulate, and for labile and bound copper; sediments were analyzed for total copper. During the July field survey, samples were taken at three additional sites downstream of the plant.
Total copper concentrations in water samples from the discharge area were always higher than in those from the intake.
Concentrations of copper in discharge waters ranged from 33 to 79 pg/L, whereas those in intake waters ranged from 27 to 58 pg/L. The concentration of copper in the water in the control area upstream from the power station ranged from 3.1 to 5.8 pg/L; this was significantly lower than that in the discharge and intake areas. Downstream water also contained less copper, with a low concentration of 12 pg/L and a high of 22 pg/L. The percent of copper in the particulate fraction was 20% in November, 30% in May, and about 40% in the July sampling period. In most samples, copper in the soluble fraction appeared equally as labile and bound. The concentration of dissolved organic carbon in the water samples from the impoundment area showed little variation with time; the values range from 3.8 to 5 7 mg C/L. The organic carbon in the particulate fraction was <1 mg C/L.
Determination of molecular size distribution of the copper and iron species by ultrafiltration of discharge and control waters indicated that the largest concentration of copper appeared in the > 10,000, < 100,000 molecular weight fraction both in untreated and UV-oxidized water. However, very little copper was found in the > l,000, < 10,000 fraction after UV exposure for 6 h.
The largest concentration of iron shifted from the > 10,000, < 100,000 fraction to the > 100,000 fraction following UV treatment.
Analysis of water for anions and 24 elements showed little change in concentration between intake and discharge waters of the same collection period. However, the control waters upstream were significantly lower in concentrations of copper, zinc, and calcium.
Copper concentrations in intact bedload sediments of the intake area ranged from 4.4 to 260 pg/g dry weight; those in the discharge area ranged from 6.1 to 72 pg/g.
Copper in the upstream sediments was very low, <3.7 pg/g. Higher concentrations appeared in the <62-pm fractions than in intact sediments. Copper distribution coefficients of intact bedload sediments in the intake and discharge areas ranged from 300 to 21,000, iii
CONTENTS iii Abstract List of Tables vi Preface vii Executive Summary 1
I Techniques 1
Findings Conclusions 2
Recommendations 2
Introduction 3
Site Characteristics 3
Materials and Methods 5
Sample Collection and Processing 5
5 Water and Suspended Particles Bedload Sediments 6
7 Reagents 8
Copper Analyses Water 8
Suspended Particles 9
Bedload Sediments 10 Apparent Complexing Capacity 10 Ultrafiltration 10 Organic Carbon Analyses 12 Distribution Coefficients 12 Suspended Particles 12 Bedload Sediments 13 Results and Discussion 13 Water Column 13 Soluble and Particulate Copper Concentrations 13 15 Copper Sorption Rates Copper Speciation 15 16 Apparent Complexing Capacity Copper in Molecular Weight Fractions 16 Bedload Sediments 22 Copper Concentrations 22 Distribution Coefficients 24 Particle Size Distribution, Carbon Content, and 24 Mineral Composition References 29 Appendix A. Procedure for Cleaning Sample Containers 33 Containers of < 10 pg Cu/L Samples 33 Containers of > 10 pg Cu/L Samples 33 v
LIST OF TABLES 1.
Analyses performed and volumes and numbers of samples collected from study sites at the H.B. Robinson Steam Electric Plant 6
2.
Temperature, pH, and conductivity of water collected at the H.B. Robinson Steam Electric Plant 7
3.
Copper concentrations (pg/L) in water collected at the H.B.
Robinson Steam Electric Plant 14 4.
Characteristics of suspended particles in water collected at the H.B. Robinson Steam Electric Plant 15 5.
Dissolved (DOC), particulate (POC), and total (TOC) organic carbon (mg C/L) in water collected at the H.B. Robinson Steam Electric Plant 17 6.
Percentages of 64Cu,59Fe, and dissolved organic carbon (DOC) in different molecular weight fractions of ultrafiltered water from the H.B.
Robinson Steam Electric Plant assuming unavailability of copper sorbed on walls and membranes 18 64Cu,59Fe, and dissolved organic carbon (DOC) 7.
Percentages of in different molecular weight fractions of ultrafiltered water from the H.B.
Robinson Steam Electric Plant assuming availability of all copper recovered 19 64Cu and 59Fe recovered in the dissolved 8.
Percentages of (filtrate plus the solution remaining in the ultrafiltration cell) and sorbed (to the walls and membrane) fractions of the ultrafiltered water 20 21 9.
Chemical species of copper 10.
Concentrations of soluble elements (pg/L) in water collected at the H.B. Robinson Steam Electric Plant 23 11.
Concentrations of anions (pg/L) in water collected near the H.B. Robinson Steam Electric Plant 24 12.
Copper concentrations in bedload sediments (pg/g dry weight) collected at the H.B. Robinson Steam Electric Plant 25 13.
Characteristics of sediments collected at the H.B. Robinson Steam Electric Plant 26 14.
Distribution coefficients for bedload sediments collected at the H.B. Robinson Steam Electric Plant 27 15.
Particle size distribution, organic carbon, calcium carbonate, and mineral content of intact bedload sediments collected from the H.B. Robinsm Steam Electric Plant, July 1980 28 vi
1 PREFACE This study is part of a larger research project that has three purposes: (1) to study the behavior of potentially toxic substances introduced to surface waters itam nuclear power stations; (2) to determine the magnitude of the impact of these substances on representative, economically important species; and (3) to develop models to predict the behavior and the impact of these substances. The initial thrust of the research was to investigate the impact of corrosion products from cooling systems, in particular, copper. Copper is of special interest because it is toxic to aquatic organisms.
We wish to thank the scientific staff of the Carolina Power and Light Company (CP&L) for their excellent cooperation and advice. Special thanks go to Dave Herlong from CP&L for his assistance in the collection of samples. The authors also thank Jack Dawson and Jacqueline Lam from Lawrence Livermore National Laboratory for their assistance in sample analysis.
vii
CONCENTRATION AND DISTRIBUTION OF COPPER IN EFFLUENTS FROM THE H.B. ROBINSON STEAM ELECTRIC PLANT EXECUTIVE
SUMMARY
Field studies were performed at the H.B. Robinson Steam Electric Plant to obtain a better understanding of the fate of copper corrosion products released from cooling systems to the impoundment. Data on copper are important for an assessment of its rate of dispersion in ecosystems, rates of interaction with other pollutants, final distribution, and toxic effects on biota.
Copper concentrations were obtained for the soluble and particulate fractions of water samples and in bedload sediments collected in control, discharge, and intake areas during November 1979 and May and July 1980; additional samples from the July 1980 collection period were obtained f-om three downstream locations and were analyzed for copper concentrations.
In addition, copper distribution coefficients (K s) of particles suspended in the water column and present in the d
bedload sediments were determined.
TECHNIQUES Several analytical techniques were used to identify the forms and quantities of copper present in the water. Total soluble and particulate copper were determined after separating the fractions by filtering the water through membranes with 0.4-pm pores. Labile copper in the soluble fraction was measured by an ion exchange technique and by differential pulse, anodic stripping voltammetry (DP ASV). Ultrafiltration indicated the molecular weight distribution of the copper and iron species and the effect of dissolved organic matter on distribution.
Suspended particles and bedload sediments were dissolved in acid and copper quantified by atomic absorption spectrophotometry. Copper K s were determined d
by radiolabeling techniques.
FINDINGS Total copper concentrations in water from the intake area ranged from 27 pg/L in July 1980 to 58 ug/L in November 1979; copper in the discharge water was also lowest in July at 33 pg/L and highest in November at 79 pg/L.
Copper concentrations in water from upstream (control) and downstream sites were always lower than those from intake and discharge areas within the impoundment. Control water had copper concentrations ranging from 3.1 to 5 8 ug/L, and downstream water ranged from 12 to 22 pg/L. Water from the July collection had the highest percettage of copper in the particulate fraction in comparison with the May and November collections. Labile and bound copper in the soluble fraction were approximately equal in most samples. The range of concentration of dissolved organic carbon in intake and discharge waters was small, from 3.8 to 5.7 mg C/L.
Determination of molecular size distribution of the copper and iron species by ultrafiltration of the soluble fraction of the discharge water from all three collection periods revealed the highest concentration of copper in the > 10,000,
< 100,000 molecular weight fraction (MWF). This same MWF had a high percentage i
of copper after UV oxidation for 6 h, although the percentage in the > 1,000,
< 10,000 MWF decreased significantly, if not entirely. Iron was also present in highest percentage in the > 10,000, < 100,000 MWF in untreated water, but >90% of l
the iron was found in the > 100,000 MWF following UV treatment. The percentages of copper in the various MWFs following UV oxidation of water from H.B Robinson aiffered somewhat from those of earlier studies in marine and estuarine waters, possibly because of the differences in salt content, but more likely because of the lower pH of H.B. Robinson water.
Intact bedload sediments from the discharge area contained copper ranging from 6.1 to 72 pg/g dry weight; copper in sediments from the intake areas ranged from 4.4 to 260 pg/g. Higher concentrations appeared in the <62-um fraction than in Copper K s of intact bedload sediments from discharge and intact sediments.
d intake areas ranged from a low of 300 in November 1979 to a high of 21,000 in May 1980.
CONCLUSIONS Total copper concentrations in influent and effluent waters collected at H.B. Robinson were in the range reported to be toxic to sensitive organisms such as some species of primary producers and early life stages of some species of higher trophic-level organisms. Because a high percentage of copper in water from both intake and discharge areas was in the labile form (33 to 45%), biota in the impoundment should be monitored on a regular basis for possible adverse effects.
Downstream water analyses showed that the copper was diluted, so the impact of such effluents would be limited to the impoundment area.
