W TY/W

. p g E G m G io.no,inc.

ez//v/77

,.o.

.,e2s i

idano Falls. Idaho 83401 FEB 2 21977

/

[r.J)f [ 4 Mr. P. E. Litteneter, Chief l

Reactor Safety Behavior Branch If[C Idaho Operations Office - ERDA Idaho Falls, Idaho 83401 I

REVIEW OF RABCOCK AND WILC0X SYSTEM OPERATING SEQUEMCE DIAGRAMS AND FAILURE 10 DES AMD EFFECTS ANALYSES AS DOCUMENTED IK Tile STANDARD PLANT SAO, B-SAR-205 -

(A6025) - Stig-62-77

Dear Mr. Litteneker:

Transmitted herewith for your information is the inforeal letter report dealing with a review of the System Operating Sequence Diagrams and Failure Modes and Effects Analyses as documented in the Standard Plant safety Analysis Report.

B-SAR-205. Transmittal of the attached letter completes the task identified by PERT node F-3 of the A6025 (I-469) PERT schedule, entitled "B-SAR-205 EA Review".

Very truly yours.__

Original Signed By:

R. R. Stiner, Manager Reactor Behavior Division AJ0:srw

Attachment:

Subject Letter Report cc:

R. W. Kiehn, EG89 Idaho T. D. Knight, ERDA-ID G. R. Hazetis, NRC-DSS X. M. Novak, NRC-DSS D. F. Ross, NRC-DSS i