PLANT OPERATIONS MANUAL g

t h

volume 05 05-1-02-11-2 Section 02 Revision:

10 Date: 3-19-82 j

OFF-NORMAL EVENT PROCEDURE OFF GAS ACTIVITY HIGH SAFETY RELATED

?

Prepared:

e

(

Reviewed:

/

Nuclear Planul Qualit/ Superintendent V Tei:hnical Review Reviewed:

Mh Operati s Su erintendent Approved:

M, 1t

/>

PSRC:

/_

/*

3 p

~

y

(--

i List of Ef fective Pages:

I Page:

Revis ion:

1-2 10 b-8206300254 820625 PDR ADOCK 05000416 P

PDR

r

... ~. -...

,.5_

e e

.ss GRAND GULF NUCLEAR STATION OFF-NORMAL EVENT PROCEDURE l

Title:

Of f Cas Activity High lNo.:

05-1-02-11-2 l Revision: 10 iPage: 1 1

l l

l l

l 1.0 PURPOSE / DISCUSSION 1.1 To provide instructions to the operator in the event of high or increasing activity La the Of f Gas System.

1.2 This procedure may interface with the Emergency Plan.

1.3 Condenser off gas high radiation may be indicative of a fuel element failure and fission product release. This procedure covers the period

}

from the discovery of an increasing Off Gas Activity, to the entrance into the emergency plan and a resulting plant shutdown if necessary.

j 2.0 SYMPTOMS 2.1 Increasing activity in the reactor vessel water samples.

2.2 Increasing main steam line radiation monitor readings.

r#

2.3 Increasing off gas pretreatment radiation monitor readings.

2.4 Increasing off gas post-treatment radiation monitor readings.

2.5 Annunciators,. High or High-High, on any of the above monitors.

3.0 AUTOMATIC ACTIONS

~

~

~

3.1 If the main steam line radiation monitor reaches 2.5 times normal background, the reactor will scram and a Group I isolation will occur.

3.2 If the of f gas post-treatment radiation monitor reaches the High-High-High setpoint, the following valves will close, isolating the off gas train:

3.2.1 IN64-FV-ET)60, OFF GAS DISCHARGE TO VENT.

3.2.2 F054, PREFILTER INLET DRAIN.

i 3.2.3 F034A(B), CONDENSER DRAIN.

3.2.4 F023, HOLDUP LINE DRAIN.

4.0 IMMEDIATE OPERATOR ACTIONS 4.1 Verify the appropriate automatic actions have occurred.

4.2 If the reactor scrammed, carry out actions of ONEP 05-1-02-1-1, Reactor Scram.

If MSIV closure occurred, enter EP-1, Level Control.

b

.