Ultrafiltration of H.B. Robinson water into MWFs demonstrated the presence of copper predominantly in the intermediate MWFs from >1,000 to <100,000 and iron predominantly in the > 10,000, < 100,000 MWFs. In water that was UV oxidized, a low percentage of copper was present in the >1,000, <10,000 MWF and of iron in the > 10,000, < 100,000 MWF. These data indicate that the two metals behave differently in the presence and absence of organic ligands.
The concentration of copper in the bedload sediments from both intake and discharge areas showed significant increases in May and July 1980 compared with November 1979. This increase in copper may indicate a buildup of copper in the sediment with time.
RECOMMENDATIONS The physicochemical forms of copper in the H.B. Robinson water appear to be different from those at other freshwater sites. Additional data are needed to establish whether the copper partitioning and binding behavior was attributable to the lower pH of the water system and/or to differences in the kinds and quantities of organic ligands present.
The partitioning between the soluble and particulate forms of copper as well as the nature of the physicochemical forms may affect its availability to the biota.
Therefore,it is important to further study the effects of environmental factors and seasonal variations on the speciation, sedimentation, and bioavailability of copper in the ecosystem.
2
INTRODUCTION The siting of nuclear power stations adjacent to freshwater ecosystems has been a common practice because of the need for cooling water. However, the use of these waters has not only added waste heat to the ecosystem, but also corrosion products from the heat exchangers. The impact on local ecosystems from power station waste waters is dependent on the quantities of corrosion products released and their physical and chemical forms (Ref.1).
Copper alloys are frequently used in cooling systems because of their favorable heat exchange and antifouling properties. Previous investigations of the effect and distribution of copper corrosion products in effluents from power stations have been conducted (Refs. 2-7). Copper corrosion products were implicated in the abalone kill that occurred in the discharge cove of the Pacific Gas and Electric Company, Diablo Canyon Nuclear Power Station before the copper-nickel tubing in the cooling system was replaced by titanium tubing (Ref. 8). However, our investigations of the concentration arid physicochemical forms of copper in the intake and discharge areas of the Diablo Canyon and San Onofre Nuclear Power Stations in California and of the Surry and Salem stations in the East indicate that we can expect little or no impact from the release of copper when the stations are operating normally and no chemicals are added to the cooling water (Refs. 4-6).
The present investigation was initiated to determine the impact of the use of copper alloys in cooling systems of nuclear power stations situated on cooling lakes. The H.B. Robinson Steam Electric Plant was selected for study because there is some recirculation of the discharge waters, and the station has a long history of operation.
SITE CHARACTERISTICS The H.B. Robinson Steam Electric Plant is located near Florence, South Carolina, and is operated by the Carolina Power and Light Company (CP&L). The power station consists of two units. Unit I has a gross capacity of 185 MW and is coal fired. Unit 2 has a gross capacity of 700 MW and is nuclear. Condensers of both units are cooled with water drawn from and returned to the H.B. Robinson impoundment. When the field survey was conducted, the tubing in the condensers of both Units I and 2 was constructed of 70-30 copper-zinc alloy. During March 1982, the old tubing was removed and replaced with stainless steel tubing.
The Robinson impoundment is on Black Creek, a tributary of the Pee Dee River (Fig.1). Black Creek is a typical blackwater stream exhibiting a combination of low pH (3.9 to 6.7) and darkly colored water that results from the leaching of organic material from the swampy headw 1ter drainage.
Sample collections were made in November 1979 and in May and July 1980.
Samples were collected from two sites each in the intake zone, the discharge zone, and a control site upstream of the plant. During the July 1980 collection, three additional sites (referred to here as I, II, and 111) downstream of the impound nent t
were also sampled. The power station was operating normally during all col!ections.
3
l Control site 1
Black Creek N
3 b
Discharge Scale in miles 0
1/. 2 1
2 t
-j D
o
\\/
Units 1 & 2 J bm o U Dam Intake Figure 1. Location of Units I and 2 of the H.B. Robinson Steam Electric Plant near Florence, South Carolina.
4
MATERIALS AND METHODS SAMPLE COLLECTION AND PROCESSING Water and Suspended Particles During all samplings at the H.B. Robinson Steam Electric Plant, we used the following water and suspended-particle collection procedures. Filtered water was collected through an all-plastic peristaltic pump at about 50 mL/ min. The water sample intake was covered with a 150mm (pore size) nylon screen. Water samples were filtered in situ through a 0.4-um (pore size), Nuclepore 293-mm (diam) membrane filter and collected into meticulously cleaned (ultraclean) polypropylene 8-L carboys (see Appendix A). A separate filter was used for filtering the water collected in each carboy. Filtration was stopped when the flow from the filter was
<10 mL/ min. The filter carrier was then purged of water and the filter removed and placed in an ultraclean vial. The volume of water that passed through each filter was recorded. A 1-L aliquot of filtered water was removed at the collection site from each carboy and acidified to pH 1 with hcl to reduce sorption of copper to the walls of the container.
Unfiltered water samples were collected in two ways. Water samples used to determine the copper distribution coefficients (K s) of suspended particles were d
pumped directly into ultraclean 1-L bottles. Unfiltered water samples for the analysis of organic carbon were collected in precombusted (450*C), 1-L glass-stoppered bottles by submersing them to a depth of about 0.5 m until they were filled. Triplicate 10-mL aliquots of the water were placed in precombusted glass vials for analysis of total organic carbon (TOC). From the remainder of this unfiltered water sample, two aliquots of different sizes were then filtered in triplicate through precombusted glass-fiber filters. Each loaded filter was placed into a precombusted glass vial and sealed with aluminum foil for subsequent particulate organic carbon (POC) analysis. Aliquots of the pooled filtrate were also placed into precombusted vials for subsequent dissolved organic carbon (DOC) analysis. The TOC, DOC, and POC samples were frozen as soon as possible. The analyses performed and the kind, number, and volume of samples collected from the water column at the study sites are summarized in Table 1.
Because of the difficulty of establishing differences among stations when copper concentrations are only a few micrograms per liter, extrerne care was taken to keep the equipment free from contamination.
Before use, the plastic water-sampling pickup tubing, the peristaltic pump chambers, and the polyvinylchloride filter carrier were acid washed and rinsed with doubly (glass-)
distilled water (DDW). The containers used to transport and collect samples were cleaned carefully (see Appendix A) and transported in plastic bags. After collection, all samples were immediately sealed in the field, enclosed in plastic bags, and shipped in crushed ice to the Lawrence Livermore National Laboratory (LLNL). Samples were received at LLNL 12 to 24 h af ter collection.
Intake water samples were collected 3 to 4 m offshore near the entrance to the cooling system; discharge water from near the mouth of the discharge canal; and control water from Black Creek, upstream of the plant (Fig.1). The water was sampled 30 to 60 cm below the surface during collections at all three sites. The temperattre, pH, and conductivity of the water were measured (Table 2).
Table 1. Analyses performed and volumes and numbers of samples collected from study sites at the H.B. Robinson Steam Electric Plant.
Volume of replicate Replicates Analysis (L)
Intake Discharge Filtered water Total copper (acidified) 1 4
4 Labile copper 8
3 3
Ultrafiltration 8
2 2
Dissolved organic carbon 0.01 3
3 Dissolved organic carbon 0.005 3
3 Unfiltered water Total organic carbon 0.01 3
3 Copper distribution coefficient 1
3 15 Nuclepore filters Weight of suspended particles 4
4 Copper concentration of suspended particles 4
4 Glass-fiber filters 6
6 Particulate organic carbon J
Bedload Sediments During all field surveys, we collected bedload sediments from intake and discharge areas and from the control area. In each sampling area, collections were made at each of two or three sites. A stainless-steel ponar dredge or plastic coring device was used to remove approximately I kg of sediment from the top 6 to 10 cm of the bedicad. The samples were immediately placed into plastic bags, purged of any air, and tightly sealed. All samples were held at ambient temperature, and th and pH were measured within 4 to 6 h of collection in a glove bag filled with nitrogen.
The dredged sediment samples were homogenized by kneading, a small incision was made in the bag, and the Eh and pH measurements were made. For all collections, one aliquot of sediment homogenized by kneading in a plastic bag was treated as an intact sample; a second aliquot was filtered through a 62-um (pore size) Nitex screen to separate the fine-grain component. The < 62-um sediment fraction was washed through the screen using filtered water from the collection site.
6
Table 2.
Temperature, pH, and conductivity of water collected at the H.B.
Robinson Steam Electric Plant.
Collection Collection Temperature Conductivity date site
('C) pH (p0 cm-I)
November 1979 Intake 20.6 5.6 Discharge 30 5.7 Control 4.7 May 1980 Intake 25.5 5.5 60 Discharge 33 5.4 70 Control 23 5.2 July 1980 Intake 32 5.7 40 Discharge 40 5.6 40 Control 24.5 5.3 25 Downstream I
33 5.3 39 11 32 4.8 60 111 33 6.7 160 The <62mm sediment fractions in wash water and intact sediment were held at 4*C and shipped to LLNL. On arrival, the samples of <62-um sediment fractions in wash water were centrifuged at 90,000 x g for 20 min. The wash water was decanted from the sediment, and the fine sediments were mixed well with a porcelain spatula before analysis. Intact sediment samples collected for sediment characterization were dried at 100*C for 48 h.
Samples.were stored in glass containers until they were shipped to Dr. D. S. Gorsline at the University of Southern California for analysis of particle size distribution and of total carbon and CACO 3 content. Particle size was determined using a settling tube apparatus.
Orgame material in the sediment was determined on a Leco Carbon Analyzer in which total carbon and CACO 3 are measured and the organic carbon constituent is then calculated by the difference.
Mineral composition was determined by x-ray diffraction by Dr. Alan Colville at California State University at Los Angeles.
REAGENTS J. T. Baker Ultrex-grada nitric, perchloric, and hydrochloric acids were used throughout, except as indicated. The DDW water was passed through a column of Chelex-100 resin before it was used as a solvent for all reagents and standards. All reagents were of analytical grade or higher purity. Polypropylene and Teflon labware was used.
7
1 COPPER ANALYSES l
Water Total soluble copper was determined by direct injection of a filtered, acidified water sample into a model HGA 2100 graphite furnace attached to a model 303 Perkin Elmer Atomic Absorption Spectrophotometer (AAS) and by differential pulse, anodic stripping voltammetry (DP ASV)(Ref. 9). On the AAS, sample copper concentrations were determined by the method of additions. Four 40-mL aliquots were spiked with copper to yield copper concentrations of 0.002, 0.004, 0.006, and 0.008 pg Cu/mL in addition to the original copper concentration in the sample; one 40-mL aliquot received no copper spike. The sample injection volume was 50 UL.
A least-squares linear regression analysis was performed on the resulting data. The total copper originally present in the sample was obtained by dividing the y-intercept value by the slope of the regression line.
With DP ASV, copper is reduced at a potential more positive than the reduction potential (vs Ag/AgCl reference cell) and concentrated onto a mercury electrode.
The amalgamated copper is measured by anodically stripping the copper from the mercury electrode by applying a potential gradient and measuring the current produced as the system reaches the oxidation potential of copper. The anodic stripping current i is proportional to the equilibrium concentration of the kinetically labile metal, i = kc (Mn+), where k is an empirical constant whose c
value depends on the electrode geometry and surface area; cell geometry; stirring efficiency in the cell; length of preelectrolysis; scan rate of the linear stripping potential; and diffusion coefficient of copper, both in solution and in mercury (Ref.10). A Princeton Applied Research 374 polarographic analyzer with a Hewlett-Packard microprocessor and X-Y recorder was used. The electrode system consisted of an Ag/AgCl reference electrode, a platinum counter electrode, and a hanging mercury-drop working electrode. Preporified N2 was used to purge samples of dissolved oxygen. All measurements were made at room temperature (20 2*C). Analyses were performed in Teflon cups that had been washed with nitric acid and rinsed with purified water.
Labile copper was measured using Chelex-100 ton-exchange resin and by polarographic analysis. The Riley and Taylor mett'od was used to determine the amount of copper bound to the Chelex-100 ion-exchange resin (Ref.11). The filtered water samples were processed immediately upon arrival at LLNL. No alteration was made in the pH of the water. Each 8-L carboy was fitted with tubing to permit the water to be gravity fed into a 2-cm-diam borosilicate glass column packed with 5 cm of Chelex-100 resin in the ammonium form (Fig. 2). The rate of flow of water through the column did not exceed 5 mL/ min; flow rate was adjusted by altering the height of the water sample carboy. After the water sample passed through the column, the column was eluted with two 10-mL aliquots of 2N_ HNO3 to collect the species of copper bound to the resin. Af ter use, the filtered-water sample carboys were rinsed thoroughly with 50 mL of 2N HNOy.
This acid rinse removed copper adsorbed on the carboy walls. Copper recovered in the acid rinses was considered to be part of the labile component.
Eluants from the columns and the acid rinses of the carboys were analyzed by direct aspiration into the flame of the AAS or by direct injection into a graphite furnace attachment to the AAS. All standards were prepared in 2N_ HNO.
3 8
M
Sample water carboy Column effluent carboy Chelex-100 column
(
/w' A
\\
10 O I T
Lab jack O
f
/
\\
.w s
n o o,
Figure 2.
Gravity-fed system used to pass filtered water sample through Chelex-100 resin.
Because the levels of copper in the water were low, special care was taken in the preparation of the Chelex-100 resin and the columns (Ref. 4). The resin was washed carefully, converted to the ammonium form, and packed into a column in a laminar-flow clean hood using talc-free gloves. Average copper values for the Chelex-100 column blanks were subtracted from those of the samples.
Copper ig the column blanks was low; the eluant contained 2.8 1 0.6 x 10 pg Cu/mL. This was usually < 2% of the total copper in the sample eluant.
Labile copper concentrations were determined also by DP ASV. Either 5 or 10 mL of water were added to a cup and then the sample was purged with N2 or 10 min, f
deposited for 6 min at -0.6 V, and then scanned from -0.6 to 0 V or 0.1 V at 10 mV/s. A medium mercury-drop size was used, and the sensitivity was I p A full scale. Supporting electrolyte for the analyses was provided by the addition of 100 pl of IM NaC10. Subsequent to the analysis for labile copper, each sample 4
was acidified with 50 to 150 pL of perchloric acid to dissociate the copper ligands, digested for up to 2 wk, and then analyzed for total copper.
Suspended Particles The wet and dry weights of particulate material collected on the Nuclepore filters was determined and analyzed for copper. The filters were placed in clean platinum crucibles for drying, ashing, and digesting. The filters were dried at 100*C for 9
l l
48 h; then the dry weights were recorded. The filters were then placed in a muffle furnace, the temperature was raised from 100 to 450*C at 50*C/h, and the samples were ashed for 48 h at 450*C.
Each filter was digested with 10 mL of analytic-grade, concentrated hcl and 10 mL of analytic-grade HF. After the samples were evaporated to dryness at about 200*C,10 mL of analytic-grade HNO3 were added and the samples again evaporated to dryness. The samples were then dissolved in 2N HNO, transferred to 25-mL volumetric flasks, brought to 3
volume, and analyzed on the AAS. Ccpper concentrations were corrected for the amount of copper in filters and reagent blanks. Filters plus reagent blanks averaged 3.2 pg copper per digestion. This was usually less than 0.5% of the total copper recovered from the suspended particles on the filter. Suspended particulate dry weights were also corrected for filter-blank dry weights. Because it was noted that filter dry-weight blanks vary with different filter lots, care was taken to keep track of the lots used.
Bedload Sediments Total copper in the intact sediments and < 62-um sediment fractions was determined after acid digestion. Sediments were dried at 100*C for 48 h and then powdered using a porcelain mortar and pestle. Triplicate aliquots of sediment samples of about 0.25 g were weighed in platinum crucibles and ashed at 450*C for 48 h. Total copper in the sediments was determined by the same acid-digestion procedure described for the suspended particles. Copper concentrations in the sediments were corrected for the amount of copper in the reagent blanks. The blanks averaged 0.3 0.1 pg copper per digestion. This was usually less than 2% of the total copper recovered in sediments. Our procedures were verified by analyzing National Bureau of Standards (NBS) orchard leaves on three separate occasions. Our analyses averaged 12.2 1 pg Cu/g dry weight. The NBS analysis yielded 12 1 pg Cu/g dry weight.
APPARENT COMPLEXING CAPACITY The apparent complexing capacity (ACC) was determined using the polarographic method of Chau et al. (Ref.12). Either 5-or 10-mL samples of filtered water were aliquoted into cups and then spiked with quantities of copper that would result in concentrations of added copper ranging from 1 to 100 pg/L. The spiked samples were equilibrated 15 to 18 h at 10*C; then a labile copper analysis was performed on each sample. The area of the copper peak on each voltammogram 2
was determined and plotted on the Y-axis versus concentration of added Cu +. The complexing capacity of the sample corresponds to the copper concentration intercepted on the abscissa.
ULTRAFILTRATION Two 2-L aliquots of filtered water that had been stored at 4*C since collection (24 64 to 48 h) were spiked with Cu, allowed to equilibrate a minimum of 12 h, and ghen 6 Cu subjected to ultrafiltration (Fig. 3). After the 12-h equilibrium period, the serves as an effective tracer for the different species of stable copper present in the water at the time of analysis.
One of the 2-L aliquots was photooxidized with UV light to reduce the concentration of dissolved organic matter. The UV treatment destroys most effectively those molecules that strongly absorb UV irradiation. Two drops of 35%
10
Ultrafiltration method Water (pH 7.8) v Water + radionuclide (12 to 18 h) o Separation (Amicon membranes) e v
Radionuclide analysis Radionuclide analysis of filtrate of retained solution Figure 3. Ultrafiltration procedure flow diagram.
HO2 were added to each 100 mL of water to accelerate the oxidation. The 2
reaction rate was also increased by the higher temperature that occurs during irradiation (60*C).
Care was taken in the UV irradiation step to avoid contaminating the samples. The quartz irradiation tubes were rinsed with 0.lN hcl and then with DDW before use. To determine the loss of qopper to the walls 7 aliquots taken before and after irradiation were counted for 64Cu; in all samples, the 64Cu concentrations were lower af ter irradiation.
Ultrafiltration was performed with standard model 402 cells, which contained magnetic stirrers (Amicon Corporation, Lexington, MA). Membranes used for the experiment were the XM-100A, UM-10, and UM-2 types (Amicon Corporation Diaflo). These membranes are made of complex, noncellulosic hydrous gels of inert polymers, which allow for retention of molecules above a specified molecular weight. The nominal molecular weight retentions of the membranes used in this test are as follows: XM-100A,100,000; UM-10,10,000; and UM-2,1,000. The retention is related to the shape, as well as the size, of the molecules. For elongated molecules, the molecular weight cutoff is larger than the nominal one.
Some teaching of organic matter, resulting mostly from the glycerin protective coating applied by the manufacturer, occurs when these membranes are first used.
All membranes were pretreated to reduce organic material and metal contamination. Under positive N2 pressure, 50 mL of 0.lN_ hcl and 2 L of DDW were passed through the membranes sequentially. This procedure was adopted 11
af ter monitoring the filtrates on a spectrophotometer at 200 nm and analyzing the filtrate for soluble organic carbon; the treatment resulted in adequate reduction of potentially interfering substances.
Each ultrafiltration experiment was initiated by transferring 270 mL of the 64Cu-spiked water to an ultrafiltration cell. The water was stirred for 3 min, three 10-mL aliquots were removed for counting, the remaining 240 mL was subjected to positive N2 Pressure and constant stirring until 120 mL of filtrate was collected, and then the cell was vented. The filtrate was sampled serially to 64 monitor the changes in Cu concentration; a 10-mL sample was taken from each of the first, second, and third 40-mL aliquots of the filtrate. The retentate was sampled only after venting. The filters were removed and placed in vials for counting. The cell assembly was rinsed well with 50 mL of 0.lN hcl, and a 10-mL 64Cu p7esent in the initial aliquot of this acid wash was counted. Recovery of the 64 test solution was calculated from the Cu concentrations in the different fractions.
ORGANIC CARBON ANALYSES Analyses for organic carbon were performed on unfiltered water samples as well as the soluble and particulate fractions of water that had been filtered through precombusted glass equipment. The filter and filtrate were analyzed for POC and DOC, respectively, with an Oceanography International Carbon Analyzer by the standard persulfate oxidation method (Ref.13). Unfiltered water was analyzed for TOC.
DISTRIBUTION COEFFICIENTS Suspended Particles Copper K s of particles in the unfiltered water were determined. Each 1-L bottle d
containing water was spiked with 64Cu within a few hours of arrival at LLNL. The bottles were placed in a water bath at 12 to 14*C and shaken continuously before filtration. The times between the addition of the 64Cu spike and filtration were generally 0, 0.25, 0.5, 0.75,1, 4, 8,12,16, and 24 h.
The entire sample of water was filtered thrcugh a 0.45-ym (pore size) Millipore filter. Af ter filtration, the bottle and the filtration apparatus were rinsed with 25 mL of 0.lN hcl to remove sorbed 64Cu. Activities of 64Cu were determined in the unfiltered water, in duplicate samples of the filtrate, in the material on the filter, and in the acid wash.
Recovery of the added radionuclide was generally >95%.
In preliminary experiments, the sample of water was filtered through two 64 membranes. The first membrane contained activity from Cu on particles and 64Cu sorbed on the membrane; the second membrane contained only sorbed 6tu.
The difference between the two represents the activity associated with the particles. The quantities sorbed were extremely small compared with those associated with the particles. The use of two filters was therefore discontinued in 64 later samples, and no correction was made for Cu sorbed by the membrane. All samples were counted in a gamma well counter and corrected for background counts and decay to the zero time of the experiment.
12
l I
The K s were calculated from the data and the following relationship:
d Kd * (1 - fs)
- where is = fraction of Cu on filter, N
(1 -is) = fraction of Cu in filtrate, V = weight of water (g), and W = dry weight of particles (g).
64 The Kd as defined is dimensionless, and greater sorption of Cu to the particulate fraction results in higher K s.
d Bedload Sediments The K s of bedload sediments were determined by weighing about 0.75 g of d
sediment directly into acid-washed, 6-oz polyethylene bottles and adding 100 mL of filtered water that was spiked with tracer quantities of 64Cu. The bottles were placed in a water bath at 12 to 14*C and shaken continuously for approximately 24 h.
The samples were processed by procedures similar to those used for suspended particle samples. Duplicate samples were analyzed.
RESULTS AND DISCUSSION WATER COLUMN Soluble and Particulate Copper Concentrations Total copper concentrations in the discharge waters differed greatly during the three sampling periods; the range was 32.6 to 79.3 pg Cu/L (Table 3). The highest concentration we observed was in November 1979. However, the maximum concentration that was present in discharge waters and the total range that occurred may have been considerably greater than we observed. In the routine analysis of discharge waters conducted by CP&L, total copper concentrations of
>l 50 pg/L were documented approximately 15 times during 1981 (Ref.14).
Concentrations in the intake and discharge waters were about an order of magnitude higher than in those from the control site. The differences between intake and discharge waters were not constant and the largest was detected in November 1979. Samples collected downstream from the power station were lower than those from the intake and discharge zones but higher than those from the control area. The first downstream site was at the second bridge below the H.B.
Robinson Dam, the second at the Prestwood Dam, and the third about 2 mi below the Prestwood Dam.
The partitioning of copper between the soluble and particulate fractions of the water was highly variable. The particulate fraction was about 20% of the total copper in water collected from both the intake and discharge sites in November 1979, about 30% in that collected in May 1980, and about 40% in that collected in 13
1 Table 3.
Copper concentrations (pg/L) in water collected at the H.B. Robinson Steam Electric Plant.
Fraction Collection Collection Sc!uble date site Total Particulate Labited Bound Total Nov.1979 Intake 57.8 11.5 26.4 19.9 46.3 Discharge 79.3 18.6 33.9 26.8 60.7 Control 3.1 0.5 1.5 1.1 2.6 May 1980 Intake 33.9 10.4 12.3 11.2 23.5 Discharge 48.1 12.8 18 17.3 35.3 Control 3.8 0.7 0.3 4.8 5.1 July 1980 Intake 27.4 11.5 9.1 6.8 15.9 Discharge 32.6 14.7 13 4.9 17.9 Control 3.1 0.3 0.6 2.2 2.8 Downstream 1
22.4 8.3 14.1 11 11.7 4.6 7.1 Ill 16.8 9.7 7.1 a Chelex-100-tabile copper.
July 1980. The control water had low percentages of particles; values ranged from 10 to 16L Except in downstream sample 111 collected in July 1980, the percentage of copper was larger in the soluble than in the particulate fraction of the water; the range was from 55 to 88 Characterization of suspended particles in the water column showed that the variations in copper concentrations in the particulate fraction resulted from differences both in the quantities of the particles and in the amount of copper associated with the particles (Table 4). Large differences were also observed in K s and POC.
d Total copper concentrations in freshwater has been determined for a number of sites (Ref.15). Concentrations of copper observed in samples of discharge water from the H.B. Robinson site were higher than most of those from other power stations. The higher concentrations may be attributable to the low pH of the water. High total concentrations were reported also in drainage from a copper mine near Lake George in Uganda (Ref.16). However, in this body of water the pH ranged between 8 and 10.
Large variations in partitioning of copper between soluble and particulate fractions have also been determined at other sites (Ref.15). Differences may result from the primary physicochemical form of the copper discharged, from reactions occurring under the variable conditions that are present in the environment, or from changes in hydrology and sedimentation. Important environmental variables 14
Table 4.
Characteristics of suspended particles in water collected at the H.B.
Robinson Steam Electric Plant.
Suspended Collection Collection Copper particles POCa date site Kd (pg/g dry)
(mg/L)
(mg/L)
Nov.1979 Intake 29,300 2,700 4.1 0.5 Discharge 19,400 2,600 6.7 0.6 Control 15,900 131 4.8 0.2 May 1980 Intake 2,300 1,300 81 0.9 Discharge 4,400 1,500 8.9 1.1 Control 3,700 50 15.8 0.4 July 1980 Intake 37,200 1,300 9.5 0.9 Discharge 25,400 1,280 11.7 0.8 Control 10,200 15 17.1 0.7 Downstream I
8,000 549 15.1 1.4 11 20,200 375 12.4 0.5 III 16,100 310 31.1 3.2 a particulate organic carbon.
include salinity, pH, Eh, and concentrations of other metals; important processes include coagulation, coprecipitation, and sorption.
Copper Sorption Rates The rate of sorption of radiolabeled copper with the particulate phase of unfiltered water c llected from the discharge area was generally rapid; equilibrium occurred within the first 15 min after the 64Cu was added.
Copper Speciation The distribution of copper between labile and bound forms in the soluble fraction of water collected at H.B. Robinson differed greatly (Table 3).
At the three collection sites, both the absolute amounts in the labile and bound fractions and the percentages differed with sampling time. The percentages of labile copper in the soluble fraction of the intake water samples were similar, averaging about 55%.
The percentages of labile copper in discharge water samples ranged from 51 to 73%. The highest percentage was observed in July and may possibly have been due to the high water temperature in the impoundment during the summer months (Ref.17).
Labile copper concentrations determined using Chelex 100 differed from those determined by DP ASV. The two methods are reported to quantify different species of labile copper (Ref.18). The Chelex-100 labila copper is the fraction 15
that binds to Chelex-100 ion exchange resin at pH 7.8, and the DP ASV labile copper is the fraction that is available for deposit onto, and stripping from, a hanging mercury-drop electrode at pH 7.8. We had some difficulty in determining labile copper by DP ASV. We attributed this to poisonlig of the electrode by the high concentrations of dissolved organic material that was present in the waters.
(
This organic material was quite refractory; we found that it was necessary to digest the DP ASV samples at pH I for as long as two weeks to obtain total soluble copper values that agreed with those determined by AAS.
Apparent Complexing Capacity All samples of the intake and discharge waters analyzed by DP ASV showed DP ASV-labile copper. This indicates that there were insufficient ligands in the appropriate chemical form to bind all the copper. An indication of the variation in the availability of copper-binding ligands can be obtained by comparing the quantities of bound copper in the water samples. Values of bound copper in the discharge waters were not the same as those in the intake waters; the values from both sites ranged from 4.9 to 27 pg Cu/L.
Concentrations of organic carbon in the waters from the three collection sites were determined (Table 5). Concentrations of DOC ranged between 3.8 and 6.4 mg C/L and showed no relatio.. ship with bound copper (compare Table 3 and 5). However, some correlation is apparent between DOC concentration and total copper in water samples from the three sites.
The measurement of complexing capacity of waters has been reviewed recently
( Ref.19).
The methods used to determine complexing capacity include solubilization (Refs. 20-24), biological response (Refs. 25-27), voltammetry (Refs. 4, 5,18, 21, 28-37), ion exchange (Ref. 38), and selective ion electrodes (Refs. 39, 40). The values obtained for complexing capacity range from 32,000 pg Cu/L for an oil field brine (Ref. 20) to 1 pg Cu/L for pristine waters off the coast of California (Ref. 4). In general, the complexing capacities of marine waters are lower than those for estuaries and freshwater ecosystems.
High and variable values for ACC were determined for both estuarine water and freshwaters (Refs. 5,15). These contrast with the low values observed at Diablo Canyon and San Onofre Nuclear Power Stations. However, it is expected that higher concentrations of humic and fulvic acids would be present in freshwater and estuarine water than in marine water because of the runoff from the land and the high productivity of many freshwater and estuarine ecosystems.
Copper in Molecular Weight Fractions In the filtered water samples collected from the discharge zone of the power station, the percentage of copper in each of four MWFs (<1,000; >1,000, <10,000;
> 10,000, < 100,000; and > 100,000) differed with time and site. Because of the uncertain availability of ultrafiltration for the 64Cu-tagged copper that was sorbed on the walls and membrane of the ultrafiltration chamber, the percentage in each MWF was calculated in two ways: (1) by assuming that the available 64 Cu-tagged copper was only that in the filtrate and in the solution remaining in the chamber (retentate), and (2) by assuming that the available copper was that which was recovered from all parts of the ultrafiltration system. Table 6 shows the results from the ultrafiltration of the water samples, assuming unavailability of copper sorbed on the walls and membrane. In contrast, Table 7 shows the results based on 16
l Table 5.
Dissolved (DOC), particulate (POC), and total (TOC) organic carbon (mg C/L)in water collected at the H.B. Robinson Steam Electric Plant.
Collection Collection date site DOC POC TOC Nov.1979 Intake 4.9 0.5 5.4 Discharge 4.9 0.6 5.5 Control 6.4 0.2 6.6 May 1980 Intake 5.7 0.9 6.6 Discharge 4.6 1.1 5.6 Control 6.2 0.4 6.6 July 1980 Intake 4.2 0.9 5.1 Discharge 3.8 0.8 4.6 Control 4.9 0.7 5.6 Downstream I
2.7 1.4 4.1 11 3.3 0.5 3.8 Ill 8.6 3.2 11.8 the assumption of availability of all the copper recovered. A comparison of the data in Tables 6 and 7 shows that the agreement is better for the untreated than for the UV-treated water. This is expected because more copper is sorbed af ter the organic matter is destroyed by UV treatment (Table 8).
64Cu-tagged copper in the untreated samples was in the The largest fraction of
> 10,000, < 100,000 MWF. In waters treated with UV light for 6 h, the percentage of the copper increased in the < 1,000 and > 10,000, < 100,000 MWFs and decreased in the > l,000, < 10,9000 and > 100,000 MWFs. In May and July 1980, the samples 5 Fe as well as 64Cu. The distribution of the 59Fe before and were spiked with after treatment with UV differed from that of the 64Cu. However, more than 48%
of both 64Cu and 59Fe was present in the > 10,000,59< 100,000 fraction in all of the For Fe, almost all activity was non-UV-treated waters that were collected.
associated with the > 100,000 MWF after UV treatment.
The DOC in the untreated waters was not present in the four MWFs in the same percentages as that of copper and iron and differed greatly with sampling time.
The sample collected from the discharge area in July had a much larger percentage of DOC in the <1000 MWF. Analysis for DOC af ter UV treatment indicated that most of the DOC was not destroyed. Similar results were observed in water collected from the Surry Nuclear Power Station in October 1978 (Ref. 5). These data indicate the presence of small organic molecules that do not absorb UV light and consequently are not degraded by the 6-h exposure.
64 Recovery of Cu added to the water samples initially ranged between 95 and 104%; the mean is 99 4 in the untreated water and 94 5 for the UV-treated water. The final distribution of the 64Cu spike added to each water sample 17
64Cu, 59Fe, and dissolved organic carbon (DOC) in Table 6.
Percentages of different molecular weight fractions of ultrafiltered water from the H.B. Robinson Steam Electric Plant assuming unavailability of copper sorbed on walls and membranes.
Collection UV Molecular weight fraction date and treatment
<1,000
>1,000,
> 10,000,
> 100,000 location Analysis (h)
< 10,000
< 100,000 Nov.1979 64Cu 0
12 15 65 8
(Discharge) 6 24 2
70 4
DOC 0
0 29 53 18 6
0 0
0 0
64Cu 0
12 26 48 14 May 1980 (Discharge) 6 22 1
69 8
59Fe 0
4 6
64 26 6
2 0
2 96 DOC 0
15 2
19 64 6
0 0
0 0
64Cu 0
13 24 51 12 July 1980 (Discharge) 6 41 0
59 0
59Fe 0
1 3
54 42 6
1 0
0 99 DOC 0
43 21 9
27 6
97 3
0 0
64Cu 0
10 12 69 9
July 1980 (Control) 6 20 6
74 0
59Fe 0
2 2
55 41 6
1 0
3 96 64Cu in the differed with the water and treatment (Table 8). The percent of the dissolved fraction (filtrate and retentate) of untreated water for all samging periods was 93 4, and that of UV-treated water was 92 1 8. The amount of Cu in tne dissolved and sorbed fractions underwent little change after UV treatment.
The pH of all H.B. Robinson water samples used in ultrafiltration ranged between 5 and 6.2. A negligible pH change of <0.1 pH units occurred after UV oxidatiog4for 6 h, unlike observations by Laxen and Harrison (Ref. 41). The percent of Cu sorbed onto the filters was 3.5 for untreated water and 2.9 for UV-treated water.
The acid wash of the walls recovered 3.2% 64Cu in untreated water and 4.7% in UV-treated water. The 59Fe behaved more typically like Cu from previous 64 18
64Cu, 59Fe, and dissolved organic carbon (DOC) in Table 7.
Percentages of different molecular weight fractions of ultrafiltered water from the H.B. Robinson Steam Electric Plant assuming availability of all copper recovered.
Collection UV Molecular weight fraction date and Analysis treatment
<1,000
>1,000,
> 10,000,
> 100,000 location (h)
< 10,000
< 100,000 Nov.1979 64Cu 0
11 14 61 7.8 (Discharge) 6 23 2.5 67 3.8 DOC 0
0 29 53 17 6
0 0
0 0
64Cu 0
11 25 46 14 May 1980 (Discharge) 6 21 0.4 66 8.2 59Fe 0
3.3 5.1 59 24 6
0.9 0
1.3 52 DOC 0
15 1.6 19 64 6
0 0
0 0
64Cu 0
11 21 45 11 July 1980 (Discharge) 6 34 0
50 0
59 e 0
0.8 2.8 46 36 F
6 1
0 0
68 DOC 0
43 21 9.6 27 6
97 2.6 0
0 64Cu 0
9.4 11 64 9.2 July 1980 (Control) 6 18 5.9 69 0
59Fe 0
2 1.6 50 37 6
1.1 0
1.8 57 59Fe sorbed tests at Salem and Surry af ter UV oxidation (Ref. 5). The percent of or trapped on the membrane filter was 7.8 in untreated water and rose to 38 after UV oxidation. This increase indicates the presence of large inorganic iron complexes that occur after the organic matter is destroyed. The acid wash 59 recovery of Fe remained low following UV treatment.
It is well established that copper may exist in a number of chemical and physical forms. In Table 9, the chemical forms are related to molecular size. One reaction that may occur is the formation of colloids; these are generally greater than 100,000 in molecular weight. Another reaction is the sorption of one metal to 19 l
1 64Cu and 59Fe recovered in the dissolved (filtrate plus the Table 8. Percentages of solution remaining in the ultrafiltration cell) and sorbed (to the walls and membrane) fractions of the ultrafiltered water.
Collection date and UV treatment Dissolved Sorbed fraction location Analysis (h) fraction Membrane Walf Nov.1979 64Cu 0
95 3
2 6
96 2
2 (Discharge) 64Cu O
96 3
1 May 1980 (Discharge) 6 96 2
2 59 e 0
92 6
2 F
6 54 45 1
64Cu O
89 4
7 July 1980
^
(Discharge) 6 84 5
11 59Fe 0
86 11 3
6 69 29 2
64Cu O
94 4
2 July 1980 (Control) 6 94 2
4 59Fe 0
91 6
3 f
6 60 39 1
colloids of other metals. In this study, we found that UV treatment resulted in an 59 e but not of 64Cu in the > 100,000 MWF. Tnis reaction of copper increase of F
was different from that observed in water from other power stations (Refs. 4, 5, i
~
15). The behavior of the 64Cu-tagged copper at H.B. Robinson may be related to the lower pH of the water. It does not appear to be related to the operation of the power station because in water from the control site collected in July 1980, the l
behavior of 64Cu and 59Fe before and after UV treatment was similar to that the discharge area collected in May and July 1980. That is, observed in water frogFe in the > 100,000 MWF increased greatly, whereas the the percentage of 64 percentage of Cu remained greatest in the > 10,000, < 100,000 MWF.
The fraction of 59Fe sorbed on the membrane increased following UV treatment.
s Increases in this fraction indicate changes in physicochemical forms of the iron j
when the organic matter, which contains important binding sites, has been removed. The increase in sorbed fraction is most likely a result of large inorganic complexes that may be retained in the pores of the membrane.
(
'Most researchers agree that organic ligands form complexes and chelates with copper that affect transport and availability in natural waters (Refs. 43-45). Two mechanisms by which organic compounds can solubilize metals are (1) by forming l
20 l
1 1
1 I
t l
l l
l Table 9. Chemical species of copper.a Filterable Precipitates, inorganic ion Organic Metal species bound Metal species in the organic particles, Free pairs, inorganic complexes, to high molecular-form of highly Metal species sorbed remains of metal ions complexes chelates weight organic material dispersed colloids on colloids living organisms 2
b Cu-SR Cu-lipids Cu(OH) -Me(OH)n u(OH)n, CuCO,
Cu + (aq.)
Cu (OH)y*
3 2
Cu-OOCR Cu-humic-acid CuS,etc.on CuCO3 N
polymers clays Gelbstoffe Cu-polysaccharides Ultrafiltration diameter range: -
12 A 15 A 52 A 1,000 A Molecular weight: <1,000
>I,000,
> 10,000,
<!O,000
< 100,000
> 100,000 a Modified from Stumm and Braun-V ef. 42).
b R = organic ligand.
1 metal-ligand complexes with sorption characteristics different from those of the free-metal ion, or (2) by solubilizing the iron and manganese oxides and thus releasing sorbed trace metals (Ref. 45). Humic substances form an important group of dissolved organic material, which includes refractory organic molecules that constitute approximately 90% of the dissolved organic material in seawater.
i Humic substances are classified by solubility and references are usually to two classes humic acid, which is soluble in base and insoluble in acid, and fulvic acid, which is soluble in both base and acid. The molecules consist of long carbon chains; complex aromatic structures (Ref. 46); and oxygen, nitrogen, sulphur, and phosphorus functional groups such as the aromatic amine (-N:) and carboxylate
(-CO-) groups. Humic substances may scavenge copper lons and thus play a major role in its physicochemical transformation.
Several researchers have investigated the MWFs of aquatic humus by ultrafiltration (Refs. 47, 48). Allen studied some of the ecological implications of dissolved organic matter after fractionating lake water into molecular weight compartments 2
(Ref. 49). Giesy and Briese have extensively studied various metal associations of naturally occurring, aquatic organic fractions (Ref. 48). Smith determined the copper complexation capacities of various MWFs of dissolved organic matter in estuarine waters by a combination of ultrafiltration and anodic stripping voltammetry techniques (Ref. 30). Laxen and Harrison studied the concentration and size distribution of different species of copper in effluent from sewage disposal plants using filtration, anodic stripping voltammetry, and Chelex-100 lon exchange resin; 5cy concluded that interactions with organics are important in copper speciat.on patterns (Ref. 41).
i The source and nature of the organic matter associated with the copper are as yet l
unresolved. Organic compounds may be excreted by aquatic organisms, may arise from the decomposition of dead organism 3, or may be introduced in freshwater runoff. Foster and Morris suggest that concentrations of organic-bound copper in seawater result at least partially from active marine production of organic matter (Ref. 50).
l The variation of DOC in water samples from Salem and Surry was small (2.2 to 5.1 mg C/L) compared with the variation in ACC (4 to 60 pg Cu/L). More data are required before sources of seasonal variation can be identified.
We determined the concentrations of some elements as well as anions in the soluble fraction of water collected in May and July 1980 (Tables 10 and 11). Chloride and sulfate were the predominant anions. Only copper, zinc, and calcium were consistently higher in the intake and discharge areas than in the control area.
BEDLOAD SEDIMENTS Copper Concentrations Copper concentrations in intact bedload sediments from the intake and discharge areas were considerably higher than those from the control area (Table 12). Some of the highest concentrations were determined in sediment from the intake area.
In all of the samples collected, the copper concentrations in the <62 ym fractions were generally higher than those in the intac t sediments.
22
Table 10. Concentrations of soluble elements (pg/L) in water collected at the H.B.
Robinson Steam Electric Plant.
May 1980 July 1980 Element intake Discharge Control intake Discharge Control Downstream i
11 til Al 99 92 81
<!6 24 74 27 61 139 As
<40
<40
<40
<100
<100
<100
<100
<100
<100 B
8 8
9a
<!2
<12
<12 12
<12 45 Cd
<1
<l
<1
<3
<3
<3
<3
<3
<3 Co
<4
<4
<4
<6
<6
<6
<6
<6
<6 Cu 24 32 2
20 21
<2 9
17 9
Fe 96 58 54 66 63 120 97 46 206 Li
< 0.4
< 0.4
< 0.4
<0.4
< 0.4
< 0.4
<0.4 1
3 Mn 25 23 18 11 11 11 9
20 36 Mo
<10
<10
<10
<ll
<ll
<ll
<ll
<ll Ni
<1 2a 3a
<jg
<g4
<gg
<34
<gg
<g4 P
<!30
<!30
<130
<82
<82
<82
<82
<82
<82 Pb
<20
<20
<20
<22
<22
<22
<22
<22
<22 Se
<70
<70
<70
<60
<60
<60
<60
<60
<60 3
Si 1,000 1,100 890 1,200 1,300 2,000 830 1,500 1,300 Sr 9a 6a ya 6
7
<3 9
11 21 Ti
<1
<l
<1
<1
<1
<1
<1
<1
<1 V
<3
<3
<3
<2
<2
<2
<2
<2 3
Zn 19 19 11 28 52
<6 20 20 65 Ca 6,000 7,900 650 1,500 1,600 530 1,400 1,100 2,900 K
490 490 440 380 410 250 670 440 1,100 Mg 350 490 410 450 430 330 670 510 740 Na 1,700 1,700 1,500 1,600 1,600 1,200 3,500 2,000 13,000 a Fractional standar<l deviation = 0.25.
l j
Large differences with sampling time were found in the copper concentrations in interstitial waters; the highest concentrations were observed in July. These differences may be related to oxidizing and reducing states of the sediments. The characteristics of the sediments differed with sampling site; differences were observed in the color, Eh, and pH of the sediments (Table 13).
Considerable controversary exists about the application of Eh measuremerits. It is usually accepted that Eh is an index of oxidizing or reducing conditions but cannot be used to demonstrate the presence or absence of oxygen (Ref. 51). It is apparent from the measurements taken that both oxidizing and reducing conditions were present. However, it is not known whether these are the function of the biologica!
consumption of oxygen or the amount of soluble iron and microbial-gen ~ rated hydrogen sulfide. Regardless of the cause of the change in potential, it ca? be expected that the physicochemical form of the copper will differ under oxidizing l
and reducing conditions.
23
i Table i1. Concentrations of anions (pg/L) in water collected near the H.B.
Robinson Steam Electric Plant.
May 1980 July 1980 lon intake Discharge Control Intake Discharge Control F'I s 70 s 50 s 50 50 150 100 Cl'I 2000 1800 1730 2300 2400 1800 N O' N D" ND ND ND ND ND 2
PO[3 ND ND ND ND ND ND 2
l Br'I ND ND ND ND ND ND l
NO}I ND ND ND ND 430 220 l
SOj2 3200 4000 1200 4000 7900 1400 I
i a Not detected.
1 Distribution Coefficients The copper K s of intact bedload sediments collected from the different sites in y
the intake, discharge, and control areas differed with area and sampling time I
(Table 14). The K s were usually higher in the <62-um fraction than in intact d
sediments. Considerabia heterogeneity of K s was found at all sampling areas.
d The iron K s of the bedload sediments were also determined.
The K s for iron d
q were always higher than those for copper (Table 14).
Information on copper K s is limited to that which we obtained at other power 4
d stations. The Kgs of intact sediments from the discharge area of the San Onofre Nuclear Power Station ranged from 50 to 400 and those from Diablo Canyon from 50 to 570 (Ref. 6). These are much lower values than the 3,800 to 48,000 determined for intact sediments from the discharge area at Surry and the 250 to 33,000 for the comparable area at Salem.
Particle Size Distribution, Carbon Content, and Mineral Composition Selected sediment samples were analyzed for particle size distribution, organic carbon, and calcium carbonate (Table 15). Sediment from the discharge area appeared to be high in organic carbon. The mineral composition was determined with a combination of microscope examination and x-ray diffraction. Quartz predominated in all samples, although the intake sediments contained some mica and some of the downstream sediments contained a small amount of steel-mill slag (gehlinite-akermainte).
24
Table 12. Copper concentrations in bedload sediments bg/g dry weight) collected at the H.B. Robinson Steam Electric Plant.
Collection date and site Collection November 1979 May 1980 July 1980 area Component Site 1 Site 2 Site i Site 2 Site 1 Site 2 Intake Intact sediments 5.8 4.4 260 185 181 183 0.13a Interstitial water 21 26
<62-pm fraction 65a 252 180 314a Discharge Intact sediments 34 6.1 33 46 72 68 1.29a Interstitial water 2290 86
<62-pm fraction 822a 105 112 575a Control Intact sediments 3.7 1.3 0.9 0.9 0.6 05 0.14a Interstitial water 71 38
<62-pm fraction 27a 24 25 Sa Downstream 11.6 1
Intact sediments 145 b
Interstitial water 5.4 11 Intact sediments 162 0.16 Interstitial water 24 III Intact sediments 0.02 Interstitial water a Composite sample.
b Too sandy to collect interstitial water.
25
1 Table 13. Characteristics of sediments collected at the H.B. Robinson Steam Electric Plant.
i Collection Collection Characteristics date area Sites Eh,pH Comments 1
Light tan, sandy with Nov.1979 Intake 1,2 white chalk inclusions Brown, sandy Discharge 1
Black, sandy with orgame j
2
+
material present i
Control 1,2 Brown, sandy with organic material present May 1980 Intake Eh, -50; pH, 4.7 Tan, sandy 2
Eh, -60; pH, 4.6 Discharge 1
Eh, +60; pH, 4 Gray, sandy with numerous black 2
Eh, +65; pH 4 particles i
Control 1
Eh, +10; pH,4.)
Gray, sandy with small i
2 Eh, +30; pH, 4.5 amount of organic material July 1980 Intake 1
Eh, -210 Fine clay, gray-brown 2
Eh, -110 with light gray inclusions Discharge Eh, -160 Fine clay, s 50% sand 2
Eh, -80 with small amount of organic material Control I
tih, +60 Gray, sandy with s 5%
2 Eh, +50 black organic material
)
Downstream I
Eh, +10 Coarse sand, very hard i
packed 11 Eh, -10 Sandy til Eh, -260 Oily, sulphur smell 4
26
Table 14. Distribution coefficients for bedload sediments collected at the H.B. Robinson Steam Electric Plant.
Collection Collection intake Discharge Control date site Intact <62 pm Intact < 62 pm Intact
<62 pm Copper Nov.1979 1
810 2,000 400 8,900 3,900 8,200 2
1,800 2,600 300 25,000 400 15,000 3
800 1,000 300 12,000 600 8,400 May 1980 1
9,500 9,800 10,000 23,800 900 16,000 2
12,000 11,000 21,000 54,000 400 8,100 July 1980 1
4,700 6,400 800 10,000 100 1,800 2
4,200 7,500 600 12,000 80 3,700 Iron May 1980 1
19,000 20,000 10,000 39,000 2,600 29,000 2
19,000 21,000 44,000 83,000 1,300 26,000 July 1980 1
11,000 18,000 2,300 17,000 600 9,400 2
11,000 13,000 1,700 21,000 410 19,000 27
Table 15. Particle size distribution, organic carbon, calcium carbonate, and mineral content of intact bedload sediments collected from the H.B. Robinson Steam Electric Plant, July 1980.
Particle type (%)a Collection Gravel-Silt Clay Organic Calcium Mineral b
site sand carbon (%)a carbonate (%)a content Intake 24.2 65.1 10.7 3.9 negligible
- quartz, mica 25.6 0.62
- quartz, Discharge 93.7 6.3 muscoite 0.9 negligible quartz Control 96.7 3.3 Downstream c
I 98.8 1.2 1.5 0.12 quartz 0.13 negligible quartz II 99.4 0.6 111 98 2
1.1 negligible quartz a Analyses performed by Dr. D. S. Gorsline, Department of Geological Sciences, University of Southern California, California, b Analyses performed by Dr. A. Colville, Department of Geology, California State University at Los Angeles, California.
c Gehlinite-akermainte, possibly steel-mill slag.
l l
l 28 l
1 l
REFERENCES 1.
F. L. Harrison, " Effects of Copper Speciation on Aquatic Ecosystems,"
Carolina Power and Light, Electric Power Research Institute, Raleigh, NC, Mar. 23-24,1982.
2.
J. W. Warrick, S. G. Sharp, and S. J. Friedrick, " Chemical, Biological, and Corrosion Investigations Related to the Testing of the Diablo Canyon Unit I Cooling Water System," Pacific Gas and Electric Co.,
Department of Engineering Research, San Ramon, CA, report 7333,1975, p.129.
3.
D. R. Young, T.-K. Jan, and T. C. Heesen, " Cycling of T: 'ce Metal and Chlorinated Hydrocarbon Wastes in the South California Bight " pp. 481-496, in Estuarine Interactions. Fourth Biannual Estuarine Research Conference, Mt. Pocano, PA, Oct. 2-5,1977, M. L. Wiley, Ed. (Academic Press, Inc., NY, 1973).
4.
F. L. Harrison, D. J. Bishop, R.
R.
Emerson, and D.
W.
- Rice, Jr.,
" Concentration and Speciation of Copper in Waters Collected Near the San Onofre and Diablo Canyon Nuclear Power Stations," Lawrence Livermore National Laboratory, U.S. Nuclear Regulatory Commission, Livermore, CA, NUREG CR/0750, UCRL-52706,1980.
5.
F. L. Harrison, D. J. Bishop, D. W. Rice, Jr., and J. P. Knezovich, " Copper in the Intake and Discharge Zones of the Surry and Salem Nuclear Power Stations," Lawrence Livermore National Laboratory, U.S. Nuclear Regulatory Commission, Livermore, CA, NUREG/CR-2965, UCRL-53325,1983.
6.
R.
R.
Emerson and F.
L.
Harrison, " Copper Distribution in Abiotic Compartments of Aquatic Ecosystems Near the Diablo Canyon and San Onofre Nuclear Power Stations," Lawrence Livermore National Laboratory, U.S. Nuclear Regulatory Commission, Livermore, CA, NUREG/CR-1090, UCRL-52555,1981.
7.
D. G. Waslenchuk, "The Concentration, Reactivity, and Fate of Copper, Nickel, and Zinc Associated with a Cooling Water Plume in Estuarine Waters," Environmental Pollution (Series B) 3, 271-287 (1982).
8.
M. D. Stephenson, M. Martin, and J. H. Martin, " Copper Toxicity Experiments in Relation to Abalone Deaths Observed in a Power Plant's Cooling Waters,"
California Fish and Game 63(2),95-100 (1977).
9.
T. M. Florence and G. E. Batley, " Determination of the Chemical Forms of Trace Metals in Natural Waters, with Special Reference to Copper, Lead, Cadmium, and Zinc," Talanta 23,151-158 (1977).
10.
S. F. Sugai and M. L. Healy, "Voltammetric Studies of the Organic Association of Copper and Lead in Two Canadian Inlets," Marine Chemistry 6, 29l-308 (1978).
I 1.
J. P. Riley and D. Taylor, " Chelating Resins for the Concentration of Trace Elements from Sea Water and Their Analytical Use in Conjunction with Atomic Absorption Spectrophotometry," Analytica Chimica Acta 40, 479-487 (1968).
29 l
l 12.
Y. K. Chau, R. Gachter, and L. S. Chan, " Determination of the Apparent Complexing Capacity of Lake Waters," Journal of the Fisheries Research Board of Canada 31, 1515 (1974).
13.
J. D. H. Strickland and T. R. Parsons, A Practical Handbook of Seawater Analysis, Fisheries Research Board of Canada, Ottowa, Canada,1962.
I 4.
B. J. Ward, Carolina Power and Light Cornpany, New Hill, NC, letter to F. L. Harrison, LLNL,
Subject:
manuscript review, dated April 5,1983 15.
F. L. Harrison, D. J. Bishop, D. W. Rice, Jr., and J.
P. Knezovich,
" Concentration and Distribution of Copper in Effluents from Three Freshwater Nuclear Power Stations," Lawrence Livermore National Laboratory, U.S.
Nuclear Regulatory Commission, Livermore, CA, NUREG/CR-3358, UCRL-53482, in press.
16.
F. W. B. Bugenyi, " Copper Ion Distribution in the Surface Waters of Lakes George and Idd Amin," Hydrobiologia 64, 9-15 (1979).
17.
Carolina Power and Light Co., "H.B. Robinson Steam Electric Plant 1976-78 Environmental Monitoring Program Results," Carolina Power and Light Co.,
Florence, SC,1979, vol.1.
18.
P. Figura and B. McDuffie, " Determination of Labilities of Soluble Trace Metal Species in Environmental Samples by Anodic Stripping Voltammetry and Chelex Columns and Batch Methods," Analytical Chemistry 52, 1433-1439 (1980).
19.
T. A. Neubecker and H. E. Allen, "The Measurement of Complexation Capacity and Conditional Stability Constants for Ligands in Natural Waters,"
Water Research 17, 1-14 (1983).
20.
R. Kunkel and S. E. Manahan, " Atomic Absorption Analysis of Strong Heavy Metal Chelating Agents in Water and Waste Water," Analytical Chemistry 45, 1465-1468 (1973).
21.
P. G. C. Campbell, M. Bisson, R. Gagne, and A. Tessier, " Critical Evaluation of the Copper (11) Solubilization Method for the Determination of the Complexation Capacity of Natural Waters," Analytical Chemistry 49, 2358-2363 (1977).
22.
J. F. Elder, K.. E. Osborn, and C. R. Goldman, " Iron Transport in a Lake Tahoe Tributary and its Potential influence Upon Phytoplankton Growth," Water Research 10, 783-788(1976).
23.
R. A. Kerr and J. G. Quinn, " Chemical Comparison of Dissolved Organic Matter Isolated from Different Oceanic Environments," Marine Chemistry 8, 217-229 (l980).
24.
Y. Avnimelech and A. Raveh, " Decomposition of Chelate Leached from Waste Disposal Sites," Journal of Environmental Quality 11, 69-72 (1982).
25.
E. W. Davey, M. J. Morgan, and S. J. Erickson, "A Biological Measurement of the Copper Complexation Capacity of Seawater,"
Limnology and Oceanography I 8, 993-997 (1973).
30
l 26.
R. Gachter,3. S. Davis, and A. Mares, " Regulation of Copper Availability to Phytoplankton by Macromolecules in Lake Waters," Environmental Science and Technology 12, 1416-1421 (1978).
27.
P. A. Gillespie and R. F. Vaccaro, "A Bacterial Bioassay for Measuring the Copper Chelation Capacity of Seawater," Limnology and Oceanography 23, 543-548 (1978).
28.
Y. K. Chau, " Complexing Capacity of Natural Water-Its Significance and Measurement," Journal of Chromatographic Science 11, 579 (1973).
29.
T. A. O'Shea and K. H. Mancy, " Characterization of Trace Metal Organic Interactions by Anodic Stripping Voltammetry," Analytical Chemistry 48, I603-1607 (1976).
30.
R. G. Smith, " Evaluation of Combined Applications of Ultrafiltration and Complexation Capacity Techniques to Natural Waters," Analytical Chemistry 48, 74-76 (1976).
31.
- 3. C. Duinker and C. J. M. Kramer, "An Experimental Study on the Speciation of Dissolved Zinc, Cadmium, Lead, and Copper in the River Rhine and North Sea Water by Differential Pulsed Anodic Stripping Voltammetry," Marine Chemistry 5, 207-228 (1977).
32.
K. W. Hanck and J. W. Dillard, " Evaluation of Micromolar Compleximetric Titrations for the Determination of the Complexing Capacity of Natural Waters," Analytica Chimica Acta 89, 329-338 (1977).
33.
M. S. Shuman and J. L. Cromer, " Copper Association with Aquatic Fulvic and Humic Acids: Estimation of Conditional Formation Constants with a Titrimetric Anodic Stripping Voltammetry Procedure," Environmental Science and Technology 13, 543-545 (1979).
34.
C. M. G. Van den Berg, " Complexation of Copper in Natural Waters.
Determination of Complexing Capacities and Conditional Stability Constants in Natural Waters by MnO, and the implications for Phytoplankton Toxicity,"
2 Ph.D. Thesis, McMaster University, Hamilton, Ontario, Canada,1979.
35.
M.
R.
- Hoffmann, E.
C.
- Yost, S.
3.
Eisenreich, and W.
3.
- Maier,
" Characterization of Soluble and Colloid Phase Metal Complexes in River Water by Ultrafiltration. A Mass-Balance Approach," Environmental Science and Technology 15, 655-661 (1981).
36.
B. T. Hart and S. H. R. Davies, " Copper Complexing Capacity of Waters in the Magelan Creek System, Northern Australia," Environmental Technology Letters 2, 205-214 (1981).
37.
B. Lazar, A. Katz, and S. Ben-Yaakov, " Copper Complexing Capacity of Sea Water: A Critical Appraisal of the Direct Anodic Stripping Voltammetry,"
Marine Chemistry 10(3), 221-232(1981).
38.
C. M. G. Van den Berg and J. R. Kramer, " Determination of Complexing Capacities of Ligands in Natural Waters and Conditional Stability Constants of the Copper Complexes by Means of Manganese Dioxide," Analytica Chimica Acta 106, i13-120 (1979).
31
39.
S. Ramamoorthy and D. 3. Kushner, " Heavy Metal Binding Components of River Water," Journal of the Fisheries Research Board of Canada 32, 1755-1766 (1975).
40.
- 3. P. Giesy, Jr., L. A. Briese, and G. 3. Leversee, " Metal Binding Capacity of Selected Maine Surface Waters," Environmental Geology 2, 257-268 (1978).
41.
D. P. H. Laxen and R. M. Harrison, "A Scheme for the Physico-Chemical Speciation of Trace Metals in Freshwater Samples," Science of the Total Environment 19, 59-82 (1981).
l 42.
W. Stumm and P. A. Brauner, " Chemical Speciation," Chemical Oceanography 1, 173 (1975).
43.
E. A. Jenne, " Controls on Mn, Fe, Co, Ni, Cu, and Zn Concentrations in Soils and Water: The Significant Role of Hydrous Mn and Fe Oxides," in Advances in Chemistry Series (American Chemical Society, Washington, DC,1968),
No. 73, pp. 337-386.
i 44.
M. A. Rashid and 3. D. Leonard, " Modifications in the Solubility and Precipitation Behavior of Various Metals as a Result of Their Interaction with Sedimentary Humic Acid," Chemical Geology 11, 89 (1973).
45.
R. D. Guy, C. L. Chahrabarti, and L. L. Schramm, "The Application of a Sample Chemical Model of Natural Waters to Metal Fixation in Particulate Matter," Canadian Journal of Chemistry 53, 661-669 (1975).
46.
- 3. Cline, " Pathways and Interactions of Copper with Aquatic Sediments,"
Ph.D. Thesis, Michigan State University, East Lansing, Michigan,1974.
47.
E. T. Gjessing, " Gel and Ultra Membrane Filtration of Aquatic Humus: A Comparison of the Two Methods," Schweizerische Zeitschrif t fuer Hydrologie 35, 286-294 (1973).
48.
- 3. P. Giesy and L. A. Briese, " Metals Associated with Organic Carbon Extracted from Okefenokee Swamp Water," Chemical Geology 20, 109-120 (1977).
49.
H. S. Allen, " Dissolved Organic Matter in Lakewater: Characteristics of Molecular Weight Size Fractions and Ecological Implications," Oikos 27, 64-70 (1976).
50.
P. Foster and A. W. Morris, "The Seasonal Variation of Dissolved lonic and Organically Associated Copper in the Menai Straits," Deep-Sea Research 1S, 231-236 (1971).
31.
- 3. A. Novitsky, I. R. Scott, and P. E. Kepkay, " Effects of Iron, Sulfur, and Microbial Activity on Aerobic to Anaerobic Transitions in Marine Sediments,"
Geomicrobiology Journal 2, 211-223 (1981).
3AS/ad f 32
APPENDIX
A. PROCEDURE
FOR CLEANING SAMPLE CONTAINERS CONTAINERS OF < 10 pg Cu/L SAMPLES New polypropylene containers were filled with reagent-grade, concentrated HNO3 and stored at room temperature for at least 7 d to teach out metal contaminants.
The acid was then removed and the containers rinsed five times with doubly (glass-)
distilled water (DDW) and filled with 0.05% Ultrex HNOg in DDW Af ter at least
~
4 d, the dilute acid was discarded and the containers were rinsed five times with DDW and then stored filled with DDW un7il use.
CONTAINERS OF > 10 pg Cu/L SAMPLES New polypropylene containers were soaked for at least 2 d in a 2% MICRO bath.
The containers were removed from the bath, rinsed five times with DDW, drained, and stored in sealed plastic bags until use.
t 33
O.S. NUCLEAR REGUL ATORY COMMISSION (7 77)
BIBLIOGRAPHIC D ATA SHEET UCRL-53047 4 TITLE AN D SUBTITLE (Add Volume No., of worportate1
- 2. (Leave Diank)
Concentration and Distribution of Copper in Effluents from 3 RECIPIENT'S ACCESSION NO.
the H. B. Robinson Steam Electric Plant
- 7. AUTHOR (S)
- 5. D ATE REPORT COMPLE TED F.L. Harrison, D.J. Bishop, D.W. Rice, Jr., and J.P. Knezovic i voNT" Ivena January 1983
- 9. PERFORMING ORGANIZATION N AME AND MAILING ADDRESS (incluor 2,0 Code)
DATL REPORT ISSUED Lawrence Livermore National Laboratory voNTw l YEAR P.O. Box 5507, Mail Code L-453 August 1983 Livermore, CA 94550 s (t,-e manni 8 (Lesee blank)
- 12. SPONSORING ORGANIZATION NAME AND M AILING ADDRESS (inctuoe Zep Code)
Division of Health, Siting and Waste Management Office of Nuclear Regulatory Research ii. CONTR ACT NO.
U.S. Nuclear Regulatory Conmission Washington, D.C.
20555 A0119
- 13. TYPE OF REPORT I PE RIOD CCV E RE D (inclusive dates)
Topical
- 15. SUPPLEMENTARY NOTES
- 14. (Leave blan*/
- 16. ABSTR ACT Q00 wceds or less)
Water and bedload sediments were sampled at the intake and discharge areas of the H. B. Robinson Steam Electric Plant and at a control area upstream of the plant in November 1979 and May and July 1980.
Total copper concentrations in discharge waters ranged from 33 to 79 ug/L, whereas those in intake waters ranged from 27 to 58 ug/L; copper in the water in the control area ranged from 3.1 to 5.8 ug/L.
In most samples, copper in the soluble fraction appeared equally as labile and bound. The concentration of dissolved organic carbon in the water samples from the impoundment area showed little variation with time; the values range from 3.8 to 5.7 mg C/L.
The organic carbon in the particulate fraction was 51 mg C/L.
Determination of molecular size distribution of the copper species by ultrafiltration of discharge and control waters indicated that the largest concentration of copper appeared in the >10,000, <100,000 molecular weight fraction both in untreated and UV-oxidized water.
Copper concentrations in intact bedload sediments of the intake area ranged from 4.4 to 260 ug/g dry weight; those in the discha ge area ranged from 6.1 to 72 pg/g. Copper in the upstream sediments was very low, 5 7 ug/g.
Higher concentrations appeared in the <62-um fractions than in 3
intact sediments. Copper distribution coefficients of intact bedlOad sediments in the intake and discharge areas ranged from 300 to 21,000.
- 17. KEY WoRDS AND DOCUMENT AN ALYSIS 17a. DESCRIPTORS copper, copper speciation, nuclear power station, effluents, toxicity, sediments, corrosion products 17b. IDENTIFIERSIOPEN ENDED TERMS
- 18. AV AILABILITY STATEMENT
- 19. SECURITY CLASS (This report)
- 21. NO. OF PAGES UNCLASSIFIED UNLIMITED 2o. SECuRiry CLASS (This page)
- 22. PRICE UNCLASSI FIED s
Nf.C FORM 335 (7 77)
UNITED STATES 2
5ou era ct ass wart 96UCLEAR REGULATORY COMMISSION P057^'jg llI5D k
S WASHtNGTON, D.C. 2TE6 aasa o c Mi n euir =. ut Q
0,3 orriciAt susisEss PfNALTY FOR PRIVATE USE 4300 6C w
12055bO7o877 1 1 Aidiht US NkL AOM-D1V UF 11OC POLICY
- t. PdB Mbi Bh-PDk fedklG W ' O1 LL 205L5
)
B R
$5
- e I
Ee m3 kk R ::
1m 55'z
?
8
- - - _ - _ _ _ _ _